JWS508 Series
Single Output Industrial Power Supplies
Features
u
5 Year Warranty
u
Power factor Corrected
u
Approved to UL508
u
Universal Input (85 - 265VAC)
u
200% Peak power capable (JWS-P models)
u
Level B EMI
Key Market Segments & Applications
u
Factory Automation Process Control, NC-Machining,
Automotive, Packaging Equipment,
Chemical Processing, Robots
Not recommended for new designs - see HWS series
Specifications
Model
Input Voltage range
Inrush Current (100 / 200VAC)
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Current (max)
Remote Sense
Remote On / Off
AC Power Fail
Parallel Connection
Operating Temperature
Storage Temperature
Operating Humidity
(1)
Storage Humidity
(1)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated
Weight (Typ)
Recommended EMI Filter
Size (WxHxD)
Cover
Warranty
(1) Non condensing
JWS70P
JWS120P
JWS240P
JWS480P
JWS50
JWS75
JWS100
JWS150
JWS300
JWS600
85 - 265VAC (47 - 63Hz) or 120 - 330VDC (no DC input on JWS-P)
14 / 28
25 / 50
20 / 40
Meets EN61000-3-2
<0.02%/°C
>105%
Yes
20
0.75
No
Yes
Not Available
Standard
Not Available
Standard
Not Available
Avail. JWS300 & 600 only
See derating table
-30 to +85°C
30 - 90% RH (10 - 90% RH on JWS300 & 600 only)
10 - 95% RH
JWS50 - JWS150 Convection, JWS240 - JWS600 Internal fan
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA)
Output to Ground 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL508
EN55011 / EN55022-B, FCC Class B, VCCI-B
400
500
700
900
1900
3000
MAW1202-22
MAW1202-22 MAW1205-22
MB1210
MAW1203-22
MB1210
MB1216
See sheet 2
Standard
Five Years
-
A
-
-
-
V
ms
mA
-
-
-
-
-
°C
-
-
-
-
-
-
-
-
EMI
g
-
mm
-
-
1-800-526-2324 • www.us.tdk-lambda.com/lp/
11
Disclaimer: us.tdk-lambda.com/lp/legal.htm
JWS508 Series
Model Codes
1 CaseSelector
Code
CA1500
Model
Wattage
1500
Max Slots
8
Voltage
Max
Avg.
Peak
Load
2.5” x 8” x 11”
150 - 264VAC
Adjustment Range Current Current Current Reg mV
-
3
-
-
5
-
10
-
20
-
-
6
-
-
10
-
20
-
40
-
150
192
150
150
192
150
192
144
192
144
Size (H x W x L)
Input Voltage
Line
Reg mV
96
96
96
96
96
96
96
96
96
96
Ripple
Noise mV
150
240
150
150
240
150
240
150
240
150
Efficiency
(typ) %
79
80
79
79
80
80
80
80
80
82
JWS50-24/508
24V
21.6 - 26.4
2.2
JWS70P-24/508
24V
21.6 - 26.4
-
JWS75-24/508
24V
21.6 - 26.4
3.2
JWS100-24/508
24V
21.6 - 26.4
4.5
JWS120P-24/508
24V
21.6 - 26.4
-
JWS150-24/508
24V
21.6 - 26.4
6.5
JWS240P-24/508
24V
21.6 - 28.8
-
JWS300-24/508
24V
21.6 - 28.8
14
JWS480P-24/508
24V
21.6 - 28.8
-
JWS600-24/508
24V
21.6 - 28.8
27
Note 1: Peak current for up to 10 seconds with a 50% duty cycle
Model Derating*
Model
40°C
45°C
50°C
55°C
60°C
-
60%
-
-
60%
-
70%
70%
70%
70%
65°C
-
-
-
-
-
-
55%
55%
55%
55%
JWS50-24/508
100% 100% 80%
60%
JWS70P-24/508
100% 100% 100%
80%
JWS75-24/508
100% 80%
60%
-
JWS100-24/508
100% 100% 100%
60%
JWS120P-24/508
100% 100% 100%
80%
JWS150-24/508
100% 100% 100%
60%
JWS240P-24/508
100% 100% 100%
85%
JWS300-24/508
100% 100% 100%
85%
JWS480P-24/508
100% 100% 100%
85%
JWS600-24/508
100% 100% 100%
85%
* % of full power rating at specified temperature
JWS Outline Drawing
W
H
FRONT VIEW
Dimensions Table
Height (H)
JWS50
JWS75
JWS70P, JWS100
JWS120P, JWS150
JWS240P, JWS300
JWS480P, JWS600
1.45”
1.65”
1.97”
2.56”
3.62”
3.62”
Width (W)
3.35”
3.62”
3.62”
3.62”
4.72”
6.29”
Depth (D)
6.25”
6.88”
7.40”
7.80”
7.48”
7.90”
H
(BOTH SIDES)
SIDE VIEW
Other Industrial Products
HWS
JWS, JWS-P & JWT
LZSa
JFS
DLP/DSP/DPP
15 to 1500W Single output
50 to 600W Single and triple output
500 to 1500W Single output
500 to 2000W Single output
10 to 480W DIN Rail Mount
MOUNTING SURFACE
W
D
For Additional Information, please visit
us.tdk-lambda.com/lp/products/jws-series.htm
See website for detailed drawing.
Not recommended for new designs - see HWS series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
12