Description
Isolated DC/DC Converters 66W 3.3V 20A
Categorysemiconductor    Power management   
File Size1MB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet Parametric View All

PH100S48-33 Online Shopping

Suppliers Part Number Price MOQ In stock  
PH100S48-33 - - View Buy Now

PH100S48-33 Overview

Isolated DC/DC Converters 66W 3.3V 20A

PH100S48-33 Parametric

Parameter NameAttribute value
Product CategoryIsolated DC/DC Converters
ManufacturerTDK Corporation
RoHSDetails
Number of Outputs1 Output
Output Power66 W
Input Voltage36 V to 76 V
Output Voltage-Channel 13.3 V
Output Current-Channel 120 A
Length2.44 in
Width3.38 in
Height0.5 in
PackagingTube
ProductIsolated
Factory Pack Quantity1
PH-S Series
Simple function, 50 to 600W DC-DC converters
Features
High Density
Wide Range Input
Output adjustment Capability
Remote On/Off
Fixed Switching Frequency
International Safety Approvals
Low component count
Key Market Segments & Applications
Specifications
Model
Input range
Output Voltage Adj. Range
Line Regulation
Load Regulation
Ripple and Noise
Series Operation
Over Voltage Protection
Overload Protection
Remote On/Off
Remote Sensing
Parallel operation
Inverter Good signal
Thermal Protection
Cooling
Operating Temperature Range
Storage Temperature
Temperature Coefficient
Isolation
Isolation Resistance
Safety Agency Certification (1)
Warranty
3.3V
5V
12V
15V
24V
28V
48V
VDC
24V nom: 18-36, 48V nom: 36-76V, 110V nom: 82-185V, 280V nom: 200-400V
VDC 2.97~3.63
4.5~5.5
10.8~13.2 13.5~16.5 21.6~26.4 25.2~30.8
43.2~52.8
-
0.4% or 20mV (whichever is greater) over entire input range with constant load
-
0.8% or 40mV (whichever is greater) from no load to full load with constant input line
pk-pk
100mV
150mV
240mV
280mV
480mV
-
Possible - Refer to installation manual
%
150 - 180%
125 - 145%
%
Approximately 105 - 140%, automatic recovery
-
Low = ON, Open = OFF
-
PH100S, PH150S, PH300S, PH600S models
-
PH300S & PH600S only: Requires external circuitry
-
PH300S & PH600S only: Signal available for status of inverter
-
Internal sensing, self resetting
-
Conduction or forced air. See application notes for cooling and heatsink selection
°C
Baseplate temperature -20°C to +85°C (100°C on PH300 & PH600).
-40°C start up possible - consult factory
°C
-40°C to +85°C (+100°C on PH300 & PH600)
-
0.02%/°C
-
Input to output: 3000VAC, Input to Baseplate: 2500VAC(1)
-
Output to Baseplate -100MOhm at 500VDC and 70%RH
-
UL60950-1, CSA60950-1, EN60950-1 and CE Mark.
yrs
Two years
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) No safety certification on PH50S48-3.3, PH75S48-3.3, PH150S48-3.3
Obsolete, except PH300S280 which
has a last time buy of June 2018
1-800-526-2324 • www.us.tdk-lambda.com/lp/
155
Disclaimer: us.tdk-lambda.com/lp/legal.htm

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号