EEWORLDEEWORLDEEWORLD

Part Number

Search

LDA100W-12-V

Description
DC Power Cords INPUT MATING HARNESS
CategoryPower/power management   
File Size1MB,17 Pages
ManufacturerCosel
Download Datasheet Parametric View All

LDA100W-12-V Online Shopping

Suppliers Part Number Price MOQ In stock  
LDA100W-12-V - - View Buy Now

LDA100W-12-V Overview

DC Power Cords INPUT MATING HARNESS

LDA100W-12-V Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 112 V
Number of Outputs1 Output
Output Power102 W
Open Frame/EnclosedOpen Frame
Input Voltage85 VAC to 132 VAC/170 VAC to 264 VAC
Output Current-Channel 18.5 A
Commercial/MedicalCommercial
Isolation Voltage3 kV
Mounting StyleChassis
Length222 mm
Width62 mm
Height35 mm
Input Frequency47 Hz to 440 Hz
Load RegulationRegulated
Factory Pack Quantity25
Unit Weight12.698626 oz
AC-DC Power Supplies Open Frame/Enclosed type
Ordering information
LDA10F
R
LDA
1
2
10
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*2
C :with Coating
G :Low leakage current
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LDA10F-3
6
3V 2.0A
LDA10F-5
10
5V 2.0A
LDA10F-12
10.8
12V 0.9A
LDA10F-15
10.5
15V 0.7A
LDA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
ACIN 200V
LDA10F-3
LDA10F-5
LDA10F-12
LDA10F-15
LDA10F-24
AC85 - 264 1
f
or DC110 - 370
0.25typ (Io=100%)
0.16typ (Io=100%)
47 - 440 or DC
68typ
72typ
74typ
74typ
78typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
12
15
24
2
2
0.9
0.7
0.5
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
50max
50max
120max
150max
240max
20max
20max
48max
60max
96max
200max (ACIN 100V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%)
2.85 - 3.6
Fixed ("Y"which can be adjusted the output is available as option :5, 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
50
X
21
X
105mm (W
X
H
X
D) /75g max (without chassis and cover)
Convection
LDA
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
ACIN 100V
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
TEMPERATURE REGULATION[mV]
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
INRUSH CURRENT[A]
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LDA-2
Ask a question about impedance testing
I would like to ask you a question. Can the impedance of a section of RF trace on a PCB be measured using a network analyzer? For example, look at S11 or S21? I hope you can give me some advice, thank...
huangwu RF/Wirelessly
Solution to the failure of IAR programming MSP430
[size=4]1. The failure condition is as follows:[/size] [size=4] [/size] [size=4] When the driver is installed correctly (the board is automatically installed when the USB is plugged in):[/size] [size=...
fish001 Microcontroller MCU
[Evaluation of EC-01F-Kit, the NB-IoT development board of Essence] 03. Discussion: Frequent disconnection after the device is connected to the network
[i=s]This post was last edited by Li Baiyi on 2021-12-22 21:11[/i]When debugging EC-01F MQTT to access Alibaba, the normal communication state is frequently disconnected and then automatically connect...
李百仪 RF/Wirelessly
If you use tweezers to short-circuit the output of a power supply, how many states will the load have?
At the moment the tweezers are short-circuited, the load becomes 0. At the moment the tweezers are released, the load changes from 0 back to its original value. Is this change process completed instan...
sfcsdc Analog electronics
Can a relay that switches on and off frequently be connected to a transformer?
I have a heating wire that is AC 70V, so I need a 220V to 70V transformer. The temperature control module is a relay output model, with a heating wire of 800W and a transformer of 3KVA. Now it is not ...
魔双月壁 Power technology
What tests need to be done before using power electronic products such as motor controllers after they have been stored for a long time?
Power electronic device integrated products, such as motor controllers, are stored for a long time (under non-strict storage conditions, such as humidity and temperature), and need to be used again. W...
zimiaoxinghan Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号