Features
Regulated
Converters
Description
•
•
•
•
•
•
2:1 Wide Input Voltage Range
1.6kVDC Isolation
UL Certified
Efficiency up to 91%
Six-Sided Continuous Shield
No Minimum Load Required
DC/DC Converter
RP30-F
30 Watt
3Y
wa
The RP30-F series DC/DC converters are designed to meet to UL 60950-1 and to cUL60950-1. This
makes them ideal for all telecom and industrial applications where approved safety standards are
required. The industry standard 2” x 1” package meets military standards for thermal shock and
vibration tolerance.
3
EAR
2“x1“Package
Single & Dual
Output
rranty
Selection Guide
Part Number
RP30-123.3SF
(3,4)
RP30-1205SF
(3,4)
RP30-1212SF
(3,4)
RP30-1215SF
(3,4)
RP30-243.3SF
(3,4)
RP30-2405SF
(3,4)
RP30-2412SF
(3,4)
RP30-2415SF
(3,4)
RP30-483.3SF
(3,4)
RP30-4805SF
(3,4)
RP30-4812SF
(3,4)
RP30-4815SF
(3,4)
RP30-1205DF
(3,4)
RP30-1212DF
(3,4)
RP30-1215DF
(3,4)
RP30-2405DF
(3,4)
RP30-2412DF
(3,4)
RP30-2415DF
(3,4)
RP30-4805DF
(3,4)
RP30-4812DF
(3,4)
RP30-4815DF
(3,4)
Input
Voltage Range
[VDC]
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
Output
Voltage
[VDC]
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
±5
±12
±15
±5
±12
±15
±5
±12
±15
Output
Current
[mA]
8000
6000
2500
2000
8000
6000
2500
2000
8000
6000
2500
2000
±3000
±1250
±1000
±3000
±1250
±1000
±3000
±1250
±1000
Input
(1)
Efficiency
(1)
Current
typ.
[mA]
[%]
2588
85
2874
87
2809
89
2809
89
1264
87
1389
90
1374
91
1374
91
632
87
694
90
687
91
687
91
2874
87
2874
87
2874
87
1389
90
1404
89
1389
90
694
90
710
88
702
89
Max. Capacitive
Load
(2)
[µF]
20000
14400
3000
2000
20000
14400
3000
2000
20000
14400
3000
2000
±3000
±2000
±1300
±3000
±2000
±1300
±3000
±2000
±1300
Notes:
Note1: Typical value at nominal input voltage and full load.
Note2: Test by minimum Vin and constant resistor load.
E196683
Model Numbering
UL60950-1 Certified
RP30-__ __ _F/_ _
Input Voltage
Output Voltage
Single
or
Dual
Ordering Examples
RP30-2405SF = 24V Input, 5V Output, Positive Logic CTRL pin fitted
RP30-4812DF/N-HC = 48V Input, ±12V Output, Negative Logic CTRL pin fitted, Heat-sink fitted
Package
(4)
Control Logic
(3)
Notes:
Note3: no suffix for CTRL function with Positive Logic (1=ON, 0=OFF)
add “N” for CTRL function with Negative Logic (0=ON, 1=OFF)
Note4: add suffix -HC for premounted Heat-sink and clips
www.recom-power.com
REV.: 2/2017
PD-1
RP30-F
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
BASIC CHARACTERISTICS
Parameter
Input Voltage Range
Series
Condition
nom. Vin = 12V
nom. Vin = 24V
nom. Vin = 48V
Vin = 12V
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Min.
9VDC
18VDC
36VDC
Typ.
12VDC
24VDC
48VDC
8VDC
Max.
18VDC
36VDC
75VDC
9VDC
18VDC
Under Voltage Lockout (UVLO)
Vin = 24V
Vin = 48V
16VDC
36VDC
32VDC
Pi-Type
20mAp-p
25VDC
50VDC
100VDC
30ms
30ms
387kHz
0%
430kHz
100mVp-p
150mVp-p
Open or 3.0V < Vr < 12V
Short or 0V < Vr < 1.2V
Short or 0V < Vr < 1.2V
Open or 3.0V < Vr < 12V
3mA
-0.5mA
0.5mA
473kHz
Input Filter
Input Reflected Ripple Current
(5)
Input Surge Voltage
Start-up time
Operating Frequency Range
Minimum Load
Ripple and Noise
measured by 20Mhz bandwidth 3.3Vout, 5Vout
with a 1µF/50V MLCC 12Vout, 15Vout
Positive Logic
Remote ON/OFF
(6)
Negative Logic
Input current of Remote pin (CTRL)
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
DC-DC OFF
DC-DC ON
nominal Vin and full load
Vin = 12V, 100ms max.
Vin = 24V, 100ms max.
Vin = 48V, 100ms max.
Power up
Remote ON/OFF
Notes:
Note5: Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
Note6: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin.
RP30-1205SF
Efficiency vs. Output Current
95
90
85
95
90
Efficiency vs. Input Voltage
Efficiency [%]
80
75
70
65
60
55
50
45
40
10
20
30
40
50
60
70
80
9Vin
12Vin
18Vin
90
100
Efficiency [%]
85
80
75
70
65
9
10
11
12
13
14
15
16
17
18
Output Current [%]
Input Voltage [VDC]
continued on next page
PD-2
REV.: 2/2017
www.recom-power.com
RP30-F
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP30-2405SF
95
90
85
90
80
75
70
65
60
55
50
45
40
10
20
30
40
50
60
70
80
18Vin
24Vin
36Vin
90
100
Series
Efficiency vs. Input Voltage
95
Efficiency vs. Output Current
Efficiency [%]
Efficiency [%]
85
80
75
70
65
18
20
22
24
26
28
30
32
34
36
Output Current [%]
Input Voltage [VDC]
RP30-4805SF
95
90
85
Efficiency vs. Output Current
95
90
Efficiency vs. Input Voltage
Efficiency [%]
80
75
70
65
60
55
50
45
40
10
20
30
40
50
60
70
80
36Vin
48Vin
75Vin
90
100
Efficiency [%]
85
80
75
70
65
36
40
44
48
52
56
60
64
68
72
75
Output Current [%]
Input Voltage [VDC]
REGULATIONS
Parameter
Output Voltage Accuracy
Voltage Adjustability
Line Voltage Regulation
Load Voltage Regulation
Cross Regulation
Transient Response recovery time
Single Output
low line to high line at full load
no load to full load
Single
Dual
Condition
Value
±1%
±10%
±0.2%
±0.5%
±1.0%
±5%
250µs
asymmetrical 25%<>100% load
25% load step change
External Output Trimming
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using
external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for
chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to
work out the resistor required or use a variable resistor to set the output voltage.
Output can be externally trimmed by using the method shown below.
Trim up
6
RU
5
4
6
Trim down
RD
continued on next page
www.recom-power.com
REV.: 2/2017
PD-3
RP30-F
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP30-xx3.3SF
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
1
3.333
57.93
1
3.267
69.47
1
5.05
36.57
1
4.95
45.53
2
3.366
26.16
2
3.234
31.23
2
5.10
16.58
2
4.90
20.61
3
3.399
15.58
3
3.201
18.49
3
5.15
9.92
3
4.85
12.31
4
3.432
10.28
4
3.168
12.12
4
5.20
6.58
4
4.80
8.15
5
3.465
7.11
5
3.135
8.29
5
5.25
4.59
5
4.75
5.66
6
3.498
4.99
6
3.102
5.74
6
5.30
3.25
6
4.70
4.00
7
3.531
3.48
7
3.069
3.92
7
5.35
2.30
7
4.65
2.81
8
3.564
2.34
8
3.036
2.56
8
5.4
1.59
8
4.60
1.92
9
3.597
1.46
9
3.003
1.50
9
5.45
1.03
9
4.55
1.23
10
3.63
0.75
10
2.97
0.65
10
5.50
0.59
10
4.50
0.68
%
Volts
kOhms
%
Volts
kOhms
%
Volts
kOhms
%
Volts
kOhms
Series
RP30-xx05SF
RP30-xx12SF
1
12.12
367.91
1
11.88
460.99
2
12.24
165.95
2
11.76
207.95
3
12.36
98.64
3
11.64
123.60
4
12.48
64.98
4
11.52
81.42
5
12.60
44.78
5
11.40
56.12
6
12.72
31.32
6
11.28
39.25
7
12.84
21.70
7
11.16
27.20
8
12.96
14.49
8
11.04
18.16
9
13.08
8.88
9
10.92
11.13
10
13.20
4.39
10
10.8
5.51
%
Volts
kOhms
%
Volts
kOhms
RP30-xx15SF
Trim up
Vout =
R
U
=
Trim down
Vout =
R
D
=
1
15.15
404.18
1
14.85
499.82
2
15.3
180.59
2
14.70
223.41
3
15.45
106.06
3
14.55
131.27
4
15.60
68.80
4
14.40
85.20
5
15.75
46.44
5
14.25
57.56
6
15.90
31.53
6
14.10
39.14
7
16.05
20.88
7
13.95
25.97
8
16.20
12.90
8
13.80
16.10
9
16.35
6.69
9
13.65
8.42
10
16.50
1.72
10
13.50
2.282
%
Volts
kOhms
%
Volts
kOhms
PROTECTIONS
Parameter
Short Circuit Protection (SCP)
3.3Vout
5Vout
Zener Diode Clamp
12Vout
15Vout
% of Iout rated
I/P to O/P
I/P to O/P to case
500VDC
Notes:
Note8: This power module is not internally fused. An input line fuse must always be used.
PD-4
REV.: 2/2017
www.recom-power.com
Condition
Value
Continuous, automatic recovery
3.9VDC
6.2VDC
15VDC
18VDC
150% typ.
115°C typ.
1.6kVDC/1 minute
1.6kVDC/1 minute
1GΩ min.
1500pF max.
Over Voltage Protection (OVP)
Over Load Protection (OLP)
Over Temperature Protection (OTP)
Isolation Voltage
Isolation Resistance
Isolation Capacitance
RP30-F
DC/DC Converter
Specifications
measured at Ta = 25°C, nominal input voltage, full load otherwise noted
ENVIRONMENTAL
Parameter
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Humidity
Thermal Shock
Vibration
MTBF
MIL-HDBK-217F
Bellcore TR-NWT-000332
(9)
RP30-2415SF
100
80
60
40
20
0
-40
Series
Condition
without derating
with derating
Value
-40°C o +74°C
-40°C to +97°C
+105°C
±0.02%/°C max.
Natural convection (20LFM)
Natural convection (20LFM) with Heat-sink
12°C/Watt
10°C/Watt
5% - 95% RH
MIL-STD-810F
MIL-STD-810F
1453 x 10
3
hours
3173 x 10
3
hours
Derating Graph
(10)
100
80
60
40
20
0
-40
RP30-2415SF with Heat-sink
Output Power [%]
-20
0
20
40
60
Ambient Temperature [°C]
74
80
100 120
97
Output Power [%]
-20
0
20
40
60
Ambient Temperature [°C]
75
80
100 120
97
Notes:
Note9: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment)
MIL-HDBK-217F Notice2 @ TA= 25°C, Full load (Ground, Benign, controlled environment)
Note10:Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
UL General Safety
Report / File Number
E196683
Standard
UL60950-1 1st. Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
EMC Compliance
EMI Standard
(11)
ESD
Radiated Immunity
Fast Transient
(12)
Surge
(12)
Conducted Immunity
Condition
with external filter
Air ±8kV and Contact ±6kC
10 V/m
±2kV
±1kV
10 Vr.m.s
continued on next page
Standard / Criterion
EN55022, Class A or B
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
www.recom-power.com
REV.: 2/2017
PD-5