Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to -IN voltage
PC to -IN voltage
PR to -IN voltage
SC to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24C12T100BL2
24C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
V
OUT
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
B
Output Power
P
OUT
75W, 50W
125W, 100W, 50W
100W
150W, 100W, 50W
150W, 100W, 50W
150W,100W, 50W
150W, 100W, 50W
100W, 50W
150W, 100W, 50W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
24V Micro Family
Page 1 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Modules will operate to 16V
IN
after startup at >17.9V.
Below 18V, available power is reduced to 75% of max
rating.
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% /°C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Micro Family
Page 2 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20 ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30
Ω,
<30 pF
PC current = 1.0 mA
PC voltage = 5.5 V
Switch must be able to sink
≥4
mA. See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Micro Family
Page 3 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 75W (e.g. S24C3V3C75BL, V24C3V3C75BL)
Parameter
Min
84.6
80.0
4.14
Efficiency
S24C3V3C75BL (enhanced efficiency)
V24C3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Typ
86.2
81.6
140
4.3
4
±0.02
26.1
26.1
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
175
4.46
6
±0.4
22.72
30.7
30.7
mV
Volts
Watts
%
Amps
Amps
Amps
3.3V
OUT
, 50W (e.g. S24C3V3C50BL, V24C3V3C50BL)
Parameter
Efficiency
S24C3V3C50BL (enhanced efficiency)
V24C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.6
75.0
4.14
Typ
84.0
79.2
240
4.3
1.6
±0.02
17.5
17.5
Max
Unit
%
300
4.46
3
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 125W (e.g. S24C5C125BL, V24C5C125BL)
Parameter
Efficiency
S24C5C125BL (enhanced efficiency)
V24C5C125BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
83.0
6.0
Typ
86.5
84.5
150
6.25
4.3
±0.02
28.8
28.8
Max
Unit
%
188
6.5
5.3
±0.2
25.0
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p Nominal input full load 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250mV
0.0
25.5
17.5
5V
OUT
, 100W (e.g. S24C5C100BL, V24C5C100BL)
Parameter
Efficiency
S24C5C100BL (enhanced efficiency)
V24C5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.9
84.0
6.03
Typ
87.4
85.7
100
6.25
3.2
±0.02
23
23
Max
Unit
%
125
6.47
4.8
±0.2
20
27
27
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
2
24V Micro Family
Page 4 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 50W (e.g. S24C5C50BL, V24C5C50BL)
Parameter
Efficiency
S24C5C50BL (enhanced efficiency)
V24C5C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.5
83.0
6.03
Typ
87.8
84.5
80
6.25
1.3
±0.02
11.5
11.5
Max
Unit
%
100
6.47
2.1
±0.2
10
13.5
13.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
2
8V
OUT
, 100W (e.g. S24C8C100BL, V24C8C100BL)
Parameter
Efficiency
S24C8C100BL (enhanced efficiency)
V24C8C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
85.0
9.36
Typ
89.0
86.4
145
9.7
3
±0.02
14.4
14.4
Max
Unit
%
182
10.1
3.4
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 150W (e.g. S24C12C150BL, V24C12C150BL)
Parameter
Efficiency
S24C12C150BL (enhanced efficiency)
V24C12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.0
87.5
13.8
Typ
89.5
88.8
170
14.3
3.7
±0.02
14.4
14.4
Max
Unit
%
212
14.8
4.5
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p Nominal input full load 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.8
8.8
12V
OUT
, 100W (e.g. S24C12C100BL, V24C12C100BL)
Parameter
Efficiency
S24C12C100BL (enhanced efficiency)
V24C12C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.7
87.0
13.7
Typ
90.2
88.4
209
14.3
4.4
±0.02
9.59
9.59
Max
Unit
%
262
14.9
6.1
±0.2
8.33
10.9
10.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Provide original ECU boards for various protocols (communication lines have been connected), CAN single-line CAN volvocan kwp vpw pwm iso and other protocol ECUs, WeChat: superanonymous...
For this four-tube synchronous boost topology, under what input voltage conditions is the input current the largest? How should I consider selecting components? Can someone please give me some advice?...
[i=s]This post was last edited by btty038 on 2020-6-25 08:21[/i]Power related conceptsNoise-related conceptsAgain, if you don't have time to read this in school, it's your best shortcut to RF. It's qu...
First of all, I would like to thank the forum platform for providing us with such good resources. I haven't participated in forum activities for a long time. This time I happened to be making a small ...
Sensor nodes are required to work for a long time. Frequent replacement of batteries is time-consuming, laborious, and impractical in many situations. They cannot be charged as frequently as portable ...
As an electronics beginner, using a multimeter correctly is the most basic skill. With the development of technology, more and more electronics practitioners are using digital multimeters. This art...[Details]
The three commonly used isolation technologies are photoelectric isolation, electromagnetic isolation and capacitive isolation. The three usually cannot achieve the best in terms of power consumpti...[Details]
With the strong support of SDIC Haichuang Center, Shenzhen Jiangzhi Robotics Co., Ltd. formally established Jiangzhi (Guangzhou) Intelligent Equipment Technology Co., Ltd. with robot hardware publi...[Details]
The three-phase synchronous generator is driven by the prime mover to drive the DC-excited synchronous generator rotor, which rotates at a speed of n (rpm). According to the principle of electro...[Details]
As a long-established Tier 1 giant,
Bosch
's performance remains stable.
Recently, Automotive News released the 2024 Global
Top 100
Auto Parts
Suppliers List. Bosch still ...[Details]
Now, as sales of electric vehicles surge, so does demand for the metal. According to foreign media reports, researchers from Hanyang University in South Korea and the Pacific Northwest National Labor...[Details]
High-performance microprocessors require low-voltage, high-current power supply systems with fast transient response. Therefore, interleaved multiphase synchronous buck converters are widely used as...[Details]
Recently, Guo Bing, a distinguished associate professor at Zhejiang Sci-Tech University, sued Hangzhou Wildlife World in court for refusing to use the facial recognition system to upgrade his annual ...[Details]
Summary: Current shunting in an isolated 0-20mA current loop with a precision resistor analog front end can quickly protect a fuse or automatic current-limiting switch. The circuit shown, unlike th...[Details]
Radiated emissions are the measurement of radiated electromagnetic fields, while conducted emissions are the measurement of conducted electromagnetic interference currents emitted by the product, d...[Details]
On the morning of September 29, it was reported that many of Apple's suppliers in China were affected by the power cuts. According to incomplete statistics, these include the Suzhou plant of printed ...[Details]
Multi-ring network
The availability of PROFINET IO networks in star topology can be increased by using multiple rings.
In a multi-ring configuration, multiple PROFINET lines (star t...[Details]
According to DIGITIMES, Jason Wang, co-general manager of UMC, said that the 28nm process market segment may experience oversupply after 2023. "Based on the announced capacity expansion plans, we d...[Details]
1. The liquid measured by the turbine flowmeter is usually some low-viscosity, low-corrosive liquid. Although there are turbine flowmeters for measuring various media, the measurement of high-temperat...[Details]
Compact PCI (cPCI) power supplies have been widely recognized for their applications in the computer, industrial and telecommunications fields. To optimize system applications, a cPCI power supply use...[Details]