Features
Unregulated
Converters
Description
●
●
●
●
●
●
UL/CSA and EN Safety certified
EN-60601 for Medical Applications
Isolation 6.4kVDC
Optional Continuous Short Circuit Protected
/X2 Option for >9mm Input/Output Clearance
Suitable for IGBT Applications
ECONOLINE
DC/DC-Converter
with 3 year Warranty
The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA-60950 as well as
EN60950 and EN60601. This makes them ideal for medical and safety applications where
approved isolation is required.
Selection Guide
Part
Number
SIP 7
RxxP3.3S*
RxxP05S*
RxxP09S*
RxxP12S*
RxxP15S*
RxxP3.3D*
RxxP05D*
RxxP09D*
RxxP12D*
RxxP15D*
RxxP1509D*
R05P1509D*
Input
Voltage
(VDC)
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
12, 24
5
Output
Voltage
(VDC)
3.3
5
9
12
15
±3.3
±5
±9
±12
±15
+15/-9
+15/-9
Output
Current
(mA)
303
200
111
84
66
±151
±100
±55
±41
±33
+33/-56
±42
Efficiency
Std
(%)
70
70-75
70-75
70-75
75-80
70
70-75
70-75
70-75
75-80
70-80
70-80
Max
Capacitive
Load
(1)
2200µF
1000µF
1000µF
470µF
470µF
±1000µF
±470µF
±470µF
±220µF
±220µF
±220µF
+68µF/-220µF
1 Watt
SIP 7 Single
&
Dual Output
2011/65EU
6/6
RoHS
E-358085
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
R05P05S/P, R05P05D/P
* add Suffix “/X2” for single output with alternative pinout, e.g.
R05P05S/X2, R05P05S/P/X2
EN-60950-1 Certified
IEC/EN-60601-1 Certified*
CSA/UL-60950-1 Certified*
* +15/-9 Version excluded
RxxPxx
±10%
±5%
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz BW)
Operating Frequency
RxxP1509D
Efficiency at Full Load
Minimum Load = 0%
Isolation Voltages
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection, without derating)
Storage Temperature Range
Relative Humidity
(tested for 1 second)
(rated for 1 minute**)
3.3, 5V output types
other output types, RxxP1509D
1.2%/1% of Vin typ.
15% max.
10% max.
200mVp-p max.
20kHz min. / 50kHz typ. / 85kHz max.
20kHz min. / 60kHz typ.
65% min. / 75% typ.
Specifications valid for 10% minimum load only
Derating-Graph
(Ambient Temperature)
100
80
Output Power (%)
6400VDC
3200VAC / 60Hz
4pF min. / 10pF max.
15 GΩ min.
1 Second
Continuous
-40°C to +90°C (see Graph)
-55°C to +125°C
95% RH
continued on next page
60
40
20
0
Safe Operating Area
90 100
95
Operating Temperature °C
-40
0
50
150
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please refer
to our Application Notes.
Refer to Application Notes
www.recom-power.com
REV: 2/2015
E-69
ECONOLINE
DC/DC-Converter
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up))
Package Weight
Packing Quantity
MTBF (+25°C)
Detailed Information see
using MIL-HDBK 217F
Application Notes chapter "MTBF"
(+85°C)
using MIL-HDBK 217F
Certifications
UL/cUL General Safety
Report: E358085-A8
EN General Safety
Report: SPCLVD1305069
EN Medical Safety
Report: SPCMDD1205098-4
Notes
RxxPxxS_D
Series
4.3g
25 pcs per Tube
2974 x 10
3
hours
728 x 10
3
hours
UL 60950-1 2nd Ed.
EN60950-1:2006 + A12: 2011
IEC/EN60601-1:2006, 3rd Edition
}
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Tolerance Envelope
+10%
+5%
V Nom.
Typical L
o
ad Line
+5%
1.5%
5%
Output Voltage
10%
50%
100%
Output Load Current (%)
RxxPxx
Typical Characteristics
Efficiency / Load
100
Deviation / Load
25.000
R05P09S
Efficiency %
RxxP05S
RxxP09S
Deviation from Nominal (%)
80
60
40
20
0
R05P05S
20.000
15.000
10.000
5.000
0.000
-5.000
-10.000
R12P05D
R05P05S
R05P09S
R12P05S
R12P09S
R12P05S
0% 20%
40%
60%
Total Output current (%)
80%
100%
0%
20%
40%
60%
80%
100%
Total Output current (%)
Efficiency / Load
100
Deviation / Load
25.000
R05P09D
Deviation from Nominal (%)
Efficiency %
RxxP05D
RxxP09D
80
60
40
20
0
R05P05D
20.000
15.000
10.000
5.000
0.000
-5.000
-10.000
R12P09D
R05P05D
R05P09D
R12P09D
R12P05D
R12P05D
0% 20%
40%
60%
Total Output current (%)
80%
100%
0%
20%
40%
60%
80%
100%
Total Output current (%)
E-70
REV: 2/2015
www.recom-power.com
ECONOLINE
DC/DC-Converter
Application
RxxPxxS_D
Series
IGBT Application
Circuit
Control Signal
IGBT
Driver
Rg
IGBT
+Vout
1
7
C2 +
-Vin
C1 +
Isolated
DC/DC
Converter
2
6
C3 +
5
-Vout
Package Style and Pinning (mm)
7 PIN SIP Package
9.8
RECOM
R05P05D
****
Dual Output
RECOM
RxxPxxD
Single Output
RECOM
RxxPxxS
****
12.5
0.5
RxxPxx
4.1
7.62
0.5
2.54
0.25
1 2
5 6 7
1 2
5
7
pin clearance
Recommended Footprint Details
19.5
Bottom View
1.00
ø
+0.15/0
RECOM
RxxP1509D
****
RECOM
RxxPxxS/X2
****
2.4
1.9
15.24
2.54
19.5
/X2 Bottom View
Top View
1 2
5 6 7
1 2
6 7
Pin Connections
Pin #
1
2
5
6
7
Single
+Vin
-Vin
–Vout
No Pin
+Vout
Dual
+Vin
–Vin
–Vout
Com
+Vout
/X2
+Vin
–Vin
No Pin
–Vout
+Vout
2.54
0.25
1.00
ø
+0.15/0
2.4
1.9
10.16
pin clearance
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
2.54
/X2 Top View
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-72
REV: 2/2015
www.recom-power.com