Works over 105% of rating and recovers automatically (ACIN 100V)
4.00V min
Works over 115% of rating (By zener diode clamping)
LED (Green)
R10A-24
INPUT
78typ
OUTPUT
24
0.5
96max
150max
120max
160max
150max
180max
240max
290max
96max
21.6 - 26.4
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA max, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B, VCCI-B
26
X
68
X
68mm (W
X
H
X
D) /150g max (without cover)
Convection
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with case cover.
R-2
R10A
External view
R
22
(10)
max
M3
Cover
LED
Voltage Adjust
Safety Cover
(61)
9.5
Name Plate
Name Plate
+
-
FG
AC(L)
AC(N)
CN2
+
-
FG
AC( L)
AC(N)
(13)
2-M3
Mounting Hole
7.5
68
50
t
0.5
º3.5
63.5
Name Plate 2-M3
Mounting Hole
14
22.5
26
14
max
(13.5)
3.5
I/O Connector
CN1
CN2
B3P5-VH
B4P-VH
Mating Connector
VHR-5N
VHR-4N
(21)
(Mfr : J.S.T.)
Terminal
Chain: SVH-21-P1.1
Loose: BVH-21-P1.1
(Mfr : J.S.T.)
Connector type
¶Weight
: 150g or less
(without cover)
¶Cover
is optional
¶Tolerance
:
t1
¶Dimensions
in mm.
Barrier strip type
26
t
0.2
68
36
Mounting torque: 0.6N • m(6.3kgf • cm)max
Performance data
¡
STATIC CHARACTERISTICS (R10A-5)
5.20
¡
RISE TIME & FALL TIME (R10A-5)
Output Voltage
V
5.00
OUTPUT VOLTAGE
4.80
Io=100%
40
4.40
20
4.20
Ripple
RIPPLE
4.60
30
m
V
p-p
DC Output
10
AC Input
ACIN 100V Io=100%
0
50
60
70
80
90
100
110
120
130
INPUT VOLTAGE
V
60Hz
20ms/DIV
¡
OVERCURRENT CHARACTERISTICS (R10A-5)
6.0
¡
DERATING CURVE
100
37
CN1
80
2
1
V
OUTPUT VOLTAGE
5.0
V
OUTPUT VOLTAGE
60
4.0
40
1Convection
2
Forced Air (0.5m
3
/min)
3.0
20
2.0
1.0
0
-10
0
10
20
30
40[30] 50[40] 60[50] 70[60]
0
Please see Electric Characteristics for shaded Ripple,
Ripple Noise.
1.0
2.0
OUTPUT CURRENT
A
AMBIENT TEMPERATURE
ª
Inside of
means with cover
R-3
AC-DC Power Supplies Enclosed type
Ordering information
R
R
R15A
R
1
15A
2
3
-5
4
-O
1Series
name
2Output
wattage
3Output
voltage
4Optional
*2
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
R15A-3
9
3V 3.0A
R15A-5
15
5V 3A
R15A-9
15.3
9V 1.7A
R15A-12
15.6
12V 1.3A
R15A-15
15
15V 1.0A
R15A-18
15.3
18V 0.85A
R15A-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 100V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG, COVER
OUTPUT-FG, COVER
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
R15A-3
R15A-5
R15A-9
R15A-12
AC85 - 132 1
f
or DC110 - 170
0.37typ (Io=100%)
47 - 440 or DC
68typ
72typ
73typ
75typ
20typ (Io=100%) (At cold start)
0.5max (According to UL, CSA and DEN-AN)
3
5
9
12
3.0
3.0
1.7
1.3
20max
20max
36max
48max
40max
40max
100max
100max
80max
80max
120max
120max
140max
140max
160max
160max
120max
120max
150max
150max
160max
160max
180max
180max
50max
50max
90max
120max
60max
60max
120max
150max
20max
20max
36max
48max
100max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%, 0 to +50
C
) 20typ (ACIN 100V,
R15A-15
R15A-18
R15A-24
INPUT
75typ
76typ
78typ
OUTPUT
15
1.0
60max
120max
120max
160max
150max
180max
150max
180max
60max
18
0.85
72max
120max
120max
160max
150max
180max
180max
200max
72max
24
0.7
96max
150max
120max
160max
150max
180max
240max
290max
96max
PROTECTION
CIRCUIT AND
OTHERS
Io=100%, 0 to +50
C
)
2.85 - 3.6
4.5 - 5.5
8.1 - 9.9
10.8 - 13.2
13.5 - 16.5
16.2 - 19.8
Works over 105% of rating and recovers automatically (ACIN 100V)
4.00V min
Works over 115% of rating (By zener diode clamping)
LED (Green)
21.6 - 26.4
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA max, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B, VCCI-B
30
X
69
X
84mm (W
X
H
X
D) / 200g max (without cover)
Convection
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with case cover.
R-4
R15A
External view
R
22
(10)
max
M3 Cover
Name Plate
LED
Voltage Adjust
Name Plate
(63)
(61)
7.5 9.5
+
-
FG
AC(L)
AC(N)
CN2
(13.5)
I/O Connector
CN1
CN2
B3P5-VH
B4P-VH
Mating Housing
Safety Cover
(13.5)
55
t
0.5
18.5
(23.5)
VHR-5N
VHR-4N
(Mfr : J.S.T.)
Terminal
Chain: SVH-21-P1.1
Loose: BVH-21-P1.1
(Mfr : J.S.T.)
Connector type
¶Weight
: 200g or less
(without cover)
¶Cover
is optional
¶Tolerance
:
t1
¶Dimensions
in mm.
Barrier strip type
5 1.75
14
max
74
t
0.5
84
5
Mounting torque: 0.6N • m(6.3kgf • cm)max
Performance data
¡
STATIC CHARACTERISTICS (R15A-5)
5.20
¡
RISE TIME & FALL TIME (R15A-5)
Output Voltage
V
5.00
OUTPUT VOLTAGE
4.80
Io=100%
40
4.40
20
4.20
Ripple
RIPPLE
4.60
30
m
V
p-p
DC Output
10
AC Input
ACIN 100V Io=100%
0
50
60
70
80
90
100
110
120
130
INPUT VOLTAGE
V
60Hz
¡
OVERCURRENT CHARACTERISTICS (R15A-5)
6.0
¡
INRUSH CURRENT (R15A-5)
10A/DIV
V
5.0
OUTPUT VOLTAGE
4.0
Frequency
60Hz
Load
100%
Input voltage AC100V
3.0
2.0
1.0
0
1.0
2.0
3.0
4.0
OUTPUT CURRENT
A
16
25
30
34
3.5
3.5
76
3
2-M3
Name Plate
Mounting Hole
20ms/DIV
10ms/DIV
36.5
CN1
FG
AC(L)
AC(N)
69
+
-
2-M3
Mounting Hole
R-5
AC-DC Power Supplies Enclosed type
Ordering information
R
R
R25A
R
1
25A
2
3
-5
4
-O
1Series
name
2Output
wattage
3Output
voltage
4Optional
*2
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
R25A-3
15
3V 5.0A
R25A-5
25
5V 5A
R25A-9
25.2
9V 2.8A
R25A-12
25.2
12V 2.1A
R25A-15
25.5
15V 1.7A
R25A-18
25.2
18V 1.4A
R25A-24
26.4
24V 1.1A
SPECIFICATIONS
MODEL
VOLTAGE[V]
ACIN 100V
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 100V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
RIPPLE NOISE[mVp-p]
-10 - 0
C
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
1
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG, COVER
OUTPUT-FG, COVER
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
R25A-3
R25A-5
R25A-9
R25A-12
AC85 - 132 1
f
or DC110 - 170
0.58typ (Io=100%)
47 - 440 or DC
69typ
73typ
75typ
76typ
20typ (Io=100%) (At cold start)
0.5max (According to UL, CSA and DEN-AN)
3
5
9
12
5.0
5.0
2.8
2.1
20max
20max
36max
48max
40max
40max
100max
100max
80max
80max
120max
120max
140max
140max
160max
160max
120max
120max
150max
150max
160max
160max
180max
180max
50max
50max
90max
120max
60max
60max
120max
150max
20max
20max
36max
48max
200max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%, 0 to +50
C
) 20typ (ACIN 100V,
R25A-15
R25A-18
R25A-24
INPUT
76typ
77typ
79typ
OUTPUT
15
1.7
60max
120max
120max
160max
150max
180max
150max
180max
60max
18
1.4
72max
120max
120max
160max
150max
180max
180max
200max
72max
24
1.1
96max
150max
120max
160max
150max
180max
240max
290max
96max
PROTECTION
CIRCUIT AND
OTHERS
Io=100%, 0 to +50
C
)
2.85 - 3.6
4.5 - 5.5
8.1 - 9.9
10.8 - 13.2
13.5 - 16.5
16.2 - 19.8
Works over 105% of rating and recovers automatically (ACIN 100V)
4.00 - 5.25V Works at 115 - 140% of rating
LED (Green)
21.6 - 26.4
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*
*
*
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA max, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA max, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL Complies with DEN-AN
Complies with FCC-B, VCCI-B
31
X
69
X
104mm (W
X
H
X
D) / 250g max (without cover)
Convection
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with case cover.
Comprehensive understanding of DFT technology : https://training.eeworld.com.cn/course/5756Comprehensive understanding of DFT technology: How to test a chip...
[i=s]This post was last edited by rain96 on 2019-10-22 14:53[/i]Company Name: Dongguan Liesheng Electronic Technology Co., Ltd. (mainly engaged in Bluetooth headsets, TWS headsets, Bluetooth speakers,...
Figure 1 below compares narrowband and ultra-wideband technologies. UWB pulses (center and right) are only 2 nanoseconds (ns) wide, making them less susceptible to interference from reflected signals ...
I use XKT-335/XKT-412 chip as the emitter circuit and XKT-3169 as the receiver circuit. After running for a short time, the receiver circuit chip gets hot. What is the reason? My instructor said it is...
I post this with the attitude of "not returning the favor". Recently, my company asked me to design a controller that can resist strong interference. Although I have some experience, I still dare not ...
[backcolor=white][color=#000000]When the single-chip microcomputer control circuit detects that a CPU card has been inserted, the processing flow is as follows: [/color][/backcolor] [backcolor=white][...