www.hamlin.com
55100 Mini Flange Mount Hall Effect Sensor Features and Benefits
Features
•
Magnetically operated position sensor
•
Digital, latching or programmable
analogue types available
•
Medium, high or programmable
senisitivities
•
3 wire (voltage output) or 2 wire
(current output) versions
•
Vibration 50g max. @ 50-2,000Hz
•
Shock 150g max. @ 11ms
1
/
2
Sine
•
EMC to DIN 40839 (Consult Hamlin)
•
Reverse/Over Voltage Protection
•
Built in temperature compensation
Benefits
High switching speed up to 10kHz
Long life; up to 20 billion operations
Unaffected by harsh environments
Operates in static or dynamic magnetic
field
•
Customer selection of cable length and
connector type
•
•
•
•
Applications
•
•
•
•
•
•
Position and limit sensing
RPM measurement
Flow metering
Commutation of brushless dc motors
Angle sensing
Magnetic encoders
DIMENSIONS (in) mm
BLOCK DIAGRAMS
Notes
1) Add capacitor Cn as
shown, close to the
sensor, for transient
suppression if required
2) Add resistor Rpu as
shown for sinking output
CUSTOMER OPTIONS - Switching Specifications
SPECIFICATIONS
Hall Type
Absolute Ratings
Operate
Overvoltage Protection
Vdc
Vdc
Vdc-max
Vdc
Vdc-max
mA-max
Low
High
Operating
Storage
mA
mA
kHz-max
O
O
Digital Switch or Digital Latch
3 Wire
(Voltage output)
-15 to +28
+3.8 to +24
32
sinking output
0.4 @
20mA
10
1.6 - 5.2
1.6 - 5.2
10
-40 to +100
-65 to +105
2 Wire
(Current Output)
-15 to +28
+3.75 to +24
32
N/A
N/A
N/A
5-6.9
12-17
10
-40 to +100
-65 to +105
A - Analogue
(Programmable Only) (Note 2)
8.5
4.5-5.5
19.5
4.65
0.35
-1.0 to +1.0
2 - 10
2 - 10
2
-40 to +100
-65 to +105
Supply Voltage
(Note 1)
Output High Voltage
Output Low Voltage
Output Current (continuously on)
Current Consumption over
Temperature Range
Switching Speed
Temperature
C
C
Note 1 - As long as Tj (Junction Temperature) max. is not exceeded
Note 2 - Preprogrammed by Hamlin or Customer pending agreement
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 1
HALL OPTIONS
ACTIVATE DISTANCES ARE APPROXIMATE
USING
N
E
F
E
B
MAGNET
TABLE 2
N
Sensitivity
Gauss (Typ.)
120
57
40
130
59
86
Programmable
S
d
Cable Length:-
(Cable Type 24 AWG 7/32 PVC
105
o
C UL1430/UL1569)
TABLE 3
Termination Options:-
SELECT
OPTION
DESCRIPTION
(2
WIRE VERSION
ILLUSTRATED
)
(.827L
X
HAMLIN P
/
N
.276W
X
.185H) 21
5812334000
X
7
X
4.7
Standard Lengths
Activate - d
(in) mm
(.531) 13.5
(.728) 18.5
(.827) 21.0
(.492) 12.5
(.709) 18.0
(.394) 10.0
Consult Hamlin
SELECT
OPTION
CABLE
LENGTH
A
B
C
D
E
Tinned leads
Crimped terminals
6.35mm fastons
AMP MTE 2.54mm pitch
JST XHP 2.5mm pitch
Select
Hall Option
2M
2H
2L
3M
3H
3L
AP
Hall
Type
2 Wire Switch
2 Wire Switch
2 Wire Latch
3 Wire Switch
3 Wire Switch
3 Wire Latch
Analogue
(in)
01
02
03
04
05
mm
(3.94) 100
(11.81) 300
(19.69) 500
(29.53) 750
(39.37) 1000
ORDERING INFORMATION
55100
Series 55100
Hall option
Cable Length
Termination
Table 1
Table 2
Table 3
XX
XX
X
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Tel:
Tel:
Tel:
Tel:
+1 920 648 3000
•
Fax: +1 920 648 3001
•
Email: sales.us@hamlin.com
+44 (0)1379 649700
•
Fax: +44 (0)1379 649702
•
Email: sales.uk@hamlin.com
+49 (0) 6142 923920
•
Fax: +49 (0) 6142 923921
•
Email: sales.de@hamlin.com
+33 (0) 1 4687 0202
•
Fax: +33 (0) 1 4686 6786
•
Email: sales.fr@hamlin.com
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS
BEING ACCURATE FOR ANY PARTICULAR PURPOSE. Product performance
may be affected by the application to which the product is put. Upon request,
HAMLIN will assist purchasers by providing information specific to any
particular application. HAMLIN disclaims any and all liability whatsoever for any
purchaser’s reliance upon the information contained on this data sheet without
further consultation with authorised representatives of HAMLIN.
Issue No:
AE
Date:
05/02/09
DCR
B6092