NLP40 Series
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
•
•
•
•
•
•
•
•
Single, dual and triple output
40-50 W AC/DC Universal Input Switch Mode Power Supplies
1
4.25 x 2.5 x 1.15 inch package (1U applications)
Smallest industry package
Overvoltage and short circuit protection
40 W with free air convection
EN55022, EN55011 conducted emission level B
EN61000-4-2, -3, -4, -5, -6 immunity compliant
UL, VDE and CSA safety approvals
Available RoHS compliant
The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This product is
the smallest standard 40 W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40 W of output power with free air convection
cooling which can be boosted to 50 W with 20 CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval and
the CE mark, meets conducted noise EN55022 level B and has immunity compliance to
EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals, LCD
projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of
the NLP40 series with industry standard output configurations provides a solution for most
low power applications including many industrial applications.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Total regulation
(Line and load)
Rise time
Transient response
Temperature coefficient
Overvoltage protection
Short circuit protection
Minimum output current
INPUT SPECIFICATIONS
Input voltage range
(See Note 9)
Input frequency range
Input surge current
Safety ground
leakage current
Input current
Input fuse
120 Vac, cold start
230 Vac, cold start
120 Vac, 60 Hz
230 Vac, 50 Hz
120 Vac
230 Vac
UL/IEC127
(10)
GENERAL SPECIFICATIONS
±2.0%
±5.0%
1.0 s, max.
Hold-up time
Efficiency
Isolation voltage
Switching frequency
Approvals and
standards (See Note 8)
Weight
MTBF
MIL-HDBK-217F
Input/output
Input/chassis
Fixed
120 Vac
230 Vac
12 ms @ 40 W
20 ms @ 40 W
75% typical
3000 Vac
1500 Vac
65 kHz, ±5 kHz
EN60950, IEC950, UL1950
VDE0805, CSA C22.2 No. 950
200 g (7.06 oz)
150,000 hours min.
Main output
Auxiliary outputs
At turn-on
Main output
5.0% max. dev.,
25% step at 0.1 A/µs 1 ms rec. to 1.0%
±0.02%/°C
Main outputs
Cyclic operation
Single
Multiple
135%, ±15%
Continuous
0A
(See Note 5)
ENVIRONMENTAL SPECIFICATIONS
Universal input
90-264 Vac
120-370 Vdc
47-440 Hz
15 A max.
30 A max.
0.2 mA
0.4 mA
1.4 A rms
0.7 A rms
250 Vac H 3.15 A
Thermal performance
(See Notes 6, 7, 9)
Operating ambient,
0 °C to +70 °C
(see derating curve)
Non-operating
-40 °C to +70 °C
50 °C to 70 °C ambient,
Derate to
convection cooled
50% load
0 °C to 50 °C, ambient,
40 W
convection cooled
0 °C to 50 °C ambient,
50 W
20 CFM forced air
Peak (0 °C to +50 °C, 60 s) (See Note 2)
Non-condensing
Operating
Non-operating
5-500 Hz
per MIL-STD-810E
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4 G rms peak
516.4 Part IV
Relative humidity
Altitude
Vibration (See Note 4)
Shock
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 3
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
level B
level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
File Name: nlp40.pdf Rev (03): 08 Nov 2005
NLP40 Series
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
OUTPUT
VOLTAGE
+3.3 V (I
A
)
+12 V (I
B
)
–12 V (I
C
)
+5 V (I
A
)
+12 V (I
B
)
–12 V (I
C
)
+5 V (I
A
)
+15 V (I
B
)
–15 V (I
C
)
+12 V (I
A
)
-12 V (I
B
)
+5 V (I
A
)
+12 V (I
B
)
3.3 V (I
A
)
5V
12 V
15 V
24 V
48 V
Notes
1
Single, dual and triple output
40-50 W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
RIPPLE
MAX
4A
2A
0.2 A
4A
2A
0.2 A
4A
1.6 A
0.2 A
1.8 A
1.8 A
4A
2A
8A
8A
3.3 A
2.6 A
1.6 A
0.8 A
(1)
(3)
TOTAL
REGULATION
MODEL NUMBER
NLP40-76T366J
(11,12)
PEAK
5A
3A
1A
5A
3A
1A
5A
2A
1A
(2)
FAN
(1)
4.5 A
3A
0.5 A
4.5 A
3A
0.5 A
4.5 A
2A
0.5 A
2.1 A
2.1 A
4.5 A
3A
9A
9A
4A
3.3 A
2A
1A
50 mV
120 mV
120 mV
50 mV
120 mV
120 mV
50 mV
150 mV
150 mV
120 mV
120 mV
50 mV
120 mV
50 mV
50 mV
120 mV
150 mV
240 mV
300 mV
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±5.0%
±2.0%
±5.0%
±2.0%
±5.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
(5)
NLP40-7608J
(5)
NLP40-7610J
(5)
2.2 A
2.2 A
5A
3A
10 A
10 A
4.5 A
3.6 A
2.5 A
1.1 A
NLP40-7627J
(5)
NLP40-7629J
(5)
NLP40-76S3J
NLP40-7605J
NLP40-7612J
NLP40-7615J
NLP40-7624J
NLP40-7617J
Maximum output power is 40 W for natural convection cooling. With
20 CFM fan cooling, the maximum output power is 50 W.
2
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total reg. limits.
3
Figure is peak-to-peak. Output noise measurements are made across a
50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF
capacitor.
4
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
5
For multiple output units (except -7627J, 76T366J) to maintain stated
regulation then:
0.25 ≤ I
A
/ I
B
≤ 5, for I
B
> 0.3 A
0.50 ≤ I
A
/ I
B
≤ 5, for I
B
< 0.3 A
For maximum output current I(C) on triple output models, i.e. for
I
C
= IMax., I
A
min. ≥ 0.5 A and I
A
≥ I
B
.
For NLP40-7627J only, to maintain stated regulation then:
0.5 ≤ I
A
/ I
B
≤ 2.
For NLP40-76T366J only, to maintain stated regulation then:
0.25 ≤ I
A
/ I
B
≤ 4.
6
For optimum reliability, no part of the heatsink should exceed 120
°
C, and
no semiconductor case temperature should exceed 130
°
C.
7
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
8
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9
When the input voltage is <90 Vac the operating range is 0
°
C to +40
°
C.
10
For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis. It is recommended that this
ground choke be placed as close as possible to the systems ac inlet to
eliminate noise pick-up in the system.
11
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DERATING CURVE
Output Power (Watts)
50W
20 CFM FORCED AIR COOLING
40W
NATURAL
CONVECTION
COOLING
25W
20W
0°C
10°C
20°C
30°C
40°C
50°C
60°C
70°C
File Name: nlp40.pdf Rev (03): 08 Nov 2005
NLP40 Series
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
Single, dual and triple output
40-50 W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
4.25
(107.95)
4.00
(101.60)
J1
N
L
2.50
(63.50)
P1
T1
C5
2.25
(57.15)
F1
1
0.125
(3.175)
J2
ALL DIMENSIONS IN INCHES (mm)
MAXIMUM COMPONENT
HEIGHT 1.15 (29.21)
TOLERANCE: .xxx
±
0.005"
.xx
±
0.02"
Mounting
Hole Diameter
0.138 (3.50) Typical
Input and output connectors
AC (J1) connector type
Molex 26-60-4030 type.
DC (J2) connector type
Molex 26-60-4060 type.
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Line
No Pin
AC Neutral
P1
Pin 1
Safety Ground
Mating connectors
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminals.
DC (J2) mating connector type
Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals.
Note:
The input and output connectors are the same as
those used on NFS40, NFN40, NAL40 and NAN40.
Pin 2
Pin 3
J2
Pin 1
Pin 2
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File 10401-3336-0093
Licence No. 93662
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
OUTPUT PIN CONNECTIONS
SINGLE
DUAL
TRIPLE
+Vout
+Vout
+Vout
Return
Return
Return
V (B)
V (A)
V (A)
Return
Return
Return
V (B)
V (A)
V (A)
Return
Return
V (C)
Pin 3
Pin 4
Pin 5
Pin 6
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: nlp40.pdf Rev (03): 08 Nov 2005