Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V375C12T150BL2
375C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
V
OUT
P
OUT
2V
50W
3.3V
50W, 75W
5V
50W, 100W
8V
100W
12V
75W, 150W
15V
75W, 150W
24V
75W, 150W
28V
75W, 150W
36V
75W, 150W
48V
75W, 150W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= N/A
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
375V Micro Family
Page 1 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
204.7
429.2
242.5
212.2
446.3
467.5
1.1
Min
250
Typ
375
Max
425
500
247.5
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
+OUT to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
375V Micro Family
Page 2 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
.
375V Micro Family
Page 3 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
2V
OUT
, 50W (e.g. S375C2C50BL, V375C2C50BL)
Parameter
Efficiency
S375C2C50BL (enhanced efficiency)
V375C2C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
78.0
72
2.7
Typ
81.0
73.9
80
2.8
2.5
±0.02
28.8
28.8
Max
Unit
%
100
2.9
3.5
±0.2
25
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
3.3V
OUT
, 75W (e.g. S375C3V3C75BL, V375C3V3C75BL)
Parameter
Efficiency
S375C3V3C75BL (enhanced efficiency)
V375C3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
79.0
4.14
Typ
85.0
80.5
94
4.3
3.9
±0.02
24.6
24.6
Max
Unit
%
118
4.46
5.9
±0.4
22.7
30.6
30.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
3.3V
OUT
, 50W (e.g. S375C3V3C50BL, V375C3V3C50BL)
Parameter
Efficiency
S375C3V3C50BL (enhanced efficiency)
V375C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.0
75.7
4.14
Typ
83.0
77
140
4.3
3.4
±0.02
17.5
17.5
Max
Unit
%
175
4.46
4
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 100W (e.g. S375C5C100BL, V375C5C100BL)
Parameter
Efficiency
S375C5C100BL (enhanced efficiency)
V375C5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.3
80
6.03
Typ
82.3
81.8
120
6.25
3.1
±0.02
23
23
Max
Unit
%
150
6.47
5.5
±0.2
20
26
26
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
14
375V Micro Family
Page 4 of 14
Rev 9.6
06/2017
vicorpower.com
800 927.9474
375V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 50W (e.g. S375C5C50BL, V375C5C50BL)
Parameter
Efficiency
S375C5C50BL (enhanced efficiency)
V375C5C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
79.5
6.03
Typ
85.0
80.9
120
6.25
2.7
±0.02
11.5
11.5
Max
Unit
%
150
6.47
3.4
±0.2
10
13.5
13.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
7
8V
OUT
, 100W (e.g. S375C8C100BL, V375C8C100BL)
Parameter
Efficiency
S375C8C100BL (enhanced efficiency)
V375C8C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
82.5
9.36
Typ
87.0
83.7
180
9.7
3.6
±0.02
14.4
14.4
Max
Unit
%
225
10.1
4.2
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 150W (e.g. S375C12C150BL, V375C12C150BL)
Parameter
Efficiency
S375C12C150BL (enhanced efficiency)
V375C12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
85.0
13.7
Typ
86.0
86.0
220
14.3
5.4
±0.02
14.4
14.4
Max
Unit
%
275
14.9
7.4
±0.2
12.5
16.9
17.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 75W (e.g. S375C12C75BL, V375C12C75BL)
Parameter
Efficiency
S375C12C75BL (enhanced efficiency)
V375C12C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
84.0
13.7
Typ
88.0
85.5
100
14.3
3.5
±0.02
7.19
7.19
Max
Unit
%
125
14.9
4
±0.2
6.25
8.44
8.44
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
[font=微软雅黑, "][size=14px][size=12pt]The wireless charging electric car charges the farad capacitor through a wireless charging device. After it is fully charged, it is powered by [/size][size=12pt]DC-...
1. Radar sensor principle:
Before development, let’s get familiar with the basic principles:Doppler radar:Doppler radar is a type of radar that uses the Doppler effect to detect the position and relat...
[i=s]This post was last edited by qwqwqw2088 on 2019-9-25 08:54[/i]Serial communication is the most basic communication method for electrical engineers, and RS-232 is the simplest one. Many beginners ...
[i=s]This post was last edited by Min丨Dayu on 2019-8-30 12:46[/i]This content is originally created by EEWORLD forum user Min Da. If you want to reprint or use it for commercial purposes, you must obt...
China Energy Storage Network News:
On August 10, the 2016 China Energy Internet Conference and Smart Energy Industry Expo opened grandly in Qinhuangdao Economic and Technological Development ...[Details]
Teledyne e2v Semiconductors and Safran Electronics & Defense have joined forces to develop a System-in-Package roadmap with French government support as part of France’s recovery plan Grenoble, Fra...[Details]
ECU is the control center of the ABS system. Its essence is a micro digital computer. It is generally composed of two microprocessors and other necessary circuits. It is an integral unit that canno...[Details]
Today (9), Cirrus Logic announced that it has reached an agreement to acquire California-based Lion Semiconductor for $335 million in cash. Cirrus Logic mentioned that the acquisition brings unique i...[Details]
From the end of January to the beginning of February 2021, the world's three largest inverter companies successively issued statements, announcing that inverters that perfectly match 210 ultra-high...[Details]
According to the latest report from TrendForce's semiconductor research department, due to the full capacity of upstream wafer foundries such as TSMC and UMC, and the shortage of downstream packaging...[Details]
This design aims to produce a powerful alarm system that can notify the parties in time when an emergency occurs, even if they are not near the scene, and automatically call the alarm. Compared with o...[Details]
"There are more than 100 orthopedic surgery companies in China alone, even more than overseas. Isn't this number a bit too much?" A practitioner raised this question at a recent medical robot event...[Details]
1. Introduction
Most medical ultrasound diagnostic imaging technologies use the ultrasonic pulse echo method, which uses a probe to generate ultrasound waves that enter the human body. The ech...[Details]
At present, the LED fluorescent lighting market is relatively active, and LED driver power supply manufacturers are mainly divided into three categories: the first category is the factory that...[Details]
With the rapid development of computer application technology, mobile storage devices have been widely used. Among them, CF (Compact Flash) card was born in 1994. It is the earliest flash memory card...[Details]
As
LED
lighting becomes more and more popular, LED
driver
power supply
, the life support of LED,
is also attracting more and more attention.
We all know that there is no...[Details]
Since the advent of radar level meter, it has been widely used. Most people already know that the only disadvantage of radar level meter is the false level problem. It is also called interference pr...[Details]
The forward and reverse wiring of a three-phase inverter is a highly technical job, involving many aspects such as electrical principles, wiring methods and safe operation. This article will introd...[Details]