General Purpose
Low Power PCB Relays
Special Load PCB Relay RP3SL
n
n
n
n
SCHRACK
1 pole 16A, 1 form A (NO) contact
For high inrush currents up to 120A
Mono- or bistable
4kV/8mm coil-contact
Typical applications
Lighting control, timers, motor control, building automation.
Z
Approvals
VDE REG.-Nr. C894 (DC versions only), UL E214024
Technical data of approved types on request.
Coil Data
Coil data, monostable coil
Coil voltage range
Operative range, IEC 61810
flux proof version
wash tight version
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.8
006
6
4.5
012
12
9.0
024
24
18.0
048
48
36.0
060
60
45.0
Release
voltage
VDC
0.5
0.6
1.2
2.4
4.8
6.0
5 to 110VDC
2
1
Coil
resistance
Ω±10%
1)
54
68
270
1100
1)
4400
1)
6540
1)
Rated coil
power
mW
500
500
500
500
500
500
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
flux proof version
wash tight version
Limiting making current
max. 4 s, duty factor 10 %
max. 20 ms (incandescent lamp)
Breaking capacity max.
flux proof version
wash tight version
Contact material
Frequency of operation, with/without load
Operate/release time max., monostable
Set/reset time max., bistable
Bounce time max.
monostable
bistable
Contact ratings
Type
Contact
IEC61810
RP3SL
RP7SL
A (NO)
A (NO)
Contact Data
1 form A (NO)
250VAC
400VAC
16A
12A
25A
120A
4000VA
3000VA
AgSnO
960/72000h
-1
14/12ms
30/25ms
5/7ms
5/15ms
Load
16A, 250VAC resistive, 70°C
12A, 250VAC resistive, 70°C
>20x10 operations
>1x10
6
operations
6
Cycles
50x10
3
100x10
3
Coil Data, bistable coil
Coil voltage range
Operative range, IEC 61810
Reset voltage min/max, % of Urtd
Min./Max. energization duration
Coil versions, bistable
Coil
Rated
Set
Reset
code
voltage
voltage voltage
VDC
VDC
VDC
Coil versions, bistable 1 coil
A05
5
3.7
3.6
A12
12
9.0
8.7
A24
24
18.0
16.7
Coil versions, bistable 2 coils
F12
12
9.0
9.0
F24
24
18.0
18.0
2 coils
5 to 24VDC
1
70/110%
75/120%
20ms/1min at < 50%DF
Reset
R1
Ω/W
39/0.5
220/0.5
820/0.5
Coil
Rated coil
resistance power
mW
Ω±10%
1)
21
115
460
105
1)
460
1)
1250
1250
1250
1250
1250
1 coil
Mechanical endurance
monostable
bistable
1) Coil resistance ±15% .
All figures are given for coil without pre-energization, at ambient temperature +23°C, duty
factor 20%. Other coil voltages on request.
01-2013, Rev. 0113
www.te.com
© 2013 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
1
General Purpose
Low Power PCB Relays
Special Load PCB Relay RP3SL
(Continued)
Insulation Data
SCHRACK
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
between contact and coil
Material group of insulation parts
Tracking index of relay base
Circuit scheme for bistable 1 coil
2000V
rms
4000V
rms
≥8/8mm
IIIa
PTI250V
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
flux proof version
-40 to +70°C
wash tight version
-40 to +35°C
Category of environmental protection
IEC 61810
RTII - flux proof, RTIII - wash tight
Vibration resistance (functional), form A contact
20g
Shock resistance (destructive)
100g
Terminal type
PCB-THT
Mounting distance, 12A/16A
0mm/≥3mm
Weight
18g
Resistance to soldering heat THT, IEC 60068-2-20
flux proof version
270°C/10s
wash tight version
260°C/5s
Packaging/unit
monostable and bistable 1coil version tube/20 pcs., box/500 pcs.
bistable 2coil version
tray/25 pcs., box/100 pcs.
PCB layout / terminal assignment
Bottom view on solder pins
Bistable versions:
Indicated contact position during or after coil
energization with reset voltage.
2-coil versions:
Operate A2, A3
Reset A1, A3
b) for 2 coil version only
Dimensions
2
01-2013, Rev. 0113
www.te.com
© 2013 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
General Purpose
Low Power PCB Relays
Special Load PCB Relay RP3SL
(Continued)
Product code structure
Type
RP
Special Load PCB Relay RP 3 SL
Version
3
Flux proof
Contact configuration / contact material
SL
1 form A contact (1 NO), AgSnO
2
Coil
Coil code: please refer to coil versions table
Typical product code
SCHRACK
RP
3
SL
012
7
Wash tight
RP3SL005
1 form A (NO) contact
AgSnO
DC coil
RP3SL012
16A
RP3SL018
flux proof
RP3SL024
RP3SL048
RP3SL060
RP3SLA06
Bistable 1 coil
RP3SLA24
RP3SLF12
Bistable 2 coils
This list represents the most common types and does not show all variants covered by this datasheet.
Other types on request.
Product code
Version
Contact material
Coil version
5VDC
12VDC
18VDC
24VDC
48VDC
60VDC
6VDC
24VDC
12VDC
Coil
Part number
1393230-7
1393230-9
1-1393230-0
1-1393230-1
1-1393230-2
1-1393230-3
1393230-2
1393230-4
1393230-5
01-2013, Rev. 0113
www.te.com
© 2013 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
3