EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-375C03Q-55-1MM1

Description
Mains Power Connector, 3A, 125/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size485KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

HGN-375C03Q-55-1MM1 Overview

Mains Power Connector, 3A, 125/250VAC, Male, Socket

HGN-375C03Q-55-1MM1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid2099200131
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL8.5
Other featuresSTANDARDS: IEC 60320; UL; VDE
body width1.26 inch
subject depth1.917 inch
body length2.56 inch
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings3A, 125/250VAC
Installation typePANEL
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
OptionsGENERAL PURPOSE
GuidelineCE; CUL
Shell materialMETAL
Termination typeQUICK CONNECT
Total number of contacts3
HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81
Design of balanced loop antenna based on MLX71120/21 receiver
This article outlines the design of balanced loop antennas for MELEXIS wireless receiver chips MLX71120 and MLX71121. A detailed design process is provided, including complete calculation steps. All c...
Jacktang Wireless Connectivity
SensorTile.Box Evaluation Kit and My Thoughts
SensorTile.Box Evaluation Kit and My Thoughts# First Look at the SensorTile.Box Evaluation Kit I received the SensorTile.Box Evaluation Kit very quickly. ## External Packaging## Packing List 1. JTAG A...
lvqy ST MEMS Sensor Creative Design Competition
I am a PCB newbie and would like to ask about the relationship between PCB trace width and current carrying capacity.
As the title says. I have searched a lot on the Internet about the calculation relationship between the two. For the case of 1 ounce copper thickness, some say that a line width of 1mm can only carry ...
daisy089412 PCB Design
【MM32 eMiniBoard Review】3. Testing ADC Accuracy and Linearity + A Little Technique That May Have Been Lost
[i=s]This post was last edited by mig29 on 2020-11-22 14:31[/i]This example uses the demo ..\MM32F013x_Samples\LibSamples\ADC\ADC_Polling to measurethe accuracy and linearity of the ADC.1. First, cali...
mig29 Domestic Chip Exchange
Smart Micro MM32F0270 timer DMA mode output PWM
For controlling stepper motors, the most important control parameters are the number and frequency of pulses. The combination of the two can achieve the required motor acceleration and deceleration cu...
火辣西米秀 Domestic Chip Exchange

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号