Part Number

Search

7301L2HAW4BES2

Description
TOGGLE SWITCH, 3PDT, LATCHED, 0.02A, 20VDC, THROUGH HOLE-RIGHT ANGLE, ROHS COMPLAINT
CategoryMechanical and electronic products    switch   
File Size1015KB,14 Pages
ManufacturerC&K Components
Environmental Compliance  
Download Datasheet Parametric View All

7301L2HAW4BES2 Overview

TOGGLE SWITCH, 3PDT, LATCHED, 0.02A, 20VDC, THROUGH HOLE-RIGHT ANGLE, ROHS COMPLAINT

7301L2HAW4BES2 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1886123019
package instructionROHS COMPLAINT
Reach Compliance Codenot_compliant
Country Of OriginVietnam
ECCN codeEAR99
YTEOL8.7
body width12.7 mm
body height16.51 mm
Body length or diameter14.35 mm
Contact (AC) maximum rated R load.02A@20VAC
Maximum contact current (AC)0.02 A
Maximum contact current (DC)0.02 A
Contact (DC) maximum rated R load.02A@20VDC
Maximum contact voltage (AC)20 V
Maximum contact voltage (DC)20 V
Electrical life100000 Cycle(s)
JESD-609 codee4
Installation featuresTHROUGH HOLE-RIGHT ANGLE
Maximum operating temperature85 °C
Minimum operating temperature-30 °C
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED
switch function3PDT
Switch typeTOGGLE SWITCH
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Termination typeSOLDER
7000 Series
Miniature Toggle Switches
Features/Benefits
Multi-pole and multi-position
Wide variety of actuator and
termination options
Typical Applications
Telecommunications
Instrumentation
Medical equipment
Epoxy terminal-seal compatible
with bottom wash cleaning
RoHS complaint models available
Models Available
Specifications
CONTACT RATING: B contact material: 0.4 VA max. @ 20 V AC or
DC max. Q contact material: 5 AMPS @ 120 V AC or 28 V DC;
2 AMPS @ 250 V AC. See page G-16 for additional ratings.
ELECTRICAL LIFE: 7X01 and UX1 models: 100,000 make-and-break
cycles at full load. All other models: 40,000 cycles.
CONTACT RESISTANCE: Below 10 m
typ. initial @ 2-4 V DC,
100 mA, for both silver and gold plated contacts.
INSULATION RESISTANCE: 109
min.
DIELECTRIC STRENGTH: 1000 Vrms min. @ sea level.
OPERATING TEMPERATURE: –30ºC to 85ºC.
SOLDERABILITY: Per MIL-STD-202F method 208D, or EIA RS-186E
method 9 (1 hour steam aging).
For materials see page F-4.
NOTE:
Any models supplied with P, S R, Q, B or G contact material are RoHS compliant
and compatible.
NOTE:
Specifications listed above are for switches with standard options. For information
on specific and custom switches, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages F–4 thru F–16. For additional options not shown in catalog, consult our Customer Service Center.
Switch Function
7101
SP On-None-On
7103
SP On-Off-On
7105
SP Mom.-Off-Mom.
7107
SP On-Off-Mom.
7108
SP On-None-Mom.
7109
SP None-On-Mom.
7201
DP On-None-On
7203
DP On-Off-On
7205
DP Mom.-Off-Mom.
7207
DP On-Off-Mom.
7208
DP On-None-Mom.
7211
DP On-On-On
7213
DP On-On-Mom.
7215
DP Mom.-On-Mom.
7301
3P On-None-On
7303
3P On-Off-On
7305
3P Mom.-Off-Mom.
7308
3P On-None-Mom.
7401
4P On-None-On
7403
4P On-Off-On
7405
4P Mom.-Off-Mom.
7408
4P On-None-Mom.
7411
4P On-On-On
7413
4P On-On-Mom.
7415
4P Mom.-On-Mom.
Note:
UL/CSA models available,
see pages F-4 & F-5.
Actuator
M
.200" high
P3
Flatted, anti-rotation,
.450" high
S
.420" high
T
.687" high, 15/32 bushing
K2
Locking lever, .704" high
K9
Locking lever, .704" high
K12
Locking lever, .732" high
K19
Locking lever, .732" high
L
.840" high
L1
.640" high
L1P
Anti-rotation, .640" high
L2
.550" high
L2P
Anti-rotation, .550" high
L3
Plastic .940” inch
L40
Lever handle without cap
L41
.531" high lever handle with cap
L42
.838" high lever handle with cap
MP
Anti-rotation, .200" high
P1
Flatted, anti-rotation,
.840" high
P4
Flatted, anti-rotation,
.250" high
SP
Anti-rotation, .420" high
T1
.487" high, 15/32 bushing
T1P
Anti-rotation, .487" high,
15/32 bushing
T2P
Flatted, anti-rotation,
.610” high, 15/32 bushing,
TP
Anti-rotation, .687" high,
15/32 bushing
Bushing
D
.280 high, keyway
H
.296 high, flat
Y
.350 high, keyway
NONE
No bushing
choice required
CW
Splashproof
D8
.280" high, flat
D9
.280" high, keyway
H3
.315" high, keyway
H4
8mm high, keyway
Y1
.378" high, keyway
Y3
8.9mm high, keyway
Y4
.378" high, flat
Y9
.350" high, keyway
Contact Material
B
Gold
Seal
P
Gold, matte-tin
E
Epoxy
Q
Silver
I
Epoxy potted
S
Silver, matte-tin
base
G
Gold over silver
R
Gold over silver, matte-tin
Terminations
Right angle, PC thru-hole
A
AV2
Vert. right angle, PC thru-hole
C
PC Thru-hole
V3
.460 high, V-bracket
Z
Solder lug
A2
Right angle, PC thru-hole
A3
Right angle, PC thru-hole
A4
Right angle, PC thru-hole
AW1
Right angle, extended, PC thru-hole
AW4
Right angle, extended, PC thru-hole
V2
.555" high, V-bracket
V4
.630" high, V-bracket
V6
.460" high, V-bracket
V7
.630" high, V-bracket
V8
.953" high, V-bracket
W
V9
1.150" high, V-bracket
V21
.555" high, snap-in V-bracket
W1
V31
.460" high, snap-in V-bracket
W3
V41
.630" high, snap-in V-bracket
W4
W5
V71
.630" high, snap-in V-bracket
Z3
V81
.953" high, snap-in V-bracket
Actuator Color/Finish
NONE
Bright chrome
2
Black
3
Red
S
Satin chrome
KXX Actuator Color/Finish
NONE
Natural aluminum
2
Black anodized aluminum
3
Red anodized aluminum
7
Blue anodized aluminum
Bushing Finish
NONE
Nickel on all
bushings (except D8,
satin chrome)
2
Black
.750" long, wire wrap
.964" long, wire wrap
.425" long, wire wrap
1.062" long, wire wrap
1.305" long, wire wrap
Quick connect
F
Toggle
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
F–3
www.ck-components.com
Practical case of switching power supply EMI rectification
[i=s]This post was last edited by qwqwqw2088 on 2019-8-19 08:33[/i]This is a power supply with a wide input voltage of 120-277V 60HZ, an output of 48V, 273mA, and a Buck topology.Note: In the initial ...
qwqwqw2088 Analogue and Mixed Signal
Principle and application of relay protection in power system
"Principles and Applications of Relay Protection in Power Systems" first introduces the basic concepts of conventional protection and microcomputer protection in power system relay protection, and the...
arui1999 Download Centre
Aren't all charging stations AC-DC, used to charge electric vehicles? Why are there DC charging stations?
Aren't all charging piles AC-DC, and then charge electric vehicles? Why are there DC charging piles? -----------A DC charging pile is a charging pile where the battery pack charges the battery pack of...
QWE4562009 Integrated technical exchanges
Solution to the problem that IAR compiles very slowly and prompts NO Valid when compiling the first file
[size=4]Share this with everyone... [/size] [size=4] [/size] [size=4] When you install IAR For ARM, you may encounter the following situation: everything from entering the registration code to install...
Jacktang Microcontroller MCU
[STM32WB55 Review] BLE_p2pServer Project Extraction & Compilation
CubeWB provides a lot of examples that can be used directly in the software development environment. It supports three IDEs - IAR EWARM, MDK-ARM and SW4STM32. The latter uses the GCC compiler. I don't...
cruelfox RF/Wirelessly
Why does the electromagnetic flow meter have a lining?
As for why electromagnetic flowmeters need linings, we should start with the principle of electromagnetic flowmeters. Electromagnetic flowmeters generally have a set of coils and two electrodes. The f...
cfybhd Sensor

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号