Radial Leaded PTC
0ZRA1006D
RoHS6 Compliant
0ZRA Series
may200#A44
Electrical Characteristics (23
0
C)
Part
Number
Hold
Trip Max Time to Trip Max
Current Current
@ 5
x
I
H
Current
I
H
, A
I
T
, A
Seconds
Rated Typical
Voltage Power
Resistance Tolerance
R
min
R
max
Ohms
R1
max
Ohms
I
max,
A V
max,
V
dc
P
d
, W Ohms
Application
High Current Applications
Product Features
Very High Hold Currents, Low DCR Resistance
Operating (Hold Current) Range
3 A ~ 14A
Maximum Voltage
16V
Temperature Range
-40°C to 85°C
Agency Approval
UL Component (E305051)
A 0ZRA0300
B 0ZRA0400
C 0ZRA0500
D 0ZRA0600
E 0ZRA0700
F 0ZRA0800
G 0ZRA0900
H 0ZRA1000
I 0ZRA1100
J 0ZRA1200
K 0ZRA1400
3
4
5
6
7
8
9
10
11
12
14
5.1
6.8
8.5
10.2
11.9
13.6
15.3
17.0
18.7
20.4
23.8
2.0
3.5
3.6
5.8
8.0
9.0
12.0
12.5
13.5
16.0
20.0
100
100
100
100
100
100
100
100
100
100
100
16
16
16
16
16
16
16
16
16
16
16
2.3
2.4
2.6
2.8
3.0
3.0
3.3
3.3
3.7
4.2
4.6
0.034 0.0530 0.105
0.020 0.0350 0.063
0.014 0.0210 0.044
0.009 0.0160 0.033
0.006 0.0130 0.021
0.005 0.0110 0.018
0.004 0.0085 0.015
0.003 0.0075 0.012
0.003 0.0065 0.010
0.002 0.0055 0.009
0.002 0.0045 0.008
Product Dimensions
A
E
B
D
ø
Lead
Size
C
ø
B
C
øø
D
F
All dimensions
in mm
I
H
I
T
I
max
V
max
P
d
R
min
R
max
R1
max
Hold current-maximum current at which the device will not trip in still air at 23°C.
Trip current-minimum current at which the device will always trip in still air at 23°C.
Maximum fault current device can withstand without damage at rated voltage (Vmax).
Maximum voltage device can withstand without damage at its rated current.
Typical power dissipated from device when in the tripped state in 23°C still air environment.
Minimum device resistance at 23°C.
Maximum device resistance at 23°C.
Maximum device resistance at 23°C, 1 hour after initial device trip.
Part
Number
A
E
F
ø
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
1.00
1.00
Max Max Typical Min Max Typical
Physical specifications
Lead material
0ZRA0300 ~ 0ZRA1100 - Tin plated copper, 20 AWG.
0ZRA1200 ~ 0ZRA1400 - Tin plated copper, 18 AWG.
Soldering characteristics
MIL-STD-202, Method 208E.
Insulating coating
Flame retardant epoxy, meets UL-94-V-0 requirements.
0ZRA0300
0ZRA0400
0ZRA0500
0ZRA0600
0ZRA0700
0ZRA0800
0ZRA0900
0ZRA1000
0ZRA1100
0ZRA1200
0ZRA1400
7.1 11.0
8.9 12.8
10.4 14.3
10.7 17.1
11.2 19.7
12.7 20.9
14.0 21.7
16.5 24.1
17.5 26.0
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.6
3.6
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
17.5 28.0 10.2
27.9 27.9 10.2
PTC Marking
“bel” or “b”, I
H
code and “RA”.
Standard Package
P/N
Bulk
Pcs/Box P/N Code
Reel/Tape
Pcs/Reel
P/N Code
0ZRA0300
0ZRA0400-0600
0ZRA0700-1400
2000
3000
1000
1C
1E
1A
2500
2500
n/a
2D
2D
n/a
S
pecifications subject to change without
notice
Bel Fuse Inc.
206 Van Vorst Street, Jersey City, NJ 07302 • Tel: 201-432-0463 • Fax: 201-432-9542 • E-Mail: belfuse@belfuse.com
Website: www.belfuse.com
Radial Leaded PTC
0ZRA Series
Typical Time -To - Trip at 23
0
C
RoHS6 Compliant
0ZRA1006C
may200#A44
(See Elec. Characteristics Table for P/N - Curve Correlation)
A B C D E F G H I J K
1000
100
Time - To - Trip (S)
10
1
0.1
0.01
0.001
1
10
100
Fault Current (A)
Cautionary Notes
Thermal Derating Curve
200%
150%
100%
50%
0%
-40
-20
0
20
40
60
80
1. Operation beyond the specified maximum ratings or
improper use may result in damage and possible
electrical arcing and/or flame.
2. These Polymer PTC (PPTC) devices are intended for
protection against occasional overcurrent/
overtemperature fault conditions and may not be
suitable for use in applications where repeated and/
or prolonged fault conditions are anticipated.
3. Avoid contact of PTC device with chemical solvent.
Prolonged contact may adversely impact the PTC
performance.
4. These PTC devices may not be suitable for use in
circuits with a large inductance, as the PTC trip can
generate circuit voltage spikes above the PTC
rated voltage.
S
pecifications subject to change without
notice
Percent Of Rated Hold And
Trip Current
Ambient Temperature (
o
C)
Corporate Office
Bel Fuse Inc.
206 Van Vorst Street, Jersey City, NJ 07302
Tel: 201-432-0463
Fax: 201-432-9542
E-Mail: belfuse@belfuse.com
Website: www.belfuse.com
Far East Office
Bel Fuse Ltd.
8F/8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel: 852-2328-5515
Fax: 852-2352-3706
European Office
Bel Stewart GmbH
Industriestrasse 20
61381 Friedrichdorf
Germany
Tel: 49.6172.9552.0
Fax: 49.6172.9552.40