M7100
Pressure Transducer
SPECIFICATIONS
Performance standard on and off highway engine and
vehicle OEMs
Rugged for heavy equipment and outdoor use
Designed specifically for high volume applications
Stainless steel wetted surfaces
Medium to high pressures
CE Approved
UL Certified
Gage
FEATURES
Hermetic Pressure Ports
Integral Electrical Connector
Survives High Vibration
±0.25% Accuracy
Water Resistant 1M Immersion
The M7100 pressure transducer from the Microfused line of MEAS
sets a new price performance standard for demanding engine and
vehicle, and industrial applications. This transducer is suitable for
measurement of liquid or gas pressure, even for difficult media
such as contaminated water, steam and corrosive fluids.
The transducer pressure cavity is machined from a solid piece of
17-4 PH stainless steel. The standard version includes a 1/4 NPT
pipe thread allowing a leak-proof, all metal sealed system. There
are no O-rings or organics exposed to the pressure media and the
durability is excellent. This automotive grade pressure transducer
with stainless steel hermetic pressure ports and integral electrical
connector can boast up to 10,000psi (700bar). The M7100 is UL
certified and exceeds the latest industrial CE requirements
including surge protection and is overvoltage protected in both
positive and reverse polarity.
APPLICATIONS
On and Off Highway Engines and Vehicles
HVAC Refrigeration Controls
Compressors
Hydraulics
Energy and Water Management
SENSOR SOLUTIONS
///M7100
06/2018
Page 1
M7100
Pressure Transducer
STANDARD RANGES
Range (psi)
0 to 150
0 to 200
0 to 300
0 to 500
0 to 01K
0 to 1K5
0 to 03K
0 to 05K
0 to 7K5
0 to 10K
Range (bar)
0 to 010
0 to 014
0 to 020
0 to 035
0 to 070
0 to 100
0 to 200
0 to 350
0 to 500
0 to 700
Gage
PERFORMANCE SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified);
PARAMETERS
Load Resistance
Accuracy (combined linearity, hysteresis & repeatability)
Total Error Band
Compensated Temperature
Operating Temperature
Storage Temperature
Insulation Resistance (500V
DC
)
Short Circuit Protected
Output Noise @ 1kHZ
Long Term Stability
Frequency Response @ -3dB
-0.25
1
-1.0
-20
-40
-50
100
Yes
10
0.25
mV
%Span/Year
kHz
MIN
Steel
10
-0.25
-2.5
-30
1.0
+85
+125
+125
0.25
2.5
120
Copper
TYP
Steel
MAX
Copper
UNITS
KΩ
%Span
%Span
°C
°C
°C
MΩ
4
3
1
2
NOTES
Notes
1.
Best fit straight line.
2.
TEB includes all accuracy errors, thermal errors, span and zero tolerances over the compensated temperature range.
3.
Temperature range for product with standard cable is -20°C to +105°C.
4.
Between sensor body to any pins of connector.
5.
The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
6.
The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
7.
Refer to pressure port Listing notes for installation recommendations.
8.
This product can be configured for custom OEM requirements. Contact Factory for different transfer function. See “Pressure
Transfer
Function’ diagram.
9.
Maximum temperature range for product with standard cable is -20
o
C to 105
o
C.
10. Do not apply torque to connector housing of transducer
11. To ensure proper environmental sealing and electrical connections when using a mating connector, follow
the connector manufacturer’s
installation guidelines.
SENSOR SOLUTIONS
///M7100
06/2018
Page 2
M7100
Pressure Transducer
ENVIRONMENTAL SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS
MIN
Steel
Copper
Humidity (@40°C)
Pressure Overload
Pressure Burst
Pressure Cycle
Media, Pressure Port
Steel
Copper
Steel
Copper
Mechanical Shock
Package Protection
.
Steel
Copper
10M
Fluids compatible with 17-4PH Stainless Steel
Fluids compatible with Brass
20g, 10 ~ 2000Hz
MIL-STD-810C, Method 514.2, Curve L
10g peak, 55~2000Hz MIL-STD-202G, Method 204D, Test Condition C
Half-Sine, Peak: 50g, 11ms
MIL-STD-202, Method 213B, Condition A
Half-Sine, Peak: 50g, 11ms MIL-STD-202G, Method 213B, Condition A
IP67 (IEC60529)
5X
TYP
MAX
Steel
Copper
93
2X
3X
UNITS
%RH
Rated
Rated
Cycles
5
6
NOTES
Mechanical Vibration
AGENCY APPROVALS
RoHS: RoHS 2 (Directive 2011/65/EU)
Industrial Control Equipment CSA 22.2 No. 14-10
UL508 Certified
EMC Performance Criteria: Output Change < ±1.5% FSO
ESD
8kV Contact/15kV Air; Discharge Rate >10s
IEC 61000-4-2
EM Field
100V/m, 1kHz 80% Modulation, 80 ~ 1000MHz
IEC 61000-4-3
Electrical Fast Transient
Level 2, 1kV each line, capacitance coupling
IEC 61000-4-4
Surge
Level 2, 42Ω Impedance, Figure 11 (L-L
500V, L-E 1kV)
IEC 61000-4-5
Conducted RF
Level 2, 3V/130dB, 150kHz ~ 80MHz, 2s Dwell, Clamp Injection
IEC 61000-4-6
Pulse Magnetic Field
Level 3, 100A/m, 10 second pulse interval
IEC 61000-4-9
Emission
Class B, 30dB @ 30-230MHz, 37dB @ 230
–
1000MHz
IEC 55022
SENSOR SOLUTIONS
///M7100
06/2018
Page 3
M7100
Pressure Transducer
PRESSURE PORT INFORMATION
Pressure Port Options
2 = G1/4, BS5380, Male
4 = 7-16-20 UNF, SAE J1926-2, Male, w/ O-Ring
5 = 1/4-18 NPT Male
6 = 1/8-27 NPT Male
E = R1/4-19, Male
F = G1/4-19, BS5380, Female
P = 7/16-20UNF Female w/ Integral Valve Depressor;
1/4 Flare Gasket SAE J513C, Copper
Q = M10 x 1.0, ISO 6149-2, Male
S = M12 x 1.5, ISO 6149-2, Male
G = M14 x 1.5, ISO 6149-2, Male
U = G1/4, DIN 3852-E, Male
Notes: Installation
*T.F.F.T.: Turns From Finger Tight
Transducers can be installed by either spanner or deep socket. Torque values provided are for reference: actual torque depends upon mating
port material, surface finish, lubrication and sealing mechanism. Transducers calibration and/or zero may shift if part is over-torqued during
installation. Check for a zero shift after installing.
Dim A
.43 [11.0]
.36 [9.1]
.56 [14.2]
.38 [9.7]
.56 [14.2]
.64 [16.3]
.64 [16.3]
.37 [9.5]
.43 [11.0]
.43 [11.0]
.47 [12.0]
Tightening Torque (Nm)
30~35
18~20
2~3 T.F.F.T.
2~3 T.F.F.T.
2~3 T.F.F.T.
30~35
15~16
15~16
28~30
30~35
30~35
CONNECTOR INFORMATION
Connector
Packard Metri-Pack 150 Series
Sumitomo HV040 Series
AMP Econoseal-J Mark II 070 Series
Connector, Pin Plating
powerandsignal.com
sumitomokenki.com
te.com
0.003
–
0.005 mm Sn
0.003 mm Sn over
0.0005
–
0.001 mm Cu
0.0004 mm Au over
0.0013 mm Ni
Connector, Mating
Housing P/N: 12065287
Terminals P/N: 12103881
Housing P/N: 6189-6907
Terminals P/N: 8100-3067/8
Housing P/N: 174357
Terminals P/N: 171630
SENSOR SOLUTIONS
///M7100
06/2018
Page 4
M7100
Pressure Transducer
DIMENSIONS
Dimensions are in INCHES [mm]
SENSOR SOLUTIONS
///M7100
06/2018
Page 5