OSI
LOW COST CURRENT TRANSFORMERS
FEATURES
FREQUENCY RANGE 50-400 HERTZ
APPLICATIONS
• For use with OSI PC5 series and model W series
Watt/Watthour transducers.
• Ideal for use with Ammeters, relays and Watt
transducers.
• Manufactured to meet requirements of UL 1244
and revisions
• All models on this page UL recognized - file
number E134271.
MODEL SELECTION
50-400 HERTZ CURRENT TRANSFORMER
ACCURACY BURDEN
PART
WT.
AT 60Hz
AT 60Hz
NUMBER (LBS)
(%)
(VA)
50:5
3.0
1.5
10418
1.22
100:5
1.5
5.0
10424
1.28
150:5
1.0
7.5
10421
1.35
200:5
1.0
12.5
10425
1.37
250:5
1.0
12.5
12271
1.39
300:5
1.0
15.0
10417
1.41
400:5
1.0
15.0
10420
1.47
500:5
1.0
25.0
12279
1.53
600:5
1.0
30.0
10422
1.59
750:5
1.0
30.0
12476
1.60
800:5
1.0
35.0
12280
1.61
1000:5
1.0
10.0
10423
0.65
1200:5
1.0
10.0
11014
0.73
1500:5
1.0
12.5
10998
0.86
1600:5
1.0
12.5
12284
1.10
* 2000:5
1.0
15.0
14046
1.10
* NOT UL RATED
CURRENT
RATIO
TRANSFORMER DIMENSIONS (INCHES)
A
4.50
4.50
4.50
4.50
4.50
4.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
B
3.70
3.70
3.70
3.70
3.70
3.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
C
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
D
1.25
1.25
1.25
1.25
1.25
1.25
2.50
2.50
2.50
2.50
2.50
3.00
3.00
3.00
3.00
3.00
E
1.94
1.94
1.94
1.94
1.94
1.94
2.46
2.46
2.46
2.46
2.46
2.46
2.46
2.46
2.46
2.46
G
3.88
3.88
3.88
3.88
3.88
3.88
5.75
5.75
5.75
5.75
5.75
5.75
5.75
5.75
5.75
5.75
J
0.31
0.31
0.31
0.31
0.31
0.31
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
M
0.27x0.44
0.27x0.44
0.27x0.44
0.27x0.44
0.27x0.44
0.27x0.44
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
0.28
DIMENSIONS
SPECIFICATIONS
Frequency....................................................... 50-400Hz
Insulation Class ...................... 0.6kV BIL 10kV full-wave
Lead Wire ..................... UL1015, 105ºC, CSA approved
Size ...........................................16 AWG, 24” length
Termination ................................. No. 8 ring terminal
NOTE: Models with input of 300A and below have slotted
mounting holes.
Caution:
It is recommended that the incoming power be
de-energized before installation. Current Transformer
must have its secondary terminals shorted or the burden
connected BEFORE ENERGIZING the primary.
FOR INDOOR USE ONLY.
Dwg# 0902-00921-B
OHIO SEMITRONICS, INC.
Low Cost Current Transformers Rev D.indd
Page 1 of 1
4242 REYNOLDS DRIVE * HILLIARD, OHIO * 43026-1264
PHONE: (614) 777-1005 * FAX: (614) 777-4511
WWW.OHIOSEMITRONICS.COM
*
1-800-537-6732
4/25/11