Switching Power Supply
S82J
DIN-Rail Mounting Industrial Power
Supplies with Capacity Up to 600 W
D
D
D
D
D
D
D
Models range from 10 to 600 W.
UL 508 approval.
Class 2 approval available for models below 100 W.
Universal input or selectable input.
Wide range of output voltages: 5 V,
12 V, 15 V, or 24 V.
UL, CSA, VDE, and CE Approvals.
3-Year warranty.
Ordering Information
J
OPEN-FRAME TYPE POWER SUPPLIES
Stock Note:
Shaded models are normally stocked.
Rated input voltage
Power
ratings
Output
Voltage
5V
12 V
10 W
15 V
24 V
5V
100 to 240 VAC
12 V
25 W
15 V
24 V
5V
50 W
120 or 240 VAC
(automatically selected)
100 W
100 to 240 VAC
120 or 240 VAC
(automatically selected)
150 W
12 V
24 V
5V
12 V
15 V
24 V
24 V
Current
2A
1A
0.7 A
0.5 A
5A
2.1 A
1.7 A
1.1 A
10 A
4.2 A
2.1 A
20 A
8.5 A
7A
4.5 A
6.5 A
Part number
Front-mounting
bracket
S
82
J-
01005
A
S
82
J-
01012
A
S
82
J-
01015
A
S
82
J-
01024
A
S
82
J-
02505
A
S
82
J-
02512
A
S
82
J-
02515
A
S
82
J-
02524
A
S
82
J-
05005
A
S
82
J-
05012
A
S
82
J-
05024
A
S
82
J-
10005
A
S
82
J-
10012
A
S
82
J-
10015
A
S
82
J-
10024
A
S
82
J-
15024
A
DIN-rail mounting
bracket
S
82
J-
01005
AD
S
82
J-
01012
AD
S
82
J-
01015
AD
S
82
J-
01024
AD
S
82
J-
02505
AD
S
82
J-
02512
AD
S
82
J-02515AD
S
82
J-
02524
AD
S
82
J-
05005
AD
S
82
J-
05012
AD
S
82
J-
05024
AD
S
82
J-
10005
AD
S
82
J-
10012
AD
S
82
J-
10015
AD
S
82
J-
10024
AD
S
82
J-
15024
AD
1
Switching Power Supply
S82J
J
COVERED-FRAME TYPE POWER SUPPLIES
Stock Note:
Shaded models are normally stocked.
Rated input voltage
Power
ratings
Output
Voltage
5V
12 V
10 W
15 V
24 V
5V
100 to 240 VAC
12 V
25 W
15 V
24 V
5V
50 W
120 or 240 VAC
(automatically selected)
100 W
100 to 240 VAC
120 or 240 VAC
(automatically selected)
150 W
12 V
24 V
5V
12 V
15 V
24 V
24 V
Current
2A
1A
0.7 A
0.5 A
5A
2.1 A
1.7 A
1.1 A
10 A
4.2 A
2.1 A
20 A
8.5 A
7A
4.5 A
6.5 A
Part number
Front-mounting
bracket
S
82
J-
01005D
S
82
J-
01012D
S
82
J-
01015D
S
82
J-
01024D
S
82
J-
02505D
S
82
J-
02512D
S
82
J-
02515D
S
82
J-
02524D
S
82
J-
05005D
S
82
J-
05012D
S
82
J-
05024D
S
82
J-
10005D
S
82
J-
10012D
S
82
J-
10015D
S
82
J-
10024D
S
82
J-
15024D
DIN-rail mounting
bracket
S
82
J-
01005
DD
S
82
J-
01012
DD
S
82
J-
01015
DD
S
82
J-
01024
DD
S
82
J-
02505
DD
S
82
J-
02512
DD
S
82
J-02515DD
S
82
J-
02524
DD
S
82
J-
05005
DD
S
82
J-
05012
DD
S
82
J-
05024
DD
S
82
J-
10005
DD
S
82
J-
10012
DD
S
82
J-
10015
DD
S
82
J-
10024
DD
S
82
J-
15024
DD
J
ENCLOSED-FRAME TYPE POWER SUPPLIES
Stock Note:
Shaded models are normally stocked.
Input voltage
120 or 230 VAC (selectable)
Power rating
300 W
600 W
Output
Voltage
24 V
24 V
Current
14.0 A
27.0 A
S82J-30024
S82J-60024
Part number
Note: 1. A mounting bracket is included with each power supply.
2. To order without a mounting bracket (normally included with the 300 W or 600 W), add an “N” at the end of the part number.
3. For other accessories, refer to the
Accessories
section that follows.
Switching Power Supply
S82J
2
J
ACCESSORIES
Stock Note:
Shaded models are normally stocked.
Description
Front-mounting bracket
DIN-rail
Cover
Applicable power supplies
for 100-W, 24-V models
1 m (3.28 ft) length for 10- to 150-W models
0.5 m (1.64 ft) length for 10- to 150-W models
for 10-W models
for 25-W models
for 50-W models
for 100-W, 24-V models
Fan
Ferrite ring core
(a set of 3 pieces in package)
Noise filter
for 600-W models
for 300-W and 600-W models
for 300-W models for 200 to 230 VAC input
for 600-W models for 200 to 230 VAC input
Part number
S82Y-J10F
PFP-100N/PFP-100N2
PFP-50N
S82Y-J01K
S82Y-J02K
S82Y-J05K
S82Y-J10K
S82Y-JFAN
S82Y-JC-T
S82Y-JF3-N
S82Y-JF6-N
J
MODEL NUMBER LEGEND
S82J -
1
1. Power ratings
010: 10 W
025: 25 W
050: 50 W
100: 100 W
150: 150 W
300: 300 W
600: 600 W
2
3
4
2. Output voltage
05: 5 V
12: 12 V
15: 15 V
24: 24 V
3. Configuration
A: Open-frame type, front terminals
B: Covered-type, front terminals
None: Enclosed-type, front terminals
with mounting bracket
4. Mounting Bracket
None: Front-mounting Bracket Type
D:
DIN-rail Mounting Bracket Type
3
Switching Power Supply
S82J
Specifications
Item
100 to 240 VAC input
120 or 240 VAC
(selected
automatically)
50 W
100 W
(24 V)
83% min.
100 W
(5, 12,
15 V)
75%
min.
150 W
120 or 230 VAC
(selectable)
300 W
600 W
10 W
25 W
Efficiency (typical)
Input
Voltage
67% min. (77% min. for 50-W,
24-V models)
100 to 240 VAC
(85 to 264 VAC)
110 to 170 VDC
(set the terminal (L)
to + side)
(See Note 1.)
100 VAC
input
200 VAC
input
100 VAC
input
200 VAC
input
100 VAC
input
200 VAC
input
0.35 A
max.
0.3 A
max.
0.8 A
max.
0.6 A
max.
82% min.
120 (85 to 132) or
230 (170 to 253) VAC
(selectable)
100 to 240 VAC
(85 to 264 VAC)
120 (85 to 132) or
240 (170 to 264)
VAC (selected auto-
matically)
Frequency
Current
(See Note
2.)
Leakage
current (See
Note 2.)
Inrush cur-
rent (25_C,
cold start)
(See Note
2.)
Noise filter
Output (See
Note 3.)
Voltage adjustment
range
Ripple (See Note 2.)
Input variation influence
Load variation influence
Temperature variation
influence
Startup time
50/60 Hz (47 to 450 Hz)
1.4 A
max.
0.8 A
max.
2.5 A
max.
1.15 A
max.
2.5 A
max.
1.4 A
max.
3.5 A
max.
2.1 A
max.
8 A max.
4 A max.
14 A max.
7 A max.
0.5mA max.
1mA max.
25 A max.
50 A max.
Yes
10%
(adjustable with variable resistor (V.ADJ))
2% (p-p) max.
0.4% max
0.8% max. (with rated input, 10% to 100% load)
0.05%/_C max. (with rated input and output)
500 ms max. (up to 90% of output voltage at rated input and out-
put)
300 ms max. (up to
90% of output voltage
at rated input and out-
put)
30 A max.
60 A max.
Hold time (See Note 2.)
Additional
function
Overload protection
20 ms min.
105% to 160% of rated load current, in-
verted L drop/intermittent operation type,
automatic reset
105% min. of rated load current, inverted L drop
type, automatic reset (For the 600-W model, the
circuit will be shut OFF when the overload ex-
ceeds 5s. Protection-ON alarm indicator lit (See
Note 5.)
Yes (5-V
output
models
only)
(See
Note 4.)
No
Yes, protection-ON
alarm indicator lit (See
Note 5.)
Overvoltage protection
NO
Yes (See
Note 4.)
Overheat protection
No
Yes, protec-
tion ON
alarm indi-
cator lit (See
Note 5.)
(This table continues on the next page.)
Switching Power Supply
S82J
4
Specifications Table
– continued from previous page
Item
100 to 240 VAC input
120 or 240 VAC
(selected
automatically)
50 W
100 W
(24V)
100 W
(5, 12,
15 V)
150 W
120 or 230 VAC
(selectable)
300 W
600 W
10 W
25 W
Additional
function
Protection-ON alarm
indicator
Parallel operation
Series operation
No
No
No
Yes
See the derating curve in the Engineering Data Section.
-25_C to 65_C (-13_F to 149_F) with no condensation and icing
25% to 85%
25% to 90%
3.0 k VAC, 50/60 Hz for 1 min (between all inputs and all outputs)
2.2 k VAC, 50/60 Hz for 1 min (between all inputs and GR terminal)
1.0 k VAC, 50/60 Hz for 1 min (between all outputs and GR terminal)
Yes (color, red)
Yes, 5 units max.
Other
Ambient
temperature
Ambient
humidity
Operat-
ing
Storage
Operat-
ing
Storage:
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Terminal screw
tightening
Output indicator
Electromagnetic interfer-
ence (See Note 2.)
EMC
100 MW min. (between all outputs and all inputs/GR terminals at 500 VDC)
10 to 55 Hz, 0.375-mm double amplitude for 2 h each in X, Y, and Z directions
300 m/s
2
, 3 times each in
X, Y,
and
Z
directions
0.74 N
m
Yes (green)
Conforms to FCC Class A
Emission Enclosure: EN55011 class A
Emission AC Mains: EN55011 class A
Immunity ESD:
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: ENV50140: 10 Vm (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.5 to 80 MHz) (level 3)
Immunity Burst
EN61000-4-4
2 kV power-line (level 3)
2 kV output line (level 4)
Conforms to EN50081-2 and EN50082-2
Conforms to
EN50081-2 and
EN50082-2 (See Note
6.) With noise filter,
confirms to EN50081-1
(See Note 6 and 7.)
UL508/1012
CSA EB1402C
1.08 N
m
EMC standards
Approved
standards
UL
CSA
VDE
UL508 (Listing), 1950, Class 2
(per UL1310) (See Note 8.)
CSA C22.2 No. 14, No. 950,
Class 2 (See Note 8.)
UL508 (Listing), 1012, 1950
CSA C22.2 No. 14, No. 950
EN50178 (VDE0160) and EN60950
Terminal types (only terminal part): VDE0106/P100
250 g
max.
350 g
max.
400 g
max.
500 g
max.
1,000 g max
2,000 g
max.
2,500 g
max.
Weight (See Note 9.)
Mean time between
failures
Life expectancy
Note: 1.
2.
3.
4.
5.
6.
7.
8.
9.
135,000 hrs min. (MTBF is calculated according to the probability of accidental device fail-
ures, and indicates reliability of devices. It does not necessarily represent a life of the product.
10 yrs. min. (Used at 40_C at the rated input with a 50% load, standard installation).
DC inputs are not included in safety standard approvals.
At 100% load for rated input voltage (100 VAC or 200 VAC)
The output specification is defined at the power supply output terminals.
For resetting, turn OFF the power supply, leave for more than one minute, and then turn ON the power supply.
For resetting, turn OFF the power supply, leave for more than 90 seconds min. (3 minutes for the 600-W models), and then turn
ON the power supply.
To ensure the Emission Enclosure rating ferrite ring cores (recommended model: S82Y-JC-T) should be used on all cabling.
To ensure the Emission AC Mains rating for EN50081-1 (only for 230 VAC input), a noise filter (recommended models:
S82Y-JF3-N for 300-W, S82Y-JF6-N for 600-W) should be used on the input lines.
Class 2 approval on 10-W (12, 15, 24 V), 25-W (12, 15, 24 V) and 50-W (24 V) models.
The weight indicated is the weight of the open-frame type. (Includes the covers for 300-W and 600-W models)
5
Switching Power Supply
S82J