Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8641 Multi-Conductor - Single-Pair Cable
For more Information
please call
1-800-Belden1
Description:
24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil shield (100%
coverage), 24 AWG stranded TC drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
24
7x32
TC - Tinned Copper
Total Number of Conductors:
2
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PE - Polyethylene
0.017
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24
7x32
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .025
Overall Cable
Overall Nominal Diameter:
0.168 in.
Pair
Pair Color Code Chart:
Number Color
1
Black & Clear
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +80°C
60°C (UL AWM Style 2092)
12 lbs/1000 ft.
11 lbs.
1.750 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CM
Page 1 of 3
09-04-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8641 Multi-Conductor - Single-Pair Cable
CEC/C(UL) Specification:
AWM Specification:
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CM
UL Style 2092 (300 V 60°C)
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N):
Plenum Number:
No
88641, 82641
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
80
Nom. Inductance:
Inductance (µH/ft)
.22
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
22
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
42
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
25
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
14.6
Max. Operating Voltage - UL:
Voltage
300 V RMS (UL AWM Style 2092)
Max. Recommended Current:
Current
2.2 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
8641 060U1000
8641 060U500
8641 060100
8641 0601000
8641 0602000
8641 060500
Putup
1,000 FT
500 FT
100 FT
1,000 FT
2,000 FT
500 FT
Ship Weight
14.000 LB
7.500 LB
2.000 LB
14.000 LB
28.000 LB
7.000 LB
Color
CHROME
CHROME
CHROME
CHROME
CHROME
CHROME
C
C
Notes
Item Desc
1 #24 FS PR PE PVC
1 #24 FS PR PE PVC
1 #24 FS PR PE PVC
1 #24 FS PR PE PVC
1 #24 FS PR PE PVC
1 #24 FS PR PE PVC
Page 2 of 3
09-04-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8641 Multi-Conductor - Single-Pair Cable
8641 0605000
Notes:
C = CRATE REEL PUT-UP.
5,000 FT
65.000 LB
CHROME
1 #24 FS PR PE PVC
Revision Number: 2
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 08-14-2012
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3