EEWORLDEEWORLDEEWORLD

Part Number

Search

TA35-C087FC00-CZM21

Description
Thermal Circuit Breaker, 2 Pole(s), 240VAC, 60VDC, Panel Mount,
CategoryCircuit protection    Circuit protection   
File Size1001KB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

TA35-C087FC00-CZM21 Overview

Thermal Circuit Breaker, 2 Pole(s), 240VAC, 60VDC, Panel Mount,

TA35-C087FC00-CZM21 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1978168094
Reach Compliance Codenot_compliant
YTEOL9.1
Actuator typeROCKER
body width26 mm
body height43.9 mm
Body length or diameter39 mm
circuit functionTRIP FREE
Circuit protection typeTHERMAL CIRCUIT BREAKER
Environmental characteristicsIP40
Installation featuresPANEL MOUNT
Number of poles2
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
Rated breaking capacity2000 A
Rated voltage (AC)240 V
Rated voltage (DC)60 V
GuidelineCCC; CSA; CUL; GB; IEC; UL; VDE
surface mountNO
Terminal shapeQUICK CONNECT
Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
Circuit Breaker for Equipment thermal, Rocker actuation, 2 pole
TA35 Rocker 2Pole
Description
-
-
-
-
-
-
-
-
-
-
-
Thermal circuit breaker
2-pole
Snap-in version
Positively trip-free release
Different rocker colours
High configurability
Wide current range
IEC 60934
UL 1077
CSA C22.2 235
GB 17701
Characteristics
-
-
-
-
-
Power tools
Industrial appliances
Equipment for construction
Cleaning equipment
Commercial and household kitchen appliances
Weblinks
Standards
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit ca-
pacity
Degree of Protection
Dielectric Strength
Insulation resistance
Endurance typical
240 V; 50/60 Hz
60 V
0.05 - 20 A
0.05...20 A: 2 kA, SC (C1) @ 240 VAC
from front side IP 40 acc. to IEC 60529
50 Hz: > 2.5 kV
Impulse 1.2/50
μs:
> 4 kV
500 VDC > 100 MΩ
mechanical: 50'000 switching cycles
AC: 1 x Ir, cos
φ
0.6:
50'000 switching cycles
DC: 1 x Ir, L/R = 2 - 3 ms:
50'000 switching cycles
Overload
Ambient temperature
Vibration Resistance
IEC: min. 40 trips
@ 6 x Ir, cos
φ
0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos
φ
0.75
-30 °C to 60 °C
± 0.75 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Tc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Tc
30 G / 18 ms
acc. to IEC 60068-2-27, test Ea
Thermal
29.0 - 31.5 g
Shock Resistance
Tripping Type
Weight
Dimension
36
34
7.2
1.7
29
20.9
26
+0.2
0
+0.3
44.1
10.5
LINE
10.6
34
Panel 1.0 − 4.0 mm
L
21.3
33.8
2.3
11 6.1
23.5
26
6.3 x 0.8 mm
33.5
Circuit Breakers
+0.2
0
1

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号