cir brkr thrm 3A 200vac 28vdc

High Performance Thermal Circuit Breaker 583-...
Description
Three pole, miniaturised, aircraft style thermal circuit breaker with
tease-free, trip-free, snap action mechanism and push/pull on/off
manual actuation (M-type TO CBE to EN 60934). An indicator band
on the push button clearly shows the tripped/off position. Threadneck
panel mounted, available in metric and US (AS 14154) configurations.
Advanced two-chamber design minimises contact contamination to
provide fail-safe operation. Temperature compensated with optional
auxiliary contacts, and fully approved for use on a wide range of
aircraft and equipment.
Various dummies are available without protective function, allowing
connection of pre-installed wiring without loads.
Typical applications
Aircraft systems and equipment (fixed wing and helicopters); other extra
low voltage wiring applications; defence equipment; communications
systems.
without auxiliary contact
583-...
with auxiliary contact
Technical data
Voltage rating
Current rating range
Auxiliary circuit
Typical life
3 AC 200 V (300 Hz to 800 Hz); DC 28 V
1...30 A
0.5 A, DC 28 V
20,000 operations mechanical
10,000 operations at I
N
(≤ 25 A)
4,000 operations at I
N
(30 A)
-55...+125 °C (-67...+257 °F) ≤ 15 A
-55...+90 °C (-67...+194 °F) > 15 A
rated impulse
pollution
withstand voltage
degree
1.5 kV
3
test voltage
AC 1,500 V
AC 1,500 V
AC 1,500 V
> 100 MΩ (DC 500 V)
Standard current ratings and typical volt drop values
Current
rating (A)
1
2
2.5
3
4
5
Volt drop per
pole (mV)
750
520
400
360
350
260
Current
rating (A)
7.5
10
15
20
25
30
Volt drop per
pole (mV)
230
190
190
200
170
160
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Dielectric strength
(IEC 60664 and 60664A)
operating area
pole/pole
main to aux. circuit
Insulation resistance
Interrupting capacity I
cn
3 AC 200 V (400 Hz):
Approvals
Authority
Bw
Airbus
Airbus
Bw
Standard
LN 29887
EN 2996-004
EN 2996-005
VG 95345-11
Voltage ratings
AC 115/200 V
400 Hz
AC 115/200 V
400 Hz
AC 115/200 V
400 Hz
AC 115/200 V
400 Hz bzw.
DC 28 V
AC 115/200 V
400 Hz
Current ratings
5 … 25 A
1 … 25 A
1 … 25 A
1 … 25 A
Dept. of
the Navy
AS14154
1 … 20A
≤4A
1,000 A
5A
2,000 A
7.5...25 A 2,500 A
30 A
1,500 A
DC 28 V: 1...25 A
6,000 A
30 A
4,000 A
Degree of protection
operating area IP40
(IEC 60529/DIN 40050)
terminal area IP00
Vibration
10 g (57-2000 Hz), ± 0.76 mm (5-57 Hz)
(sinusoidal)
to VG 95210, sheet 19,
IEC 60068-2-6, test Fc, ISO 7137
Vibration (random)
16.4 g rms, 0.2 g
2
Hz ± 1.5 dB,
to VG 95210, sheet 29,
IEC 60068-2-6, test Fc, ISO 7137
Acceleration
17 g, to ISO 2669
Shock
50 g (11 ms), to VG 95210, sheet 28,
IEC 60068-2-27, test Ea, ISO 7137
Corrosion
96 hours at 5 % salt mist
48 hours at 20 % salt mist
to VG 95210, sheet 2,
IEC 60068-2-11, test Ka, ISO 7137
Humidity
240 hours at 95 % RH,
to VG 95210, sheet 7,
IEC 60068-2-3, test C/ISO 7137
Explosion
to VG 95210, sheet 10,
MIL-STD-202, meth. 109
Altitude
≤ 25,000 m above sea level
Mass
max. 67 g with auxiliary contact
max. 63 g without auxiliary contact
Mass reduction through aluminium threadneck approx. 3 g
5
2015/16
www.e-t-a.de
5
- 55
Six high-end air-cooled radiators are recommended to challenge the cooling limit
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:58[/i]...
lorant Mobile and portable
Implementation of a car walking through a maze based on GD32F350
[i=s]This post was last edited by sunyongshuai on 2018-9-30 22:30[/i] [align=left][b][size=22pt][font=SimSun]Design of intelligent car walking through maze based on[/font]GD32F350[font=SimSun][/font][...
sunyongshuai GD32 MCU
Waveform diagram problem of volt-second law
[Ask if you don't understand] The figure is a waveform diagram about the volt-second product law, from "Mastering Switching Power Supply Design" (Second Edition). Von represents the inductor voltage w...
shaorc Power technology
[Audio recognizer based on GD32F350RB] 3. CMSIS-NN neural network configuration analysis
[i=s]This post was last edited by Beifang on 2018-9-21 10:14[/i] 1. After completing the basic test, you can analyze the program and logic of this specific implementation in detail. As shown in the fo...
北方 GD32 MCU
msp432 record 1-gpio usage
In fact, the documentation in the SDK has already explained the usage very clearly, recording some problems The declaration of GPIO typedef enum MSP_EXP432P401R_GPIOName in msp_exp432p401r.hcorrespond...
fish001 Microcontroller MCU
[Environmental Expert’s Smart Watch] Part 18: Downhole Mode
1. Introduction Because the watch can be worn daily, a mechanism is needed to switch modes. The [RSL10-SENSE-GEVK] development kit has two buttons, so these two buttons can be used for design. The sce...
w494143467 onsemi and Avnet IoT Innovation Design Competition

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号