EEWORLDEEWORLDEEWORLD

Part Number

Search

ECM100UT33

Description
AC/DC converter 5V +/-15v 100w
CategoryPower/power management    The power supply circuit   
File Size359KB,6 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Environmental Compliance
Download Datasheet Parametric View All

ECM100UT33 Online Shopping

Suppliers Part Number Price MOQ In stock  
ECM100UT33 - - View Buy Now

ECM100UT33 Overview

AC/DC converter 5V +/-15v 100w

ECM100UT33 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerXP Power
package instruction,
Reach Compliance Codecompliant
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
CertificationCSA, EN, UL
Efficiency (main output)85%
high30.5 mm
Maximum input voltage264 V
Minimum input voltage90 V
length114.3 mm
Maximum grid adjustment rate0.5%
Maximum load regulation3%
Maximum operating temperature70 °C
Minimum operating temperature
Maximum output current10 A
Nominal output voltage5 V
ProtectOUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
Maximum total power output40 W
width63.5 mm
AC DC
40 100 Watts
ECM Series
Compact Size
IT & Medical Approvals
Convection cooled
Class I and II Construction
xppower.com
DC Input Version Available (DCM Series)
PoE Isolation Version Available (POE Series)
3 Year Warranty
Specification
Input
• 90-264 VAC (120-370 VDC)
• 47-63 Hz; 440 Hz*
• 40 W: 0.4 A max at 230 VAC
60 W: 0.6 A max at 230 VAC
100 W: 0.9 A max at 230 VAC
Inrush
Current
• 40 A max at 230 VAC
Earth Leakage Current
• <125 µA at 115 VAC/60 Hz
<210 µA at 230 VAC/50 Hz
Power Factor
• EN61000-3-2
Input Protection
• Internal T3.15 A, 250 V fuse in line
and neutral
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
• 80-85% depending on model
• 4000 VAC Input to Output 2 x MOPP
ECM100 single output models, 1 x MOPP
ECM100 multi output and all ECM40/60
models (contact sales for 2 x MOPP),
1500 VAC Input to Ground 1 x MOPP,
500 VAC Output to Ground
• 70 kHz typical
• 40 W: 4.2 W/In
3
60 W: 6.3 W/In
3
100 W: 7.4 W/In
3
• 600 kHrs to MIL-HDBK-217F
at 25 °C, GB
Switching Frequency
Power Density
MTBF
Output
• See tables
• ±5% on 3.3 V & 5 V versions, ±10% on
other single output models and V1 of
multi-output models. (See note 1 for
ECM40/60 models)
Initial Set Accuracy
• ±1.0% V1, ±5% V2, V3 & V4
Minimum Load
• See tables
Start Up Delay
• 1.5 s max
Start Up Rise Time
• 10 ms max
Hold Up Time
• 16/75 ms min at 115/230 VAC
Line Regulation
• ±0.5%
Load Regulation
• ±1% single output models;
±3% V1, ±5% V2 & V3 ECM40/60
multi-output models.
±1% V1 & V2, ±5% V3 & V4 ECM100
Cross Regulation
• 2% on ECM40/60 only
Over/Undershoot
• None at turn on/off
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection
• 115-135% Vnom, recycle input to reset
Overload Protection
• 110-150% on primary power limit,
auto recovery
Short Circuit Protection
• Trip and restart (hiccup mode)
Temperature
• 0.05%/°C
Coefficient
Peak Load
• 120% for 100 ms ECM40/60 (see note 3)
Output Voltage
Output Voltage Trim
* Safety approvals cover frequency range 47-63 Hz
Environmental
Operating Temperature
• 0 °C to +70 °C. Refer to derating curves
for specific operating limitations.
Cooling
• Convection & fan-cooled ratings
(see derating curves)
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Emissions
• EN60601-1-2, EN61204-3, FCC 20780,
EN55022 & EN55011, level B conducted
EN55022 Level A radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A,
SEMI F47
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60601-1, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf Criteria A, A (with 50% load), A, B
• EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No.60601-1 per cUL, Including
Risk Management, EN60950-1, UL60950-1
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号