AC DC
40 100 Watts
ECM Series
•
•
•
•
•
•
•
Compact Size
IT & Medical Approvals
Convection cooled
Class I and II Construction
xppower.com
DC Input Version Available (DCM Series)
PoE Isolation Version Available (POE Series)
3 Year Warranty
Specification
Input
• 90-264 VAC (120-370 VDC)
• 47-63 Hz; 440 Hz*
• 40 W: 0.4 A max at 230 VAC
60 W: 0.6 A max at 230 VAC
100 W: 0.9 A max at 230 VAC
Inrush
Current
• 40 A max at 230 VAC
Earth Leakage Current
• <125 µA at 115 VAC/60 Hz
<210 µA at 230 VAC/50 Hz
Power Factor
• EN61000-3-2
Input Protection
• Internal T3.15 A, 250 V fuse in line
and neutral
Input Voltage
Input Frequency
Input Current
General
Efficiency
Isolation
• 80-85% depending on model
• 4000 VAC Input to Output 2 x MOPP
ECM100 single output models, 1 x MOPP
ECM100 multi output and all ECM40/60
models (contact sales for 2 x MOPP),
1500 VAC Input to Ground 1 x MOPP,
500 VAC Output to Ground
• 70 kHz typical
• 40 W: 4.2 W/In
3
60 W: 6.3 W/In
3
100 W: 7.4 W/In
3
• 600 kHrs to MIL-HDBK-217F
at 25 °C, GB
Switching Frequency
Power Density
MTBF
Output
• See tables
• ±5% on 3.3 V & 5 V versions, ±10% on
other single output models and V1 of
multi-output models. (See note 1 for
ECM40/60 models)
Initial Set Accuracy
• ±1.0% V1, ±5% V2, V3 & V4
Minimum Load
• See tables
Start Up Delay
• 1.5 s max
Start Up Rise Time
• 10 ms max
Hold Up Time
• 16/75 ms min at 115/230 VAC
Line Regulation
• ±0.5%
Load Regulation
• ±1% single output models;
±3% V1, ±5% V2 & V3 ECM40/60
multi-output models.
±1% V1 & V2, ±5% V3 & V4 ECM100
Cross Regulation
• 2% on ECM40/60 only
Over/Undershoot
• None at turn on/off
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection
• 115-135% Vnom, recycle input to reset
Overload Protection
• 110-150% on primary power limit,
auto recovery
Short Circuit Protection
• Trip and restart (hiccup mode)
Temperature
• 0.05%/°C
Coefficient
Peak Load
• 120% for 100 ms ECM40/60 (see note 3)
Output Voltage
Output Voltage Trim
* Safety approvals cover frequency range 47-63 Hz
Environmental
Operating Temperature
• 0 °C to +70 °C. Refer to derating curves
for specific operating limitations.
Cooling
• Convection & fan-cooled ratings
(see derating curves)
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 °C to +85 °C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Emissions
• EN60601-1-2, EN61204-3, FCC 20780,
EN55022 & EN55011, level B conducted
EN55022 Level A radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A,
SEMI F47
• EN61000-4-6, 10 V Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60601-1, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf Criteria A, A (with 50% load), A, B
• EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No.60601-1 per cUL, Including
Risk Management, EN60950-1, UL60950-1
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
AC DC
Models and Ratings
Output 1
Output Power
Voltage
5.0
7.0
9.0
12.0
15.0
18.0
24.0
33.0
48.0
+5.0
+5.0
+5.0
+5.0
+5.0
+3.3
+5.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Current
Min/Max
(3)
0.0 A/8.0 A
0.0 A/5.7 A
0.0 A/4.4 A
0.0 A/3.5 A
0.0 A/2.7 A
0.0 A/2.2 A
0.0 A/1.7 A
0.0 A/1.2 A
0.0 A/0.9 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
0.5 A/6.0 A
Voltage
Output 2
Current
Min/Max
Voltage
Output 3
ECM40
Current
Min/Max
Model Number
(2)
ECM40US05
ECM40US07
ECM40US09
ECM40US12
ECM40US15
ECM40US18
ECM40US24
ECM40US33
ECM40US48
ECM40UD21
ECM40UD22
ECM40UT31
ECM40UT32
ECM40UT33
ECM40UT34
ECM40UT35
40 W
+12.0
+15.0
+12.0
+24.0
+15.0
+5.0
+3.3
V
V
V
V
V
V
V
0.1
0.1
0.1
0.1
0.1
0.1
0.1
A/2.0
A/1.5
A/2.0
A/1.0
A/1.5
A/1.5
A/1.5
A
A
A
A
A
A
A
-12.0
-12.0
-15.0
+12.0
+12.0
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A
A
A
A
A
Notes
1. V2 will track a change in V1 by the same percentage change in voltage as V1 is trimmed.
2. To receive unit with cover fitted, add suffix ‘-C’ to model number. For Class I operation only.
3. A 120% peak load can be taken for up to 100 ms with a 25% duty cycle. Average load not to exceed 40 W.
Mechanical Details
4.00 (101.6)
3.75 (95.25)
1.20 (30.5)
Input Connector J1
Pin 1
Line
Pin 2
Neutral
J1 mates with
Molex housing 43061-0003 &
Molex series 5194 crimp terminals
Ground tab (0.25 faston) standard
Output Connector J2
Pin
Single
Multi
1
V1
+V1
2
V1
+V1
3
RTN
RTN
4
RTN
RTN
5
NC
V3
6
NC
+V2
J2 mates with
Molex housing 43061-0006 &
Molex series 5194 crimp terminals
1
2.00
(50.8)
1.75
(44.45)
J2
6
0.25 x 0.32 faston ground tab
4 x ø0.156 (3.96) mounting holes
ø0.312 (7.92) clearance top and bottom
V Adj.
0.14 (3.5)
SMD component height
Notes
1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
2. Weight: approx. 0.33 lbs (150 g)
3. Cable harnessess with 300 mm wire available.
For single output models, order part number ECM40/60S LOOM†.
For multi-output models, order part number ECM40/60DT LOOM†^.
4. Mating connector kit available. Order part number ECM40/60 CONKIT†.
5. Covers available. Order part number ECM40/60 COVER†^.
Cover dimensions are 4.49 x 2.52 x 1.52 (114 x 64 x 38.5)
6. 3D drawing files available from www.xppower.com/cad.php.
Derating Curves
All ECM40 models convection cooled
All ECM40 models with 5 CFM
100%
Output Power
Output Power
0
30
40
50
60
70
80
75%
50%
25%
0%
10
20
Ambient Temp (°C)
100%
75%
50%
25%
0%
0
10
20
30
40
50
60
70
80
Ambient Temp (°C)
Note: Derate by 10% if cover is fitted
Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications.
AC DC
Models and Ratings
Output 1
Output Power
Voltage
5.0
7.0
9.0
12.0
15.0
18.0
20.0
24.0
28.0
33.0
48.0
+5.0
+5.0
+5.0
+5.0
+5.0
+3.3
+5.0
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
Current
Min/Max
(3)
0.0 A/12.00 A
0.0 A/8.60 A
0.0 A/6.70 A
0.0 A/5.00 A
0.0 A/4.00 A
0.0 A/3.30 A
0.0 A/3.00 A
0.0 A/2.50 A
0.0 A/2.14 A
0.0 A/1.80 A
0.0 A/1.25 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
0.5 A/8.00 A
Voltage
Output 2
Current
Min/Max
Voltage
Output 3
ECM60
Current
Min/Max
Model Number
(2)
ECM60US05
ECM60US07
ECM60US09
ECM60US12
ECM60US15
ECM60US18
ECM60US20
ECM60US24
ECM60US28
ECM60US33
ECM60US48
ECM60UD21
ECM60UD22
ECM60UT31
ECM60UT32
ECM60UT33
ECM60UT34
ECM60UT35
60 W
+12.0
+15.0
+12.0
+24.0
+15.0
+5.0
+3.3
V
V
V
V
V
V
V
0.1
0.1
0.1
0.1
0.1
0.1
0.1
A/3.0
A/2.5
A/3.0
A/1.5
A/2.5
A/1.5
A/1.5
A
A
A
A
A
A
A
-12.0 V
-12.0 V
-15.0 V
+12.0 V
+12.0 V
0.0
0.0
0.0
0.0
0.0
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A
A
A
A
A
Notes
1. V2 will track a change in V1 by the same percentage change in voltage as V1 is trimmed.
2. To receive unit with cover fitted, add suffix ‘-C’ to model number. For Class I operation only.
3. A 120% peak load can be taken for up to 100 ms with a 25% duty cycle. Average load not to exceed 60 W.
Mechanical Details
4.00 (101.6)
3.75 (95.25)
1.20 (30.5)
Input Connector J1
Pin 1
Line
Pin 2
Neutral
J1 mates with
Molex housing 43061-0003 &
Molex series 5194 crimp terminals.
Ground (0.25 faston) tab standard.
Output Connector J2
Single
Multi
V1
+V1
V1
+V1
RTN
RTN
RTN
RTN
NC
V3
NC
+V2
1
2.00
(50.8)
1.75
(44.45)
J2
6
0.25 x 0.32 faston ground tab
4 x ø0.156 (3.96) mounting holes
ø0.312 (7.92) clearance top and bottom
V Adj.
0.14 (3.5)
SMD component height
Pin
1
2
3
4
5
6
J2 mates with
Molex housing 43061-0006 &
Molex series 5194 crimp terminals.
Notes
1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
2. Weight: 0.33 lbs (150 g) approx.
3. Cable harnesses with 300 mm wire available.
For single output models, order part number ECM40/60S LOOM†.
For multi-output models, order part number ECM40/60DT LOOM†.
4. Mating connector kit available. Order part number ECM40/60 CONKIT†.
5. Covers available. Order part number ECM40/60 COVER^†. Cover dimensions
are 4.49 x 2.52 x 1.52 (114 x 64 x 38.5).
6. Selected single output models available in a 3” x 5” footprint for OEM
quantities. Contact sales for details.
7. 3D drawing files available from www.xppower.com/cad.php.
Derating Curves
All ECM60 models convection cooled
All ECM60 models with 5 CFM
100%
Output Power
0
10
20
30
40
50
60
70
80
Output Power
75%
50%
25%
0%
Ambient Temp (°C)
100%
75%
50%
25%
0%
0
10
20
30
40
50
60
70
80
Note: Derate by 10% if cover is fitted
Ambient Temp (°C)
Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications.
AC DC
Models and Ratings
Single Output Models
Output
Voltage
3.3 V
5.0 V
7.0 V
9.0 V
12.0 V
15.0 V
18.0 V
24.0 V
28.0 V
33.0 V
48.0 V
Minimum
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
Output 1
Current
Voltage
Min/Max
+5.0 V
0.0 A/12.0 A
+5.0 V
0.0 A/12.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+3.3 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+3.3 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
+5.0 V
0.5 A/10.0 A
Output Current
Maximum
15.0 A
15.0 A
11.4 A
8.8 A
7.5 A
6.0 A
5.0 A
4.1 A
3.6 A
3.0 A
2.1 A
Output 2
Current
Voltage
Min/Max
+12.0 V
0.0 A/3.0 A
+15.0 V
0.0 A/3.0 A
+12.0 V
0.0 A/3.0 A
+24.0 V
0.0 A/2.0 A
+15.0 V
0.0 A/3.0 A
+5.0 V
0.0 A/5.0 A
+3.3 V
0.0 A/5.0 A
+12.0 V
0.0 A/3.0 A
+15.0 V
0.0 A/3.0 A
+3.3 V
0.1 A/5.0 A
+5.0 V
0.1 A/5.0 A
+24.0 V
0.1 A/2.0 A
+24.0 V
0.1 A/2.0 A
+12.0 V
0.1 A/3.0 A
+15.0 V
0.1 A/3.0 A
with 5 CFM Cooling
20.0 A
20.0 A
14.3 A
11.1 A
8.3 A
6.6 A
5.5 A
4.1 A
3.6 A
3.0 A
2.1 A
ECM100
Model Number
(1)
ECM100US03
ECM100US05
ECM100US07
ECM100US09
ECM100US12
ECM100US15
ECM100US18
ECM100US24
ECM100US28
ECM100US33
ECM100US48
Multi Output Models
Output Power
Convection Forced Air
Cooled
5 CFM
80 W
100 W
80 W
100 W
75 W
100 W
80 W
100 W
80 W
100 W
65 W
100 W
70 W
100 W
80 W
100 W
70 W
100 W
65 W
100 W
60 W
100 W
80 W
100 W
80 W
100 W
80 W
100 W
80 W
100 W
Output 3
Current
Voltage
Min/Max
Output 4
Current
Voltage
Min/Max
Model Number
(1)
ECM100UD21
ECM100UD22
ECM100UT31
ECM100UT32
ECM100UT33
ECM100UT34
ECM100UT35
ECM100UT36
ECM100UT37
ECM100UQ41
ECM100UQ42
ECM100UQ43
ECM100UQ44
ECM100UQ45
ECM100UQ46
-12.0
-12.0
-15.0
+12.0
+12.0
-5.0
-5.0
+12.0
+12.0
+12.0
+15.0
-12.0
-15.0
V
V
V
V
V
V
V
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A/0.8
A
A
A
A
A
A
A
A
A
A
A
A
A
-12.0
-12.0
-12.0
-15.0
-5.0
-5.0
V
V
V
V
V
V
0.0
0.0
0.0
0.0
0.0
0.0
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A/0.5
A
A
A
A
A
A
Notes
1. To receive unit with cover fitted, add suffix ‘-C’ to model number. For Class I
operation only.
2. Output 3 available with opposite polarity for OEM quantities.
Mechanical Details
4.50 (114.3)
0.12 (3.2)
4.25 (107.9)
1.20 (30.5)
Pin 1
Pin 2
Input Connector J1
Line
Neutral
J1 mates with Molex housing 43061-0003 and Molex series
5194 crimp terminals. Ground (0.25 faston) tab standard.
2.50
(63.5)
2.25
(57.1)
J1
1
2
1
J2
1.27
(32.2)
12
2.10
(53.3)
1.25 (3.2)
0.20
(5.1)
0.25 faston ground tab
V Adj.
0.20
(5.1)
0.14 (3.5)
SMD component height
4X ø0.16 (4.0) mounting holes
ø0.31 (7.9) clearance top and bottom
Cover dimensions are 4.98 x 3.01 x
1.54 (126.5 x 76.4 x 39.0)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
Output Connector J2
Single
V1
V1
V1
V1
V1 RTN
V1 RTN
V1 RTN
V1 RTN
NOT USED
NOT USED
NOT USED
NOT USED
Multi
+V1
+V1
+V1
+V1
RTN
RTN
RTN
RTN
+V2
+V2
±V3
-V4
1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
2. Weight: 0.4 lbs (180 g) approx.
3. Cable harnessess with 300 mm wire available. For single output models, order
part number ECM100S LOOM†. For multi-outputs (dual and triple output only),
p/n ECM100DT LOOM†.
Notes
J2 mates with Molex housing 43061-0012 and Molex
series 5194 crimp terminals.
4. Mating connector kit available for single output models. Order part number
ECM100S CONKIT†^.
5. Covers available. Order part number ECM100 COVER†^.
6. Available in a 3” x 5” footprint for OEM quantities. Contact sales for details.
7. 3D drawing files available from www.xppower.com/cad.php.
Derating Curves
All ECM100 single output models convection cooled
100
Output Power (W)
80
60
40
20
0
0
10
20
30
40
50
60
70
80
Ambient Temp (°C)
C
D
B
A
A US24-48
B US12-18
C US05
D US03
All ECM100 models with 5 CFM
Output Power
100%
75%
50%
25%
0%
0
10
20
30
40
50
60
70
80
Ambient Temp (°C)
Note:
1. Derate by 10% if cover is fitted.
2. For multi output convection-
cooled operation above +50 °C
derate linearly to 50% at +70 °C.
Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications.
AC DC
Models and Ratings
Input Voltage Range
(1)
36-76 VDC
(48 VDC Nominal)
Input Current
1.5 A (2.5 A max)
2.2 A (3.5 A max)
UVLO
Output
Voltage
12 V
12 V
Output Current
Max
Convection
-cooling
5.00 A
7.50 A
DCM60/100
Min
(6)
0.25 A
0.40 A
Max - 5CFM
forced
-cooling
5.00 A
8.30 A
Model Number
DCM6048S12
DCM10048S12
32 - 35 VDC
1. Can be configured as -48 VDC input.
2. Input reverse voltage protection is continuous with automatic recovery.
3. Input transients compliant with ETSI EN300 132:2003.
Notes
4. For a fitted cover version, add suffix ‘-C’ to model number (power derates by
20% with cover fitted)
5. For full product details contact sales, or visit www.xppower.com
6. 5% minimum load required to meet all specification parameters
Mechanical Details
DCM60
4.00 (101.6)
3.75 (95.2)
1.20 (30.5)
0.125 (3.2)
Input Connector J1
Pin 1
-Vin
Pin 2
+Vin
J1 mates with
Molex housing 43061-0003 &
Molex series 5194 crimp terminals
1
2.00
(50.8)
1.75
(44.4)
2
J1
1
6
+
J2
1.61 (41.0)
0.87 (22.2)
Voltage Adjust
Ground Connection through
mounting holes
0.12 (3.2)
0.20 (5.1)
0.21 (5.4)
0.14 (3.5)
SMD Component Height
4 x 0.15 (3.9) mounting holes
ø0.31 (7.9) clearance top and bottom
Output Connector J2
Pin
Single
1
12V
2
12V
3
RTN
4
RTN
5
NC
6
NC
J2 mates with
Molex housing 43061-0006 &
Molex series 5194 crimp terminals
-
DCM100
4.50 (114.3)
0.12 (3.2)
4.25 (107.9)
1.20 (30.5)
Input Connector J1
Pin 1
-Vin
Pin 2
+Vin
J1 mates with
Molex housing 43061-0003 &
Molex series 5194 crimp terminals
1
2.50
(63.5)
2.25
(57.1)
J1
+
2
1
J2
2.10 (53.3)
1.29 (32.8)
12
0.12 (3.2)
0.20 (5.1)
4 x 0.15 (3.9) mounting holes
ø0.31 (7.9) clearance top and bottom
Voltage Adjust
Ground Connection through
mounting holes
0.20 (5.1)
0.14 (3.5)
SMD Component Height
Output Connector J2
Pin
Single
1
12V
2
12V
3
12V
4
12V
5
RTN
6
RTN
7
RTN
8
RTN
9
NC
10
NC
11
NC
12
NC
J2 mates with
Molex housing 43061-0012 &
Molex series 5194 crimp terminals
Notes
1. All dimensions in inches (mm). Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
2. Weight: DCM60: 0.3 lbs (136 g) approx. DCM100: 0.4 lbs (181 g) approx.
3. Cover kits available separately, order part number no. ECM40/60 COVER (4.49 x 2.52 x 1.52 (114 x 64 x 38.5)) for DCM60 or
part no. ECM100 COVER (4.96 x 3.05 x 1.52 (126 x 77.5 x 38.5)) for DCM100. Output power derates by 20% with cover fitted.
-