EEWORLDEEWORLDEEWORLD

Part Number

Search

713FM394ZW2016-CKT

Description
Military Connector Accessory,
CategoryThe connector    Connector bracket   
File Size246KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

713FM394ZW2016-CKT Overview

Military Connector Accessory,

713FM394ZW2016-CKT Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid145009799770
Reach Compliance Codenot_compliant
Rear case cable clipBAND
Connector bracket typeCONNECTOR ACCESSORY
DIN complianceNO
IEC complianceNO
MIL complianceYES
MaterialSTAINLESS STEEL
Military connector accessories nameBACKSHELL
Housing size20
Environmental Self-Locking Metal Backshell with Drop-In and
Band Termination for Series 74 Helical Convoluted Tubing
713-394
Hat Trick System
Series 74
Helical Tubing
Easy-to-install Hat Trick convoluted tubing-to-bulkhead fitting, metal
How To Order
Product
Series
Angular
Function
N
= 90°
M
= 45°
S
= Straight
B
= Additional Band
(600-052)
C
= Additional Pre-Coiled
Band (600-052-1)
(Omit for no add’l band)
Material/
Finish Sym
(Table II)
Dash
Number
(Table IV)
T
= Shrink Boot
(Table IV)
(Omit for none)
713
H
S
394 M 17 16
-
4
Basic
Number
Shell Size
(Table III)
B P K T
PTFE Coating
(Omit for none)
S
C
O-RING
TYP
A THREAD
TYP
Connector
Designator
A, F,
or
H
S
= Polysulfide
(Omit for none)
Optional Length
In 1/2" increments, sym. S straight
only. (e.g. 4=2.0". min. 2.0”)
Omit for standard length.
1.75 MAX STD LENGTH
(See P/N Development)
Internal surfaces
coated with PTFE*
Termination Area
Free Of Cadmium.
Knurl Or Ridges
Mfrs Option
Anti-decoupling
Device Typ
Add
K
for
PEEK Conduit
(Omit for Std.
Fluoropolymer Materials)
F
C
DIA B DIA TYP
TYP
S Option
Polysulfide Stripes
See Part Number
Development
.380
TYP
.65
TYP
.060
TYP
.135
TYP
Micro-band 600-057-1
for termination to Drop-In adapter
supplied with all configurations
D
Boot Groove
Typ
G
SYM S - STRAIGHT
SYM N - 90°
E
H
Conduit
I.D. Nom
Typ
J Dia
Typ
K Dia
Typ
KEY
Detail view with drop-in adapter extended
for clarity. Area around and on the keys,
conduit thread area and interfacial teeth
free of PTFE coating
SYM M - 45°
Accommodates additional Standard Band
supplied with B or C option
O-RING
Material and Finish/Notes
C Option
Additional
Pre-coiled
Band
Connector Designator A
Detail
Adapters, Hex Nuts: Table II (See P/N development)
Anti-decoupling device: Corrosion-resistant material
O-Ring - Silicone/N.A. • Band - SST/Passivate • Shrink Boot - See individual drawing.
Assembly supplied with Micro-Band (600-057-1) for shield termination onto the drop-in
adapter. Options B and C are for additional Standard Band to terminate overall shielding.
*Internal surfaces coated with PTFE in area indicated, see P/N development.
U.S. CAGE Code 06324
Rev. 1.5.2017
Printed in U.S.A.
© 2012 Glenair, Inc.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
C-34
E-Mail: sales@glenair.com
About the parallel and series resistors at OUT in the crystal oscillator circuit
Is the parallel resistor in the crystal oscillator a damping resistor? Reduce the amplitude? Connecting R in series causes the output frequency to be too high? Is there any problem with what is said a...
lx331lx Analog electronics
Single-chip microcomputer controlled xc1004 four-axis SPI motion control chip information
The single-chip microcomputer controls the xc1004 four-axis SPI motion control chip, which simplifies the project difficulty. If you need it, you can download it and take a look....
w75815895 stm32/stm8
I would like to ask a basic question: Is the discharge speed of parallel capacitors determined by the ESR of the capacitors?
[i=s]This post was last edited by snowblind123 on 2022-4-25 10:53[/i]I would like to ask a basic question. Is the discharge speed of parallel capacitors determined by the ESR of the capacitor? 100HZes...
snowblind123 Analog electronics
How to choose the appropriate inductor and its parameters? | MPS invites you to learn practical tips and win gifts by commenting!
In Buck circuit, the design of inductor is a key point, which is closely related to the efficiency, output ripple voltage and loop stability of the system. Let's discuss with MPS: how to choose the ap...
EEWORLD社区 Power technology
I need help with soldering tips. Why does flux often splash out when I add tin to my soldering iron, burning my hands?
Hey guys, why does the flux often splash out when I add tin to my soldering iron and burn my hands? Soldering Tips for Help...
Knight97538 Power technology
What are the differences between RTU and DTU?
1. Name:RTU: The full name of RTU is Remote Terminal Unit, which is responsible for monitoring and controlling field signals and industrial equipment.DTU: The full name of DTU is Data Transfer Unit. I...
蓝先生 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号