ASEMPC-156.2500MHZ-ZR-PD-T5

Description
CMOS Output Clock Oscillator,
CategoryPassive components    oscillator   
File Size4MB,6 Pages
ManufacturerAbracon
Websitehttp://www.abracon.com/index.htm
Download Datasheet Parametric View All

ASEMPC-156.2500MHZ-ZR-PD-T5 Overview

CMOS Output Clock Oscillator,

ASEMPC-156.2500MHZ-ZR-PD-T5 Parametric

Parameter NameAttribute value
Objectid7023913876
Reach Compliance Codecompliant
YTEOL6.65
Other featuresPOWER DOWN; ENABLE/DISABLE FUNCTION; TR, 13 INCH
maximum descent time2 ns
Frequency Adjustment - MechanicalNO
frequency stability25%
Installation featuresSURFACE MOUNT
Number of terminals6
Nominal operating frequency156.25 MHz
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Oscillator typeCMOS
Output load15 pF
physical size3.2mm x 2.5mm x 0.85mm
longest rise time2 ns
Maximum supply voltage3.6 V
Minimum supply voltage2.25 V
surface mountYES
maximum symmetry55/45 %
Analysis of the working principles of seven triode collector DC circuits 1
[align=left][color=rgb(34, 34, 34)][font="][size=4]The transistor collector DC circuit is the circuit between the collector and the DC working voltage terminal. This DC circuit is the circuit with the...
tiankai001 Analog electronics
A very good introduction to the ble Bluetooth protocol stack
Important things to say in advance: I would be satisfied if I could understand the data that is ultimately exposed to the air during a Bluetooth transmission, and then parse and understand it. I searc...
辛昕 RF/Wirelessly
A UART Circuit Design Based on FPGA
A UART Circuit Design Based on FPGA...
zxopenljx FPGA/CPLD
[RVB2601 Creative Application Development] Flower Watering Indicator
Flower watering indicator Author: Zhang Zezhong Flowers are loved by everyone. Many people like to grow flowers. The flowers they just bought are gorgeous and colorful, but after a few days, the flowe...
gsrnj XuanTie RISC-V Activity Zone
Understanding the alarm performance in arc fault detectors (fault arcs with 14 or more half cycles occurring within 1 second)
How to understand the alarm performance of 14 or more half-cycles of arc faults in 1s in GB14287.4 "Electrical Fire Monitoring System Part 4: Arc Fault Detector"? How to understand the alarm performan...
流萤宸殇 Test/Measurement

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号