EEWORLDEEWORLDEEWORLD

Part Number

Search

C0805T471M2RCC7411

Description
Ceramic Capacitor, Ceramic, 200V, 20% +Tol, 20% -Tol, X7R, -/+15ppm/Cel TC, 0.00047uF, 0805,
CategoryPassive components    capacitor   
File Size147KB,8 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

C0805T471M2RCC7411 Overview

Ceramic Capacitor, Ceramic, 200V, 20% +Tol, 20% -Tol, X7R, -/+15ppm/Cel TC, 0.00047uF, 0805,

C0805T471M2RCC7411 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid711107876
package instruction, 0805
Reach Compliance Codecompliant
Country Of OriginMexico
ECCN codeEAR99
YTEOL6.8
capacitance0.00047 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high0.78 mm
JESD-609 codee3
length2 mm
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Paper, 13 Inch
positive tolerance20%
Rated (DC) voltage (URdc)200 V
seriesC(SIZE)-COTS
size code0805
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
width1.2 mm
Product Bulletin
Ceramic Commercial-Off-The-Shelf Surface Mount Capacitors (COTS)
KEMET is a qualified supplier of various military and high reliability specifications. The COTS program is an extension
of KEMET's knowledge of high reliability test regimes and requirements. KEMET has for years supplied product that has
been "up-screened" by working with customer drawings and imposing the design and test requirements specified. The COTS
program will offer the same high quality and reliability components "up-screened" to the ordered test level at a lower cost to
the customer. It eliminates the need for customer specific drawings used to achieve the reliability level required for customer
applications. The tests and inspections imposed by the COTS program have been selected to provide the accelerated con-
ditioning and 100% screening to eliminate infant mortal failures from the population.
All COTS testing includes Voltage Conditioning and post electrical testing per MIL-PRF-55681, paragraph 4.8.3.1, Standard
voltage conditioning. For enhanced reliability, KEMET also provides the following test options and conformance certification.
Test Level “A”
Test Level “B”
Test Level “C”
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
Voltage
Conditioning
DWV
IR@25°C
CAP
DF
PDA 8%
C of C
PDA 8%
DPA
C of C
PDA 8%
DPA
85/85
C of C
• All COTS testing includes
Voltage Conditioning and post
electrical testing per MIL-PRF-
55681
• DPA per EIA-469
• Humidity, steady state, low
voltage (85/85) per MIL-STD
202, Method 103, condition A
• Certificate of Compliance
KEMET COTS MLCC surface mount capacitors are available in standard EIA case sizes from 0402 to 2225 and
standard capacitance values in X7R and C0G dielectrics. Voltage ratings range from 6.3V to 200V. To order the
COTS part number use a T in the 6th digit of the part number in conjunction with the desired test level A, B, or C
in the 13th digit. A Tin/Lead termination option is also available with COTS by using a L in the 14th digit of the
part number. For additional dielectrics and voltage ratings please contact the factory or local Sales personnel.
Applications
Military Products
Space Quality Products
High Reliability Electronics
F-9038B 01/06
How to measure BLE power consumption (one of the most viewed app reports)
Click to view detailsHow to measure the power consumption of BLE.pdf...
Jacktang Wireless Connectivity
Can anyone help explain the authentication process when the NB-IOT card is connected to the telecom network?
Can anyone help explain the authentication process when the NB-IOT card is connected to the telecom network?...
深圳小花 Embedded System
[Erha Image Recognition Artificial Intelligence Vision Sensor] 4. Color recognition and object recognition
Erha sensor's color recognition is still very accurate and fast. We will perform multiple color recognition this time. First, we need to set it to "learn multiple", which is the same as the setting fo...
annysky2012 Domestic Chip Exchange
[Synopsys IP Resources] How many steps are required for a successful RDC sign-off?
In last week’s article on clock domain crossing (CDC), we pointed out that CDC errors are one of the biggest challenges for ASIC design.Cross-reset domain (RDC) errors may also have catastrophic conse...
arui1999 Integrated technical exchanges
Use Burn in software to test and vibration test the hard disk and a temperature alarm appears
When the computer was tested using the burn in software, when a certain level of vibration was applied to the computer, the hard disk reported a transient temperature problem, with the highest tempera...
jhon~~ Test/Measurement
[Bing Dwen Dwen Award List] 2022 Digi-Key Innovation Design Competition
Event details: 2022 Digi-Key Innovation Design CompetitionThank you for your participation and support in this competition. The list of winners of the lovely Bing Dwen Dwen is out. Congratulations to ...
EEWORLD社区 DigiKey Technology Zone

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号