EEWORLDEEWORLDEEWORLD

Part Number

Search

2105-N3-13-60

Description
Card Edge Connector, 10 Contact(s), 2 Row(s), Female, Straight, Solder Terminal
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

2105-N3-13-60 Overview

Card Edge Connector, 10 Contact(s), 2 Row(s), Female, Straight, Solder Terminal

2105-N3-13-60 Parametric

Parameter NameAttribute value
Objectid1970362246
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.18 mm
Termination typeSOLDER
Total number of contacts10
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
TMS320C6678 ZYNQ Dual-core ARM Communication Case Development Manual - matrix_multiply Case
Table of contents 2matrix_multiply example 2.1Case Function 2.2Operation Instructions 2.3Key Code 2.3.1linux_demo code description 2.3.2freertos_demo code description 2.3.3baremetal_demo code descript...
别打牛牛 DSP and ARM Processors
Monochrome screen upgrade: How to quickly upgrade the DWIN T5UIC1 color screen
[align=left][b][color=black][font=TimesNewRomanPS-BoldMT][size=11.0pt]1. [/size][/font][/color][/b][color=black][font=宋体][size=11pt]Why upgrade to color screen? [/size][/font][/color][/align][align=le...
DWIN_IOT Industrial Control Electronics
Intelligent management tools used by power operation and maintenance personnel
Electric power operators have to operate, inspect, and perform routine maintenance every day, and test and rotate equipment regularly. If a fault occurs, they have to go to the site to check and deter...
LivingLab1 Industrial Control Electronics
[Automatic clock-in walking timing system based on face recognition] K210 MAIXBIT uses QR code recognition as user information
Debug TargetConsidering that the K210 has relatively few interactive interfaces, the user information entry method is considered to be a QR code. The ID name can be scanned once, and then the user is ...
alanlan86 DigiKey Technology Zone
Several types of Bluetooth antennas are summarized. Which one is more familiar with Bluetooth signals? Which type of Bluetooth is used for the same chip...
Several types of Bluetooth antennas are summarized. Which one is more familiar with Bluetooth signals? Which type of Bluetooth antenna will have greater transmission power and better receiving sensiti...
QWE4562009 Discrete Device
【NXP Rapid IoT Review】+2. NXP Rapid IOT APP Connection Test
[i=s]This post was last edited by weiwei4 on 2019-1-16 01:05[/i] I really don’t think the NXP Rapid IOT APP is that easy to use. First of all, as mentioned in the previous post, the App has certain co...
weiwei4 RF/Wirelessly

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号