EEWORLDEEWORLDEEWORLD

Part Number

Search

T12-222N8.5TZZ06

Description
T12-222N8.5TZZ06
CategoryPassive components    The resistor   
File Size155KB,7 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

T12-222N8.5TZZ06 Overview

T12-222N8.5TZZ06

T12-222N8.5TZZ06 Parametric

Parameter NameAttribute value
Objectid400425777
Reach Compliance Codecompliant
ECCN codeEAR99
1
CIRCUIT BREAKERS FOR EQUIPMENT
T12 Series
Thermal release
• Positively trip-free
• Reset or manual
actuation
A circuit breaker for equipment (CBE) of the T12 series is a single
pole, thermally operated device providing small size, low cost and
reliable trip-free operation on overloads and short circuits, up to the
maximum breaking capacity. It is intended primarily for protection
of motors, transformers, solenoids etc. against damage due to over-
current conditions.
The well proven mechanism is designed to open the contacts in the
event of a current flow in excess of the time/current characteristic of
the device. A bimetal strip is heated by the overcurrent and deflects,
thereby releasing the latch mechanism. The contacts will open even
if the reset button is manually held in the closed position. This is
known as the positively trip-free feature. The contacts open and
close with a snap action and the tripped state is clearly shown by the
increased projection of the reset button. After operation, the
mechanism will not latch closed until the manual reset button is fully
depressed and then released. It is impossible to ‘tease’ the contacts
by gentle pressure on the reset button.
The time which can elapse in case of an overcurrent is given by
the tripping characteristic (tripping zone). This curve is valid for a
device operating at an ambient temperature of +23°C, without
any preloading.
Available options
Flange type
Threaded neck type
Type of actuation: reset or manual ON/OFF (push/push)
Terminals:
– quick connect terminals
– screw clamp terminals
• Independent auxiliary contact (change-over contact)
• Shunt terminal
• Setting indication on the reset button indicates the position
of the contacts
Special features
Competitive pricing
Quick connect terminals
Choice of mounting styles
Positively trip-free
Not affected by shock or vibration
UL, CSA, VDE and other approvals
186
Schurter, Inc. • Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号