C3430
Typical Applications
Base Stations
FCXO
Features
Surface Mount Package
Reflow Process Compatible
Low Phase Noise
Build in PLL-Circuit
Output Frequency range
Standard frequencies
10 MHz – 700 MHz
10; 25; 26; 39.3216; 52; 56; 61.44;77.76; 104 MHz
122.88; 153.6; 155.52; 160; 184.32; 311.04 MHz
491.52; 622.08 MHz
Reference Frequency
Parameter
Input frequency
Standard input frequencies
Min
1
Typ
10
13
26
32,768
Typ
HCMOS
Max.
300
Units
MHz
MHz
MHz
MHz
MHz
Units
V
pp
kΩ
V
V
Ω
V
V
Ω
Condition
± 2 ppm
Ordering Code
X106
X136
X266
X326
Condition
IFH
HCMOS / similar sinewave
IFP
1.68
2.42
50
LVDS
-0.45
0.25
100
-0.25
0.45
LVPECL
5
Parameter
Signal
Reference Level
Reference Input Impedance
Signal
Reference Level Min
Reference Level Max
Reference Input Impedance
Signal
Reference Level Min
Reference Level Max
Reference Input Impedance
Min
0.5
2
Max.
4
PECL
1.355
2.155
IFL
LVDS
Output Frequency
Parameter
output frequency
Signal
Load
Rise and Fall time
Duty cycle
Signal
Load
Rise and Fall time
Duty cycle
Signal
Load
Rise and Fall time
Duty cycle
Min
10
Typ
HCMOS
15.0
40
PECL
50
45
LVDS
100
40
1
60
1
55
5
60
Max.
700
Units
MHz
pF
ns
%
Ω
ns
%
Ω
ns
%
Condition
Ordering Code
RFH
@ 15 pF 10 to 90 %
@ Vs/2
RFP
Vs - 2V
20 to 80 %
RFL
10 to 90 %
5
Supply voltage (Vs)
Parameter
Supply voltage [Standard]
Current consumption
Min
3.135
Typ
3.3
Max.
3.465
50
Units
VDC
mA
Condition
Ordering Code
SV033
5
steady state @ +25°C & 3.3VDC
Vectron International
·
www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2007-03-09 · page 1 of 7
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju Road,
WaiGaoQiao Free Trade Zone, Pudong,
Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax
C3430
FCXO
Additional parameters
Parameter
3
Phase Noise
Min
Typ
-95
-125
-142
-155
-160
0.7
-75
-105
-130
-140
-142
0.2
Max.
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Ps RMS
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Ps RMS
Condition
10 Hz
@ 10 MHz
100 Hz
HCMOS
1 kHz
10 kHz
100 kHz
@ 10Hz .. 100kHz
10 Hz
@ 311.04 MHz
100 Hz
PECL
1 kHz
10 kHz
100 kHz
@ 12kHz .. 20MHz
Jitter
3
Phase Noise
Jitter
Additional parameters
Parameter
VCXO Control PIN 7
Weight
Processing & Packing
Operating temperature range
Operable temperature range
Storage temperature range
Min
0.5
Max.
2.5
9
Handling & processing note
+70
+85
+125
Typ
Units
V
g
°C
°C
Condition
-20
-30
-55
Vectron International
·
www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2007-03-09 · page 2 of 7
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju Road,
WaiGaoQiao Free Trade Zone, Pudong,
Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax
C3430
Type G233
Input : Single ended (HCMOS or Sinewave)
Output : 1x HCMOS or PECL or LVDS
Package Codes :
Code
A1
Height “H”
5.9
Pin Length “L”
NA
FCXO
Type G273
Input : Complementary (PECL or LVDS)
Output : 1x PECL or LVDS
Code
B1
Height “H”
5.9
Pin Length “L”
NA
Dimensions : mm
Dimensions : mm
Pin Connections
1
VCXO Control
Description
Test output
of the control voltage for the
VCXO
Only for modul test or observance
Test output
signal for PLL lock detected.
High signal
à
PLL in lock
Low signal
à
PLL out of lock
Only for modul test or observance
1
Pin Connections
VCXO Control
Description
Test output
of the control voltage for the
VCXO
Only for modul test or observance
Test output
signal for PLL lock detected.
High signal
à
PLL in lock
Low signal
à
PLL out of lock
Only for modul test or observance
2
Lock Detector
Output
2
Lock Detector Output
6;7 GND
8
9
RF-OUT
RF-Out
complementary /
(GND: Single
ended input only)
Ground connection. Keep traces physically
short and connect immediately to ground plane
for best performance
RF syncronised output.
RF syncronised output.
Ground connection: Single Ended Input only
3
N.C.
5
GND
6;7 GND
8
9
RF-OUT
RF-Out
complementary
Ground connection. Keep traces physically
short and connect immediately to ground
plane for best performance
RF syncronised output.
RF syncronised output.
10
12
13
14
Ref. Frequency in
Vs
High stable input frequency for syncronisation
Power supply pin
13
14
GND
Ref. Frequency
Complementary in
Ref. Frequency in
Vs
High stable complementary input frequency
for syncronisation
High stable input frequency for
syncronisation
Power supply pin
v.2007-03-09 · page 3 of 7
Vectron International
·
www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju Road,
WaiGaoQiao Free Trade Zone, Pudong,
Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax
C3430
Type G273
Input : Single ended (HCMOS or Sinewave)
Output : 2x PECL or LVDS
Package Codes :
Code
C1
Height “H”
5.9
Pin Length “L”
NA
FCXO
Type G267
Input : Single ended (HCMOS or Sinewave)
Output : 4x HCMOS (same frequency)
Code
D1
Height “H”
5.9
Pin Length “L”
NA
Dimensions : mm
Dimensions : mm
Pin Connections
1
VCXO Control
Description
Test output
of the control voltage for the
VCXO
Only for modul test or observance
Test output
signal for PLL lock detected.
High signal
à
PLL in lock
Low signal
à
PLL out of lock
Only for modul test or observance
1
Pin Connections
VCXO Control
Description
Test output
of the control voltage for the
VCXO
Only for modul test or observance
Test output
signal for PLL lock detected.
High signal
à
PLL in lock
Low signal
à
PLL out of lock
Only for modul test or observance
4 independent RF syncronised outputs
Ground connection. Keep traces physically
short and connect immediately to ground
plane for best performance
4 independent RF syncronised outputs
4 independent RF syncronised outputs
4 independent RF syncronised outputs
High stable input frequency for
syncronisation
Power supply pin
2
Lock Detector
Output
2
Lock Detector Output
3
5
6
N.C.
GND
RF-OUT 1
RF output frequency 1
5
6
RF-OUT 1
GND
7
8
9
10
12
13
14
Compl. RF-OUT 1
RF-OUT 2
Compl. RF-OUT 2
GND
N.C.
Ref. Frequency in
Vs
Complimentary RF output frequency 1
RF output frequency 2
Complimentary RF output frequency 2
7
8
9
10
13
14
RF-OUT 2
RF-OUT 3
GND
RF-OUT 4
Ref. Frequency in
Vs
High stable input frequency for
syncronisation
Power supply pin
Vectron International
·
www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2007-03-09 · page 4 of 7
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju Road,
WaiGaoQiao Free Trade Zone, Pudong,
Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax
C3430
FCXO
Marking
C3430A1-xxxx
Frequency
* VI AYYWW
Absolute Maximum Ratings
Parameter
Supply voltage (Vs)
Maximum output load @ CMOS
Min
Typ
Max.
6.0
40
Units
V
pF
Condition
Typical Phase Noise and Jitter
(10 MHz; HCMOS output)
(311,04 MHz; PECL output)
Frequency range [Hz]
10Hz to 100kHz
Jitter [ps rms]
0.708ps
Frequency range [Hz]
12kHz to 20MHz
Jitter [ps rms]
0.168ps
Block Diagramm
VS
VCXO
Control
VS
Reference
Frequency
PLL
Circuit
Loop
Filter
VCXO
0
5
1
VS
4
8
VCXO
VS
5
VCXO
8
4
0
1
0
Lock
Detector
Vectron International
·
www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2007-03-09 · page 5 of 7
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju Road,
WaiGaoQiao Free Trade Zone, Pudong,
Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax