U.I. Lapp
GmbH
PRODUCT INFORMATION
MULTI-STANDARD SC 2.1
29.11.2013
USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands
For use in the most important global markets
Reduction in technical documentation
Easier storage; increases the cost-effectiveness of the production process
Works with "Conductor end sleeves XL, insulated"
Oil-resistant
Application range
Factory wiring
Field wiring
Internal wiring of devices
Control cabinet wiring
Design
Fine-wire strand made of tinned-copper wires
Special PVC-based core insulation
No outer sheath, no nylon jacket, no outer wrapping
Norm references / Approvals
Multi-standard cables have conductor strands with nominal sizes in mm² or AWG/kcmil. The master size is mentioned in the
table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related
secondary size the cross-section of the conductor mostly works out to be greater than thespecified nominal value.
Cable type certifications: <HAR> H07V-K acc. EN 50525-2-31, UL AWM style 1015 (by UL acc. UL standard UL 758, U.I. Lapp
GmbH's UL AWM file number: E63634), (UL) MTW (by UL acc. UL standard UL 1063, U.I. Lapp GmbH's (UL) MTW file number:
E198296), CSA TEW (by CSA acc. CSA standard CSA C22.2 No. 127, CSA class 5835-01)
Product features
Flame-retardant according IEC 60332-1-2
Flame-retardant according to UL VW1/CSA FT1
Oil-resistant
Remark
Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon
request.
Copper price basis: EUR 150/100kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related
surcharges.
Packaging size: Coil ≤ 30 kg, otherwise drum
Photographs are not to scale and do not represent detailed images of the respective products.
Non-harmonised, nominal cross-sections: 0.5 mm², 0.75 mm², 1 mm², 16 mm²
*for conventional use, **for careful bending; "OD" = outer diameter
The outer diameters stated in the part number table are maximum values.
Product Management
Document: LAPP_PRO108167EN.pdf
1/9
©2012 Lapp Group - Technical changes reserved
PN 0486/0_03.0
Photographs are not to scale and do not represent detailed images of the respective products.
U.I. Lapp
GmbH
PRODUCT INFORMATION
MULTI-STANDARD SC 2.1
29.11.2013
Technical Data
Classification:
ETIM 5.0 Class-ID: EC000993
ETIM 5.0 Class-Description: Single core cable
> 10 GOhm x cm
Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
OD ≤ 8 mm: 4 x OD*/2 x OD**
8 < OD ≤ 12 mm: 5 x OD*/3 x OD**
OD > 12 mm: 6 x OD*/4 x OD**
HAR / IEC: U₀/U: 450/750 V
UL (AWM): U: 600 V
UL (MTW): U: 600 V
CSA (TEW): U: 600 V
Specific insulation resistance:
Conductor stranding:
Minimum bending radius:
Nominal voltage:
Test voltage:
Temperature range:
2500 V
Fixed installation:
HAR/IEC: -40°C to +70°C
UL (AWM): -40°C to +105°C
UL (MTW): -40°C to +90°C
CSA (TEW): -40°C to +105°C
Product Management
Document: LAPP_PRO108167EN.pdf
2/9
©2012 Lapp Group - Technical changes reserved
PN 0486/0_03.0
Photographs are not to scale and do not represent detailed images of the respective products.