Features ....................................................................................................................................................................................... 1
Ordering Information .................................................................................................................................................................... 2
Revision History ......................................................................................................................................................................... 15
Rev 0.5
Page 2 of 18
www.sitime.com
SiT9347
220 MHz to 725 MHz Endura™ Series Ultra-low Jitter Differential Oscillator
Electrical Characteristics
All Min and Max limits in the Electrical Characteristics tables are specified over temperature and rated operating voltage
with standard output termination shown in the termination diagrams. Typical values are at 25°C at nominal supply voltage.
Table 2. Electrical Characteristics – Common to LVPECL, LVDS and HCSL
Parameter
Output Frequency Range
Frequency Stability
Symbol
f
F_stab
Min.
220.000001
-10
Typ.
–
–
Max.
725
+10
Unit
MHz
ppm
Condition
Accurate to 6 decimal places
Inclusive of initial tolerance, operating temperature, rated power
supply voltage and load variations.
Contact SiTime
for ±10 ppm.
Inclusive of initial tolerance, operating temperature, rated power
supply voltage and load variations
Frequency Range
Frequency Stability
-20
-25
-50
First Year Aging
10 Year Aging
20 Year Aging
F_1y
F_10y
F_20y
-0.7
-1.4
-1.6
–
–
–
±0.4
±0.8
±1.0
+20
+25
+50
+0.7
+1.4
+1.6
ppm
ppm
ppm
ppm
ppm
ppm
At 85°C
At 85°C
At 85°C
Temperature Range
Operating Temperature Range
T_use
-20
-40
-40
-40
Acceleration (g) sensitivity,
Gamma Vector
Supply Voltage
F_g
–
–
–
–
+70
+85
+95
+105
°C
°C
°C
°C
Extended Industrial
Low sensitivity grade; total gamma over 3 axes; 15 Hz to 2 kHz; MIL-
PRF-55310, computed per section 4.8.18.3.1
Extended Commercial
Industrial
Rugged Characteristics
–
–
0.1
ppb/g
Supply Voltage
Vdd
2.97
2.70
2.52
2.25
Input Voltage High
Input Voltage Low
Input Pull-up Impedance
Duty Cycle
Startup Time
OE Enable/Disable Time
VIH
VIL
Z_in
DC
T_start
T_oe
70%
–
–
45
–
–
3.30
3.00
2.80
2.50
–
–
100
–
–
–
3.63
3.30
3.08
2.75
–
30%
-
55
3.0
3.8
V
V
V
V
Vdd
Vdd
kΩ
%
ms
µs
Measured from the time Vdd reaches its rated minimum value.
f = 322.265625 MHz. Measured from the time OE pin reaches rated
VIH and VIL to the time clock pins reach 90% of swing and high-Z.
See
Figure 8
and
Figure 9
Pin 1, OE
Pin 1, OE
Pin 1, OE logic high or logic low
Input Characteristics
Output Characteristics
Startup and OE Timing
Rev 0.5
Page 2 of 18
www.sitime.com
SiT9347
220 MHz to 725 MHz Endura™ Series Ultra-low Jitter Differential Oscillator
Table 3. Electrical Characteristics – LVPECL Specific
Parameter
Current Consumption
OE Disable Supply Current
Output Disable Leakage Current
Maximum Output Current
Output High Voltage
Output Low Voltage
Output Differential Voltage Swing
Rise/Fall Time
RMS Period Jitter
[3]
Symbol
Idd
I_OE
I_leak
I_driver
VOH
VOL
V_Swing
Tr, Tf
T_jitt
T_phj
Min.
–
–
–
–
Vdd-1.15
Vdd-2.0
1.2
–
–
–
Typ.
–
–
0.15
–
–
–
1.6
225
1.0
0.220
Max.
94
63
–
33
Vdd-0.7
Vdd-1.5
2.0
330
1.6
0.270
Unit
mA
mA
A
mA
V
V
V
ps
Ps
Ps
Condition
Excluding Load Termination Current, Vdd = 3.3V or 2.5V
OE = Low
OE = Low
Maximum average current drawn from OUT+ or OUT-
See
Figure 4
See
Figure 4
See
Figure 5
20% to 80%, see
Figure 5
f = 100, 156.25 or 212.5 MHz, Vdd = 3.3V or 2.5V
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs. Temperature ranges -20 to 70ºC and
-40 to 85ºC.
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs. Temperature ranges -40 to 95ºC and
-40 to 105ºC
f = 322.265625 MHz, IEEE802.3-2005 10GbE jitter mask
integration bandwidth = 1.875 MHz to 20 MHz, Includes spurs, all
Vdd levels
f = 100, 156.25 or 212.5 MHz, Vdd = 3.3V or 2.5V
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs. Temperature ranges -20 to 70ºC and
-40 to 85ºC.
f = 322.265625 MHz, Integration bandwidth = 12 kHz to 20 MHz,
all Vdd levels, includes spurs. Temperature ranges -40 to 95ºC and
-40 to 105ºC
f = 322.265625 MHz, IEEE802.3-2005 10GbE jitter mask
integration bandwidth = 1.875 MHz to 20 MHz, Includes spurs, all
A friend's electronics factory went bankrupt. Here are brand new electrical panel PCBs, each packaged separately.There are TM1621 display driver chip, CA724048 voice processing chip, NXP PCF8563T cloc...
[i=s]This post was last edited by w562601331 on 2020-5-4 21:51[/i]1. ST has placed some sample projects in GitHub to implement simple functions:
Add these projects to the configured projects to implem...
3. OLED displays temperature and humidityIn the previous post, the temperature and humidity sensor DHT11 was tested, and the temperature and temperature data were printed out through the serial port o...
I am sorry to trouble you all again.
As shown in the figure, the left side is the USB-B interface, and a TVS protection device in a SOT23-6 package is added. Now the lengths of the two USB cables are ...
Position: Electronic Engineer
Work Location: Dongguan
Salary: 5k-8kJob Responsibilities:1. Operate the equipment to complete ACF bonding and combine FPC and substrate2. Operate the analog front-end ci...
Network services obtained through Sonoff WiFi Smart Socket.https://github.com/jedie/micropython-sonoff-webswitchFunctionWeb interface
Schedule multiple timers
OTA updates (directories are not currentl...
Brief introduction of TH2683A insulation resistance tester: TH2683A insulation resistance tester is a measuring instrument with touch function and color LCD that can quickly measure the insulation pr...[Details]
Recently, Netcom learned from the official that Toyota Motor Corporation-funded United Fuel Cell System Research and Development (Beijing) Co., Ltd. (hereinafter referred to as FCRD) and Huafeng Fuel...[Details]
STM32 PWM wave dynamic frequency modulation and duty cycle adjustment Take TIM3_CH1 as an example (1) Working principle of timer The time base unit of the timer consists of three parts: ① automatic...[Details]
Problem: I need to determine the change in resistance of a low resistance sensor, and my plan was to simply apply a known voltage across the thin wire sensor leads and measure the current. Then using...[Details]
In the industrial field, low-frequency digital phase meters are often used to accurately measure the phase difference between two signals. For example, they are widely used in power systems, frequenc...[Details]
Last night (8), Huawei held an online spring new product launch conference in China, launching the Huawei P40 series and other new products. Today (9), Huawei Consumer Business CEO Richard Yu accepte...[Details]
On November 7, the 2020 Tianyi Smart Ecosystem Expo and the 12th Tianyi Smart Ecosystem Industry Summit Forum were held in Guangzhou. At the conference, China Telecom officially announced that 5G SA ...[Details]
In recent years, the global automotive industry has entered an era of great changes.
Intelligent networking
has accelerated the reshaping of the new industrial landscape. Vehicle-road-cloud...[Details]
#include //There are only SPWM-related programs in the program now, and other programs have been deleted
#include
#pragma interrupt_handler T0:17 //Timer 0 overflow interrupt vector
unsigned ...[Details]
The Bluetooth network topology configuration method invented by Jier Technology can automatically transfer the networking parameters and phase synchronization relationships used by the original commu...[Details]
Let's talk about video signals. We know that oscilloscopes can be divided into analog and digital oscilloscopes, and video signals can also be divided into analog and digital. Today we will share how...[Details]
In order to solve the problem of DC inverter AC, effectively utilize energy, and make the power supply output maximum power, a high-performance maximum power tracking inverter based on IR2101 is desi...[Details]
Introduction: This paper takes ATmega8 microcontroller as the core and designs a distributed, modular electric vehicle battery management system that communicates via LIN bus and has intelligent char...[Details]
Traditional planar or trench MOSFET switches with rise/fall times of 30ns to 60ns are gradually being replaced by power switches such as superjunction MOSFETs with switching times of less than 5ns. T...[Details]
Recently, the geotechnical survey project of the Hebei Chicheng Gravity Energy Storage Pilot Demonstration Project undertaken by the 517th Team of the Tianjin North China Geological Survey Bureau was ...[Details]