IHB60TC
60 Watt Triple Output Half Brick DC/DC Converter
RoHS Compliant
18 - 40 & 33 - 75V Input
Range
Each Channel Independently
Current Limited
High Efficiency: 87% Typical
1500V
DC
Isolation Between
Input and Output
Operation to 100°C Baseplate
Temperature
50mS Transient Recovery,
0-90% Load Step
Primary & Secondary Remote
On/Off
IHB60TC48 Series Approved to
UL/CUL 1950, EN60950
The IHB60TC series triple output standard half brick modules are designed for
today’s demanding industrial applications. Available in two wide range inputs, these
isolated converters offer many features in the standard models. With a complement
of safety agency approvals and low noise operations, the converters respond ex-
tremely fast to change in load conditions. Inherent in the design are very well-con-
trolled output voltages and minimal need for minimum loading on main (V1) output.
PRODUCT SELECTION CHART
MODEL
IHB60T240312C
IHB60T240315C
IHB60T240512C
IHB60T240515C
IHB60T480312C
IHB60T480315C
IHB60T480512C
IHB60T480515C
INPUT
VOLTAGE
(V
DC
)
24 (18-40)
24 (18-40)
24 (18-40)
24 (18-40)
48 (33-75)
48 (33-75)
48 (33-75)
48 (33-75)
V1 (±)
3.3
3.3
5.1
5.0
3.3
3.3
5.1
5.0
RATED V
OUT
(V
DC
)
V2 (±)
12
15
12
15
12
15
12
15
V3 (±)
12
15
12
15
12
15
12
15
V1(±)
18
18
12
12
18
18
12
12
RATED MAXIMUM I
OUT
(A)
V2(±)
V3(±)
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
ABSOLUTE MAXIMUM
RATINGS
Output Short-Circuit Duration Continuous
Baseplate Temperature
Storage Temperature
Input to Output Isolation
+100°C
+125°C
1500 V
DC
EFFICIENCY vs TEMPERATURE
T
CASE
= +40°C, nominal input voltage, nominal load, recommended external
components applied, unless otherwise specified.*
Change in Efficiency (%)
ISO9001
CERTIFIED
Case Temperature (°C)
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MDC_IHB60TC.B01
Page 1 of 4
IHB60TC
60 Watt Triple Output Half Brick DC/DC Converter
SPECIFICATIONS, ALL MODELS
Specifications are at T
CASE
= +40°C nominal input voltage unless otherwise specified.
PARAMETER
CONDITIONS
MIN
18
33
Peak - Peak
DC to 1KHz
Output Power = 60W
V
IN
= 16V
V
IN
= 30V
P
OUT
= 0, V
IN, Min
<V
IN
<V
IN, Max
50
Voltage Range
IHB60T24XXC Series
IHB60T48XXC Series
Reflected Ripple Current
Input Ripple Rejection
Maximum Input Current
IHB60T24XXC Series
IHB60T48XXC Series
No Load Power Dissipation
Inrush Charge
IHB60TC24XX Series
IHB60TC48XX Series
Quiescent Operating Current
Primary On/Off Disabled
Secondary On/Off Disabled
TYP
24
48
60
MAX
40
75
220
UNITS
V
DC
V
DC
mA
dB
A
A
W
mC
mC
mA
mA
INPUT
6
3
6
0.29
0.165
7.5
15
10
25
PARAMETER
ISOLATION
Input to Output
Input to Baseplate
Channel to Channel
Resistance, Input - Output
Capacitance, Input - Output
Leakage Current
GENERAL
Set Point Accuracy
Turn-on Time
Remote On/Off Control Inputs
Primary
Sink Current-Logic Low
Vlow
Vhigh
Secondary
Sink Current-Logic Low
Vlow
Vhigh
External Synchronization Input
Frequency
Pulse Width
Source Impedence
Input High Voltage
Input Low Voltage
Input Impedance
Switching Frequency
Weight
TEMPERATURE
Operation/Specification
Storage
Shutdown
Thermal Inpedance
CONDITIONS
Peak Test
Any Channel to Any Channel
MIN
1500
1500
500
10
TYP
MAX
UNITS
V
DC
V
DC
V
DC
MΩ
pF
μA,
rms
2000
V
ISO
= 240V
AC
, 60Hz
V
IN
= Nominal, 50% Load
Within 1% of Nominal V
OUT
Open Collector/Drain
V
IN
= V
MAX
180
1
5
3.5
%
mSec
GENERAL
7
0.8
Open Collector
100
0.4
Open Collector
440
150
4
0
470
470
480
520
320
47
5
1
490
3 (85)
+100
+125
+115
8.2
mA
V
Open Collector/Drain
μA
V
KHz
nSec
Ω
V
V
Ω
KHz
oz (g)
°C
°C
°C
°C/W
Case Temperature
-40
-55
+100
Case to Ambient
PARAMETER
CONDITIONS
Total Combined O/P Power =
60 Watts Max.
I
O Nom
V1
Min
Nom
30
3.3
9
100
.02
Max
60
18
200
3.80
.05
1.0
1.0
25
250
50
5.0
0
V2
Min Nom
15
12.2
1.25
150
.02
Max
30
Min
V3
Nom
15
12.2
1.25
150
Max
30
2.5
250
.05
UNITS
W
V
A
mV
V
%/°C
%
%
A
A
mV
μSec
V
%
IHB60TX0312C** OUTPUT
Output Power
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
0.5
DC to 20MHz
*
*
V
IN, Min
≤V
IN
≤V
IN, Max
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT
,
Nom
I
OUT1
=9A, (I
OUT2
+I
OUT3
)=2.5A
F.L. V
IN
=Nominal
3.15
2.5
0
250
Dependent on V1
.05
.02
0.05
0.50
23
19
150
35
4.2
85
86
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
*
See Application Notes available on the web at www.cd4power.com
**
X = Either 24 or 48
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MDC_IHB60TC.B01
Page 2 of 4
IHB60TC
60 Watt Triple Output Half Brick DC/DC Converter
SPECIFICATIONS, ALL MODELS
Specifications are at T
CASE
= +40°C nominal input voltage unless otherwise specified.
PARAMETER
Output Power
CONDITIONS
Total Combined O/P Power =
60 Watts Max.
I
O Nom
V1
Min
Nom
30
3.3
9
100
Max
60
18
200
3.80
.05
1.0
1.0
25
250
50
5.0
0
Min
V2
Nom
Max
Min
15
30
15.85
1
2
0
125
250
Dependent on V1
.02
.05
V3
Nom
15
15.85
1
125
.02
Max
30
2
250
.05
UNITS
W
V
A
mV
V
%/°C
%
%
A
A
mV
μSec
V
%
IHB60TX0315C** OUTPUT
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
0.5
DC to 20MHz
*
See Application Notes
*
Line Regulation
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT, Nom
I
OUT1
=9A, (I
OUT2
+I
OUT3
)=2A
F.L. V
IN
=Nominal
4.2
85
3.15
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
.02
V
IN, Min
≤V
IN
≤V
IN, Max
0.05
0.50
23
19
150
35
86
1.0
2.0
1.0
2.0
See Regulation Curves See Regulation Curves
4.0
4.0
3.2
4.0
3.2
4.0
PARAMETER
Output Power
CONDITIONS
Total Combind O/P Power =
60 Watts Max
I
O Nom
V1
Min
Nom
30
5.1
6.0
125
.02
Max
60
12
200
5.50
.05
0.10
1.0
16
300
50
6.8
0
V2
Min Nom
15
12
1.25
150
Max
30
Min
V3
Nom
15
12
1.25
150
.02
Max
30
2.5
250
.05
UNITS
W
V
A
mV
V
%/°C
%
%
A
A
mV
μSec
V
%
IHB60TX0512C** OUTPUT
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
0.5
DC to 20MHz
*
*
V
IN, Min
≤V
IN
≤V
IN, Max
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT, Nom
I
OUT1
=6A, (I
OUT2
+I
OUT3
)=2.5A
F.L. V
IN
=Nominal
4.75
2.5
0
250
Dependent on V1
.02
.05
0.05
0.50
16
12.6
200
35
6.0
86
87
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
PARAMETER
Output Power
CONDITIONS
Total Combined O/P Power =
60 Watts Max
I
O Nom
V1
Min
Nom
30
5.0
6
100
.02
Max
60
12
200
5.50
.05
0.10
1.0
16
300
50
6.8
0
V2
Min Nom
15
15.3
1
125
Max
30
Min
V3
Nom
15
15.3
1
125
.02
Max
30
2
250
.05
UNITS
W
V
A
mV
V
%/°C
%
%
A
A
mV
μSec
V
%
IHB60TX0515C** OUTPUT
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
0.5
DC to 20MHz
*
*
V
IN, Min
≤V
IN
≤V
IN, Max
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT, Nom
I
OUT1
=6A, (I
OUT2
+I
OUT3
)=2A
F.L. V
IN
=Nominal
4.60
2
0
250
Dependent on V1
.02
.05
0.05
0.50
16
12.6
200
35
6.0
86
87
1.0
2.0
See Regulation Curves
4.0
3.2
4.0
1.0
2.0
See Regulation Curves
4.0
3.2
4.0
*
See Application Notes available on the web at www.cd4power.com
**
X = Either 24 or 48
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MDC_IHB60TC.B01
Page 3 of 4
IHB60TC
60 Watt Triple Output Half Brick DC/DC Converter
MECHANICAL
SIDE
VIEW
PIN SIDE
DOWN
PIN CONNECTIONS
1
2
3
4
5
6
PRIMARY ON/OFF
-V
IN
+V
IN
SYNC IN
-V2
+V2
TRIM
+V1
-V1
SECONDARY ON/OFF
+V3
-V3
PIN SIDE UP
7
8
9
10
11
12
NOTES:
All dimensions are in inches (millimeters).
PIN PLACEMENT TOLERANCE: ± 0.005"
MECHANICAL TOLERANCE: ± 0.015"
Marked with: specific model ordered, date code, job code.
MATERIAL: Units are encapsulated in a low thermal resistance mold-
ing compound which has excellent chemical resistance, wide operating
temperature range, and good electrical properties under high humidity
environments. The encapsulant and outer shell of the unit have
UL94V-0 ratings. Lead material is matte tin 100 microinches min., over
nickel, 40-80 microinches.
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected
to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this
time and temperature range, the integrity of the device’s plastic body will not be compromised and
internal temperatures within the converter will not exceed 175°C. Care should be taken to control
manual soldering limits identical to that of wave soldering.
USA:
UK:
France:
Japan:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
Website: www.murata-ps.jp
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Canada:
Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com
ISO 9001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
Germany:
München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
07/17/08
China:
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MDC_IHB60TC.B01
Page 4 of 4