AAD160
160 Watts output power
Power Factor Correction
Parallel/Redundant Operation
Up to 88% Efficiency
Electrical Specifications
Input Voltage:
Input Current:
Inrush Current:
Power Factor:
Harmonic Distortion:
EMI Filtering:
Input Protection:
Output Power:
Line Regulation:
Load Regulation:
PARD:
Hold-up Time:
Turn-on Delay:
Output Polarity:
Minimum Load:
Transient Response:
90-264 VAC, 47-63 Hz
<2A RMS @ 115 VAC @ full load
<1A RMS @ 230 VAC @ full load
<35A, pk @ 132 VAC @ cold start
<75A, pk @ 264 VAC @ cold start
>0.98 @ full load @ 115/230VAC input
Meets EN61000-3-2
Meets CISPR 11 and 22 and FCC Part 15
Class B (conducted)
Internal AC line fuse; 250 VAC, 4.0A
Model
Miniature Switch Mode Power Supply
H.A.L.T.
TESTED
Highly
Accelerated
Life
Testing
Output Rise Time:
Remote Sense:
AC Power Fail:
<100 ms (10% to 90%)
Standard on V1 and V2
Up to 400mV of cable drop
TTL
LOW
logic “0” at least 5 ms before DC
output drops 5% (without signal jitter).
<10mA sink current for Power Fail "0".
<1mA source current for Power Fail "1".
<5% overshoot with remote sense at output
terminals
Load currents of V1 and V2 for similar units
can be shared @ <±5% of total load
Factory set, 125% ±5% on V1 and V2
cycle AC to reset
All outputs are auto recovery
Reverse current up to rated outputs
Standard operation interrupt (hiccup mode)
Up to 88%
MIL-STD-HDBK 217E
>200,000 hours @ 25°C
Highly Accelerated Life Testing
160W with 20CFM air; 80W Convection
cooled (consult factory for current ratings)
± 0.3%
± 1% for V1 and V2
± 7% for V3; ± 5% for V4
Greater of 1% or 50mV
20MHz bandwidth
>20 ms @ full load
<2 seconds
See Voltage Chart
10% for V1 and V2
5% for V3 and V4
Greater of 150mV or 3% for 25%
load change @ 1A/μs (V1 and V2)
V1
Voltages
(Volts)
V1
Currents
(Amps)
V2
Voltages
(Volts)
Overshoot/Undershoot:
Current Share (option):
Overvoltage Protect:
Short Circuit Protection:
Reverse Voltage:
Case Power Protection:
Efficiency:
MTBF:
Available Voltage Outputs*
Voltage
Codes
V2
Currents
(Amps)
V3
Voltages
(Volts)
V3
Currents
(Amps)
V4
Voltages
(Volts)
**
V4
Currents
(Amps)
-1
-2
-3
-4
-5
-6
-7
-8
-9
+1.8
+3.3
+5
+12
+15
16
16
16
6
5
+1.8
+3.3
+5
+12
+15
+24
+28
+36
+48
14
14
14
6
5
3
2.5
2
1.5
+1.8
+3.3
+5
+12
+15
+24
+28
+36
+48
3
3
3
3
2.5
1.75
1.5
1.5
1
-1.8
-3.3
-5
-12
-15
-24
-28
-36
-48
2
2
2
2
2
1.5
1
1
1
* Consult factory for other voltages and OEM quantities.
**
Standard Polarity for V4 is negative (-). V4 is available with positive polarity as a Tailored or Custom model.
Note: Standard models are
3244, 3255, 3264, 3404 and 3464
-
VOLTAGE CODE -
OPTION CODES
(See back)
-
V1 V2 V3 V4
-
AAD160
-
X X X X
-
ABC....
Example: Model Number AAD160-3244-AM = 160W Power Factor Corrected, (V1) +5V @ 16A, (V2) +3.3V @ 14A, (V3) +12V @
3A and (V4) -12V @ 2A with Current Sharing and Metric Mounting.
SEE
3rd page for
AAD160 CODE TABLE AND AVAILABLE OPTIONS.
PART # STRUCTURE:
MODEL
AAD160
Options
(code)
Safety Compliance
IEC / EN / UL / CSA
60950-1
CE declaration to Low Voltage Directive 2006/95/EC and
RoHS Directive 2011/65/EU
#6-32 PEM Nut (Standard)
Current Sharing (A)
PF Invert (B)
Thru-Hole Mounting (C)
Metric Mounting (M)
PF Open Collector (O)
Input and Options with Gold Pins (G)
Molex Output Connector with Gold Pins (J)
Molex Connectors with Standard Pins (K)
Model
Physical Specifications
Dimensions: (HxWxL)
Operating Temp:
Relative Humidity:
Storage:
Altitude:
1.25" x 3.14" x 5"
0 to 50°C; rated power to 50°C
with 20CFM air
5% to 90%, non-condensing
-50 to 85°C/20-90% RH
6561
40,000' storage
Surge & ESD Test Levels
EN61000-4-5 Level 3
EN61000-4-2 Level 2
EN61000-3-2
EN61000-4-2 Level 3 (Air Only)
EN61000-4-4 Level 3
EN61000-4-11
Meets Class B conducted limits per
CISPR 11/22
and 47 CFR 15 subpt
B
© Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice.
Item 40618 Rev A
TAMURA CORPORATION OF AMERICA
1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951
(951) 699-1270 / Fax: (951) 676-9482
(800) 472-6624
www.tamuracorp.com
FM 32227
PRODUCT CODE TABLE
AAD160 Series Part Number Code Table
Standard
AAD160-VWXU-Y
1…
Y
n
Tailored
AAD160-60ZZZ
Custom
AAD160-61ZZZ
Rated Voltages and Currents
(1)
Voltage
Codes
1
2
3
4
5
6
7
8
9
0
“V” Output
(V1)
Volts Amps
+1.8
+3.3
+5
+12
+15
16
16
16
6
5
“W” Output
(V2)
Volts Amps
+1.8
+3.3
+5
+12
+15
+24
+28
+36
+48
14
14
14
6
5
3
2.5
2
1.5
“X” Output
(V3)
Volts Amps
+1.8
+3.3
+5
+12
+15
+24
+28
+36
+48
3
3
3
3
2.5
1.75
1.5
1.5
1
(2) (3)
StandardOptions
“Y” Codes
A = Current Share
B = PF Invert
C = Thru-Hole Mounting*
G = Input and Option
Connectors with Gold Pins
J = Molex Output Connector
with Gold Pins**
K = Molex Output Connector
with Standard Pins**
M = Metric Pemnut Mounting*
O = PF Open Collector
* Pemnut chassis mounting is
standard
**7A MAX current for V1, V2
“U” Output
(V4)
Volts Amps
-1.8
-3.3
-5
-12
-15
-24
-28
-36
-48
2
2
2
2
2
1.5
1
1
1
Not Available
Not Available
Not Available
Not Available
Not Used
Not Used
Not Used
Not Used
Tailored Models
(No Safety Impact)
--------------------------
60ZZZ, where ZZZ = Factory
Assigned Number.
Harnesses,special test data or
other modifications made to a
standard model
.
Custom Models
(Safety Evaluation and/or
Review Required )
--------------------------
61ZZZ, where ZZZ = Factory
Assigned Number.
.
Notes:
1. Polarities are with respect to a common return.
2. V4 is available with positive (+) polarity as Tailored or Custom Model.
3. V4 is slaved to V1. V3 is slaved to V2.
Restrictions:
1. For V2 > +15V, V3 must be +5V to +15V or Not Used.
2. Voltage differential between V1 and V4 may not exceed 60Vrms
(S.E.L.V.).
3. Current Share is available for 1.8V, 3.3V, 5V and 12V V1 and V2
only. V4 and V3 (respectively) must also be 28V or less.
1
39759 Rev. B
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Tamura
:
AAD160-3464-A AAD160-3244-A AAD160-3255-A AAD160-3404-A AAD160-3264-A