Latching Relay
MMK
CSM_MMK_DS_E_2_1
Mechanically Latching Relays Based on the
MM Power Relay
• Low power consumption due to mechanical latch for economic
operation.
• Relays with mixed coil specifications can be produced (e.g., AC
set coil and DC reset coil).
• Operational response fast enough to enable pulse signal power
applications.
• Ambient operating temperature: –10°C to 55°C.
Refer to
Safety Precautions for All Relays.
Ordering Information
Type
Contact form
Open structure
Solder terminals
Standard
DPDT
3PDT
4PDT
DPDT+DPST-NO
DC-switching
DPDT
3PDT
4PDT
DPDT+DPST-NO
Conforming to auxiliary power
DPDT+DPST-NO
relay specifications
MM2K
MM3K
MM4K
---
MM2XK
MM3XK
MM4XK
---
---
Screw terminals
MM2KB
MM3KB
MM4KB
---
MM2XKB
MM3XKB
MM4XKB
---
---
Cased
Plug-in (octal pins)
terminals
MM2KP
MM3KP
---
MM4KP
MM2XKP
MM3XKP
---
MM4XKP
MM4KP-JD
MM4XKP-JD
Models Conforming to Auxiliary Power Relay Specifications
The MM4KP-JD and MM4XKP-JD satisfy the ratings of auxiliary relays provided in JEC-2500 (1987) standards for power protective relays specified
by the Japan Electromechanical Commission. Furthermore, the MM4KP-JD and MM4XKP-JD satisfy the ratings of multi-contact relays provided
in JEC-174D (1979) standards for power auxiliary relays.
These models work at operation level A specified by JEC-174D (1979) standards and the hot start of the relays is possible after the coils radiate
heat.
In accordance with JEC-2500 (1987) standards, the coil of each model withstands a 130% DC load or 115% AC load.
Note:
When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.
Example: MM2K, 6 VAC
Rated coil voltage
■
Available Models
Open Coils (with Solder Terminals)
Type
Standard
Contact form
DPDT
3P3T
DPDT+DPST-NC
DC-switching
DPDT
3P3T
DPDT+DPST-NC
Relay model
MM2K
MM3K
MM4K
MM2XK
MM3XK
MM4XK
Available rated voltage
100/(110), 200/(220) VAC
12, 24, 48, 100/110, 200/220 VDC
100/(110), 200/(220) VAC
48, 100/110 VDC
200/(220) VAC
12, 24, 48, 100/110, 200/220 VDC
24, 100/110 VDC
200/(220) VAC
100/110 VDC
100/(110) VAC
100/110 VDC
1
MMK
Open Coils (with Screw Terminals)
Type
Standard
Contact form
DPDT
3P3T
DPDT+DPST-NC
DC-switching
DPDT
3P3T
DPDT+DPST-NC
Relay model
MM2KB
MM3KB
MM4KB
MM2XKB
MM3XKB
MM4XKB
Available rated voltage
100/(110), 200/(220) VAC
12, 24, 48, 100/110 VDC
100/(110), 200/(220) VAC
12, 48, 100/110 VDC
24, 100/(110), 200/(220) VAC
100/110 VDC
100/(110), 200/(220) VAC
12, 24, 48, 100/110, 200/220 VDC
200/(220) VAC
24, 100/110 VDC
24, 48, 100/110, 125, 200/220 VDC
Cased Coils (Plug-in Terminals)
Type
Standard
DP
3P
4P
DC-switching
DP
3P
4P
Conforming to auxiliary power relay
specifications
Conforming to auxiliary power relay
specifications for DC-switching
4P
4P
Contact form
Relay model
MM2KP
MM3KP
MM4KP
MM2XKP
MM3XKP
MM4XKP
MM4KP-JD
MM4XKP-JD
Available rated voltage
6, 12, 24, 100/(110), 200/(220) VAC
12, 24, 48, 100/110, 125, 200/220 VDC
24, 100/(110), 200/(220) VAC
6, 12, 24, 48, 100/110, 125, 200/220 VDC
24, 100/(110), 200/(220) VAC
6, 12, 24, 48, 100/110, 125, 200/220 VDC
24, 100/(110), 200/(220) VAC
12, 24, 48, 100/110, 125, 200/220 VDC
100/(110), 200/(220) VAC
24, 48, 100/110, 125, 200/220 VDC
100/(110), 200/(220) VAC
6, 12, 24, 48, 100/110, 125, 200/220 VDC
24, 100/(110), 115, 200/(220) VAC
24, 100/110, 125, 200/220 VDC
100/(110), 115, 200/(220) VAC
24, 48, 100/110, 125, 200/220 VDC
Model Number Legend
MM@@K@
1
2
3
1. Contact Form
2:
DPDT
3:
3PDT
4:
4PDT (open structure type)/
DPDT+DPST-NO (cased type)
2. Type (see note)
None: Standard
X:
DC-switching
3. Terminal Shape
None: Solder
B:
Screw
P:
Plug-in
Note:
The suffix “JD” indicates models conforming to auxiliary power
relay specifications.
2
MMK
■
Accessories (Order Separately)
Sockets
Relay
MM2(X)KP
DIN Track/Front-connecting Socket
Screw terminals
Back-connecting Socket
Solder terminals
11PFA
PL11
MM3(X)KP
MM4(X)KP
MM4(X)KP-JD
14PFA
14PFA
PL15
---
Mounting Brackets
Contact form
DPDT
3PDT
4PDT
Model
R99-03 (S KANAGU) FOR MM2K.611K
R99-03 (S KANAGU) FOR MM3K.612K
R99-03 (S KANAGU) FOR MM4K.613K
Specifications
■
Coil Ratings
Set Coil
Rated
voltage (V)
Open Relays
50 Hz
AC
6
12
24
50
100/
(110)
200/
(220)
DC
6
12
24
48
100/
110
200/
220
790
395
195
94
47
23.5
340
176
87
41
17/19
8.6/9.5
60 Hz
655
325
160
78
39/45
19.5/
22.5
Rated current (mA)
DP
Cased
50 Hz
690
345
170
82
41
20.5
60 Hz
590
295
145
70
35/40
17.5/
20
3P, 4P
Open Relays
Cased
DP
1.1
4.7
19
82
340
1,540
17.5
68
275
1,180
5,750
3P, 4P
0.46
1.9
8.2
34
141
563
13.4
54
255
930
4,500
DP: Approx. 2.1
3P, 4P: Approx. 2.7
% of rated
voltage
80%
max.
110%
Initial:
DP: Approx. 6.2
3P, 4P: Approx. 12
Rated:
DP: Approx. 3.5 (3.9)
3P, 4P: Approx. 6 (6.6)∗
50 Hz 60 Hz 50 Hz 60 Hz
1,285
640
320
154
77
38.5
450
220
94
52
22/24.5
11/12
1,100
550
275
132
66/76
33/38
1,165
580
290
140
70
35
1,000
500
250
120
60/68
30/34
Coil resistance
(Ω)
Set
volt.
Max
volt.
Power consumption
(VA or W)
23,200 18,000
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and
±15%
for DC coil resistance.
2.
Performance characteristic data are measured at a coil temperature of 23°C.
3.
The AC coil resistance values are reference values.
4.
The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.
∗Values
in parentheses are for open relays.
3
MMK
Reset Coil
Rated voltage (V)
AC
6
12
24
50
100/(110)
200/(220)
DC
6
12
24
48
100/110
200/220
770
385
191
92
46
23
422
215
109
58
25/27
12.2/13.5
Rated current (mA)
50 Hz
690
345
170
82
41/46
20/23
60 Hz
Coil resistance
(Ω)
2.3
9.2
35
175
739
3,030
14.2
56
220
832
4,040
16,330
Approx. 2.8
Reset voltage
80% max.
Maximum voltage
110%
% of rated voltage
Power consumption
(VA or W)
Initial: Approx. 6.5
Rated: Approx. 4.1
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and
±15%
for DC coil resistance.
2.
Performance characteristic data are measured at a coil temperature of 23°C.
3.
The AC coil resistance values are reference values.
4.
The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.
Coils (Conforming to Auxiliary Power Relay Specifications)
Rated
voltage (V)
50 Hz
AC
24
50
100/
(110)
110
115
200/
(220)
220
DC
24
48
100/
110
125
200/
220
245
117
58.5
53
51
29
26.5
94
52
22/24.5
22
11/12
Rated current (mA)
Set coil
60 Hz
210
102
51/58
46
44
25.5/
29
23
Reset coil
50 Hz
191
92
46
42
40
23
21
109
58
25/27
23.5
12.2/13.5
60 Hz
170
82
41/46
37.3
35.7
20.5/
23
18.6
Coil resistance
Set
Reset
Max. Opera-
(Ω)
voltage voltage voltage tion
level
Set
Reset
(JEC-
coil
coil
174D)
% of rated voltage
8.5
36
150
182
210
620
780
255
930
4,500
5,800
35
175
739
835
885
3,030
3,420
220
832
4,040
5,330
Approx. 2.7
Approx. 2.8
80%
max.
80%
max.
110%
A
Power consumption (VA or W)
Set coil
Initial
Rated
Reset coil
Initial
Rated
Approx. Approx. Approx. Approx.
6.3
5.1
6.5
4.1
18,000 16,330
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and
±15%
for DC coil resistance.
2.
The AC coil resistance and coil inductance values are for reference only.
3.
Performance characteristic data are measured at a coil temperature of 23°C.
4.
The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.
4
MMK
■
Contact Ratings
Standard Relays
Item
Open Relays: MM2K(B), MM3K(B), MM4K(B)
Resistive load
(cosφ = 1)
Contact mechanism
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Single
Ag
10 A at 220 VAC
7 A at 24 VDC
10 A
250 VAC, 250 VDC
10 A
2,200 VA, 168 W
5 A at 220 VAC
4 A at 24 VDC
5A
250 VAC, 250 VDC
5A
1,100 VA, 96W
Inductive load
(cosφ=0.4, L/R=7 ms)
Cased Relays: MM2KP, MM3KP, MM4KP
Resistive load
(cosφ = 1)
Inductive load
(cosφ=0.4, L/R=7 ms)
DC-switching Relays
Item
Open Relays: MM2XK(B), MM3XK(B), MM4XK(B)
Resistive load
(cosφ = 1)
Contact mechanism
Contact material
Rated load
Rated current flow
Max. switching voltage
Max. switching current
Max. switching power
(reference value)
Single
Ag
7 A at 110 VDC
10 A
250 VAC, 250 VDC
10 A
800 W, 20 VA
660 W, 20 VA
6 A at 110 VDC
5 A at 110 VDC
5A
250 VAC, 250 VDC
5A
700 W, 20 VA
600 W, 20 VA
Inductive load
(cosφ=0.4, L/R=7 ms)
Cased Relays: MM2XKP, MM3XKP, MM4XKP
Resistive load
(cosφ = 1)
Inductive load
(cosφ=0.4, L/R=7 ms)
Note: 1.
When switching DC inductive loads at 125 V or more, an unstable region exists for a switching current of between 0.5 and
2.5 A. The Relay will not turn OFF in this region. Use a switching current of 0.5 A or less when switching 125 VDC or more.
2.
If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the
circuit must be designed to ensure that an arc-breaking time of 50 ms is not exceeded.
Contacts (Conforming to Auxiliary Power Relay Specifications)
Item
Resistive load
(cosφ = 1)
Contact mechanism
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Single
Ag
5 A at 220 VAC, 4 A at 24 VDC
5A
250 VAC, 250 VDC
5A
5 A at 110 VDC
MM4KP-JD
Inductive load
(cosφ = 0.4, L/R= 7 ms)
MM4XKP-JD
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4, L/R= 7 ms)
Note: 1.
When switching DC inductive loads at 125 V or more, an unstable region exists for a switching current of between 0.5 and
2.5 A. The Relay will not turn OFF in this region. Use a switching current of 0.5 A or less when switching 125 VDC or more.
2.
If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application and the
circuit must be designed to ensure that an arc-breaking time of 50 ms is not exceeded.
5