Features
Regulated
Converters
●
●
●
●
●
●
●
2:1 Wide Range Voltage Input
1kVDC, 2kVD & 3kVDC Isolation
UL94V-0 Package Material
Continuous Short Circuit Protection
with Current Foldback
Low Noise
No External Capacitor needed
Efficiency to 83%
ECONOLINE
DC/DC-Converter
RSO
Series
Capacitive
Load max.
µF
470
470
220
100
47
470
470
220
100
47
470
470
220
100
47
470
470
220
100
47
±220
±220
±100
±47
±22
±220
±220
±100
±47
±22
±220
±220
±100
±47
±22
±220
±220
±100
±47
±22
www.recom-international.com
Selection Guide
5V, 12V, 24V and 48V Input Types
Part Number
SIP8
RSO-053.3S (H2/H3)
RSO-0505S (H2/H3)
RSO-0509S (H2/H3)
RSO-0512S (H2/H3)
RSO-0515S (H2/H3)
RSO-123.3S (H2/H3)
RSO-1205S (H2/H3)
RSO-1209S (H2/H3)
RSO-1212S (H2/H3)
RSO-1215S (H2/H3)
RSO-243.3S (H2/H3)
RSO-2405S (H2/H3)
RSO-2409S (H2/H3)
RSO-2412S (H2/H3)
RSO-2415S (H2/H3)
RSO-483.3S (H2/H3)
RSO-4805S (H2/H3)
RSO-4809S (H2/H3)
RSO-4812S (H2/H3)
RSO-4815S (H2/H3)
RSO-053.3D (H2/H3)
RSO-0505D (H2/H3)
RSO-0509D (H2/H3)
RSO-0512D (H2/H3)
RSO-0515D (H2/H3)
RSO-123.3D (H2/H3)
RSO-1205D (H2/H3)
RSO-1209D (H2/H3)
RSO-1212D (H2/H3)
RSO-1215D (H2/H3)
RSO-243.3D (H2/H3)
RSO-2405D (H2/H3)
RSO-2409D (H2/H3)
RSO-2412D (H2/H3)
RSO-2415D (H2/H3)
RSO-483.3D (H2/H3)
RSO-4805D (H2/H3)
RSO-4809D (H2/H3)
RSO-4812D (H2/H3)
RSO-4815D (H2/H3)
50
Input
Voltage Range
(VDC)
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
18 - 36
18 - 36
18 - 36
18 - 36
18 - 36
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
4.5 - 9
9 - 18
9 - 18
9 - 18
9 - 18
9 - 18
18 - 36
18 - 36
18 - 36
18 - 36
18 - 36
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
Rated Output
Voltageat
(VDC)
3.3
5
9
12
15
3.3
5
9
12
15
3.3
5
9
12
15
3.3
5
9
12
15
±3.3
±5
±9
±12
±15
±3.3
±5
±9
±12
±15
±3.3
±5
±9
±12
±15
±3.3
±5
±9
±12
±15
Output Current
Full Load
(mA)
300
200
111
83
67
300
200
111
83
67
300
200
111
83
67
300
200
111
83
67
±150
±100
±56
±42
±34
±150
±100
±56
±42
±34
±150
±100
±56
±42
±34
±150
±100
±56
±42
±34
Efficiency
typ.
(%)
68
73
74
75
75
69
75
78
80
80
70
78
81
83
83
70
75
78
80
80
71
74
75
76
76
76
79
80
81
81
74
77
78
80
80
70
75
78
80
80
January-2007
1 Watt
SIP8 Isolated
Single
&
Dual
Output
EN-60950-1 Certified
EN-60601-1 Certified
(Suffix H2/H3)
ECONOLINE
DC/DC-Converter
Description
High power-density, an industrial temperature range of -40°C to +85°C and extra features like Remote-On-
Off-control are just some of the characteristics of this converter, ideal for highly sophisticated industrial-
designs. The RSO series is available with isolation of 2kV or 3kV by chosing option "/H2" or "/H3" in which
case it is also ideal for medical applications which additionally require EN-60601-1 certification.
RSO
Series
Specifications
(Core Operating Area)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation (10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
No Load Power Consumption
Isolation Voltage
2:1
±2% typ.
±0.2% max.
±0.4% max.
50mVp-p max.
100kHz typ.
up to 83%
50mW min. / 139mW typ. / 250mW max.
(tested for 1 second)
1000VDC min.
H2
2000VDC min.
H3
3000VDC min.
(long term isolation)
see Application Notes
Single
10pF min. / 40pF typ. / 60pF max.
Single
5pF min. / 30pF typ. / 60pF max.
Dual
120pF min. / 170pF typ. / 250pF max.
Dual
5pF min. / 30pF typ. / 60pF max.
>1GΩ min.
Continuous
-40°C to +85°C (see Graph)
-55°C to +125°C
95% RH
4.6g
Detailed Information see
Application Notes chapter "MTBF"
Derating-Graph
(Ambient Temperature)
100
80
Rated Working Voltage
Isolation Capacitance (1000V version)
Isolation Capacitance (H2 and H3)
Isolation Capacitance (1000V version)
Isolation Capacitance (H2 and H3)
Isolation Resistance
Short Circuit Protection
Output Power (%)
60
40
30
20
0
Safe Operating Area
85
Operating Temperature °C
-40
0
50
100
150
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
MTBF (+25°C)
(+85°C)
}
using MIL-HDBK 217F
using MIL-HDBK 217F
1685 x 10
3
hours
254 x 10
3
hours
Typical Characteristics
RSO-24xx
Efficiency / Load
100
80
60
40
RSO-types
2
1.5
2412
2409
Output Power (W)
100%
2405
2415
Efficiency %
20
0
1
0.75
0.5
0
0%
20%
40%
60%
80%
4.5 5
6
7
8
9
Total Output current (%)
Input Voltage (V)
www.recom-international.com
January-2007
51
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
RSO
Series
3rd angle
projection
8 PIN SIP Package
9.20
11.10
3.80
Single Output
Dual Output
RECOM
RSO-xxxx
****
0.50±0.05
RECOM
RSO-xxxx
****
1 2 3
5 6 7 8
RECOM
RSO-xxxxD
****
1 2 3
5 6 7 8
0.50±0.05
Recommended Footprint Details
21.80
0.32
Bottom View
Pin Connections
Pin #
1
2
3
2.54
1.0ø+0.15/0
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC*
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
3.20
2.0
2.54
Top View
5
6
7
8
NC = No Connection
NC* = NC, but no external Connection allowed.
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Control Pin Input Current:
Voltage Set Point Accuracy
with external input/output
capacitors refer to
recommended test circuit:
Control Pin (CTRL) Input
Current, control voltage
applied via 1K resistor,
output voltage must
reduce to 0V:
10mA
typ. ± 1%
max. ±2%
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the
converter is OFF and when the pin is high ‘Z’ the converter is ON. There is no allowed low state for this pin. Voltage
to be applied via a limiting resistor with a recommended value of 1K for RSO-05xx; 3.3K for RSO-12xx; RSO-24xx
and 10K for RSO-48xx.
Pin 5 (NC)
This pin is used internally and must have no external connection.
typ. 3mA
max. 6mA
Pin 8 (NC*)
No external connection allowed.
+Vin
Lin
2
6
+Vout
DC/DC
Converter
-Vin
1
7
Cout
use low ESR capacitor Cout and input inductor Lin
to reduce output ripple and input inrush current.
0V
L
in
C
out
RS0- types
RS0- types
4.7µH ~ 100µH
22µF ~ 100µF/25V
52
January-2007
www.recom-international.com