(888) IPD-CONVerters
q
(888) 473-2668
q
www.ipdconverters.com
XWT SERIES - TRIPLE, 150 WATT
Rev. 11/2000
DESCRIPTION
XWT DC/DC converters are high power, triple output
converters that cover a wide range of applications. The
XWT features remote sense leads for accurate point of
load regulation, and has short circuit and overcurrent
protection. For single and dual output high power
solutions, see the XWS and XWD series.
FEATURES
• High Power Package
• Wide Input Range
• 12, 24, and 48V
Input Versions
• Trim and Enable Pin
• Remote Sense Pins
• 500V Isolation
Efficiency vs. Load (24V Input)
85
80
EFFICIENCY %
75
XWT2405-12
EFF. (18v)
70
EFF. (24v)
EFF. (36v)
65
TECHNICAL SPECIFICATIONS
Input
Voltage Range
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
Input Ripple Current
Reverse Input Current
Output
Setpoint Accuracy
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
±1% All Outputs
±1% V
out
All Outputs
EFFICIENCY %
60
10
20
30
40
50
60
70
80
90
100
LOAD %
10 -
18 -
36 -
20%
100% I
in
Max.
20 VDC
36 VDC
72 VDC
I
in
Max.
Efficiency vs. Load (48V Input)
90
85
80
XWT4805-12
Load Regulation I
out
Min.- I
out
Max., V
in
Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Current Limit Threshold Range, % of I
out
Rated
General
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF
†
(Bellcore TR-NWT-000332)
Safety
Weight (approx.)
±1% V
out
All Outputs
10 % All Outputs
25% I
out
4% V
out
500
µs
±10%
110% - 130%
75
XWT4805-15
70
65
10
20
30
40
50
60
70
80
90
100
LOAD %
10 ms
TTL and CMOS Compatible, Positive Logic
200 kHz
500 VDC
±0.02%/°C
-25 to +85°C
††
-40 to +125°C
105 to 115°C
95%
5 g, 10 - 55 Hz
Consult Factory
Consult Factory
15.4 oz
†
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
1
XWT SERIES - TRIPLE, 150 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
12
12
24
24
48
48
Vin Range
(Volts)
10 - 20
10 - 20
18 - 36
18 - 36
36 - 72
36 - 72
Iin Max.*
(Amps)
25.0
25.0
13.2
13.2
6.8
8.8
Vout
(Volts)
5, ±12
5, ±15
5, ±12
5, ±15
5, ±12
5, ±15
Iout Rated
(Amps)
12,
12,
15,
15,
15,
15,
±3.0
±2.5
±4.0
±3.3
±4.0
±3.3
Ripple & Noise
Pk-Pk (mV)
50/120/120
50/150/150
50/120/120
50/150/150
50/120/120
50/150/150
Efficiency
Typ. **
79%
81%
83%
83%
84%
85%
Model
XWT1205-12
XWT1205-15
XWT2405-12
XWT2405-15
XWT4805-12
XWT4805-15
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Thermal Impedance
MECHANICAL DRAWING
5.50"
(139.7mm)
#4-40 THREADED INSERTS 4PLS.
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
2.5
2.1
1.7
1.3
1.1
°C/W
°C/W
°C/W
°C/W
°C/W
2.625"(66.7mm)
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
1
8
2.250"(57.2mm)
2
9
1.875"(47.6mm)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Function
No Pin
-V
in
-V
in
3
3.50"
(88.9mm)
10
1.500"(38.1mm)
4
BOTTOM VIEW
11
1.125"(28.6mm)
5
12
0.750"(19.1mm)
6
13
0.375"(9.5mm)
7
14
0
-0.375"(-9.5mm)
-0.625"(-15.9mm)
-0.60"
(-15.2mm)
0
4.300"
(109.2mm)
+V
out1
+ Sense1
- V
out2
Common 2 & 3
+ V
out3
Tolerances
+V
in
+V
in
Enable
Case
- Sense 1
-V
out1
DIA 0.040" 13PL.
(1.0mm)
Inches:
.XX ± 0.040
.XXX ± 0.010
0.92"
(23.4mm)
(Millimeters)
.X ± 1.0
.XX ± 0.25
± 0.05
Pin:
± 0.002
(Dimensions as listed unless otherwise
specified.)
2
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
Negative Logic
Lucent Compatible Trim
Terminal Strip
Trim
Enable
Trim and Enable
Current Share
Headerless
SUFFIX
N
T
TS
1
2
3
4
Y
APPLICABLE SERIES
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
HAS, HBD, HBS, HES, QBS, QES
XWS, XWD, XWT
IAS, LES
IAD, IAS, LES, SMS
IAS, LES
SMS
Encapsulated EWS, IWS, OWS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
PIN LENGTH AND HEATSINK
OPTIONS
0.110” (2.8mm) Pin Length
0.150” (3.8mm) Pin Length
0.24” (6.1mm) Horizontal Heatsink
0.24” (6.1mm) Vertical Heatsink
0.45” (11.4mm) Horizontal
Heatsink
0.45” (11.4mm) Vertical Heatsink
0.95” (24.1mm) Horizontal
Heatsink
0.95” (24.1mm) Vertical Heatsink
8
9
1H
1V
2H
2V
3H
3V
All Units (Except SMS)
All Units (Except SMS)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
All Units (Except DIP, SIP, and SM
Packages)
Standard Pin Length is 0.180”
(4.6mm)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS
Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS
The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
4