Phase Control SCR 760 Amperes Avg 500-1300 Volts
Parameter Name | Attribute value |
package instruction | , |
Reach Compliance Code | unknow |
ECCN code | EAR99 |
Nominal circuit commutation break time | 100 µs |
Critical rise rate of minimum off-state voltage | 100 V/us |
Maximum DC gate trigger current | 150 mA |
Maximum DC gate trigger voltage | 5 V |
Maximum leakage current | 50 mA |
On-state non-repetitive peak current | 8000 A |
Maximum on-state current | 760000 A |
Maximum operating temperature | 150 °C |
Minimum operating temperature | -40 °C |
Off-state repetitive peak voltage | 1200 V |
surface mount | NO |
Trigger device type | SCR |
Base Number Matches | 1 |
C430PBX555 | C430EX555 | C430MX555 | C430NX555 | C430PAX555 | C430PCX555 | C430PX555 | C430TX555 | C430SX555 | |
---|---|---|---|---|---|---|---|---|---|
Description | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts | Phase Control SCR 760 Amperes Avg 500-1300 Volts |
Reach Compliance Code | unknow | unknown | unknow | unknown | unknow | unknow | unknow | unknow | unknow |
ECCN code | EAR99 | EAR99 | EAR99 | EAR99 | EAR99 | EAR99 | EAR99 | EAR99 | EAR99 |
Nominal circuit commutation break time | 100 µs | 100 µs | 100 µs | 100 µs | 100 µs | 100 µs | 100 µs | 100 µs | 100 µs |
Critical rise rate of minimum off-state voltage | 100 V/us | 100 V/us | 100 V/us | 100 V/us | 100 V/us | 100 V/us | 100 V/us | 100 V/us | 100 V/us |
Maximum DC gate trigger current | 150 mA | 150 mA | 150 mA | 150 mA | 150 mA | 150 mA | 150 mA | 150 mA | 150 mA |
Maximum DC gate trigger voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
Maximum leakage current | 50 mA | 50 mA | 50 mA | 50 mA | 50 mA | 50 mA | 50 mA | 50 mA | 50 mA |
On-state non-repetitive peak current | 8000 A | 8000 A | 8000 A | 8000 A | 8000 A | 8000 A | 8000 A | 8000 A | 8000 A |
Maximum on-state current | 760000 A | 760000 A | 760000 A | 760000 A | 760000 A | 760000 A | 760000 A | 760000 A | 760000 A |
Maximum operating temperature | 150 °C | 150 °C | 150 °C | 150 °C | 150 °C | 150 °C | 150 °C | 150 °C | 150 °C |
Minimum operating temperature | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C |
Off-state repetitive peak voltage | 1200 V | 500 V | 600 V | 800 V | 1100 V | 1300 V | 1000 V | 900 V | 700 V |
surface mount | NO | NO | NO | NO | NO | NO | NO | NO | NO |
Trigger device type | SCR | SCR | SCR | SCR | SCR | SCR | SCR | SCR | SCR |
Base Number Matches | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |