capacitors are specifically designed for interference-sup-
pression AC line filtering applications. Having internation-
ally recognized safety certifications, these capacitors are
well-suited for applications that require keeping potentially
disruptive or damaging line transients and EMI out of sus-
ceptible equipment. They are also an ideal solution when
needing to suppress line disturbances at the source.
Safety Certified Capacitors are classified as either X and/
or Y capacitors. Class X capacitors are primarily used in
line-to-line (across-the-line) applications. In this applica-
tion, there is no danger of electric shock to humans should
the capacitor fail, but could result in a risk of fire. The class
Y capacitor is primarily used in line-to-ground (line by-pass)
applications. In this application, failure of the capacitor
could lead to danger of electric shock.
With a working voltage of 400 VAC in line-to-line (Class X)
and 250 VAC in line-to-ground (Class Y) applications, these
safety capacitors meet the impulse test criteria outlined in
IEC Standard 60384. Meeting subclass X1 and Y2 require-
ments, these devices are certified to withstand impulses up
to 4 KV (X1) and 5 KV (Y2) respectively. These encapsulated
devices also meet the flame test requirements outlined in UL
Standard 94V–0.
Click image above for interactive 3D content
Ordering Information
C9
Ceramic
Series
C9 =
Ceramic
900
Open PDF in Adobe Reader for full functionality
8
Body
Diameter
0 = 7.0 mm
1 = 8.0 mm
2 = 9.0 mm
3 = 10.0 mm
4 = 11.0 mm
6 = 13.0 mm
8 = 15.0 mm
1
Lead
Spacing
1,2,4
5 = 5.0 mm
7 = 7.5 mm
1 = 10.0 mm
U
Spec.
U=
Safety
103
M
Y
V
D
A
Lead
Config.
1,3,4
A = Straight
B = Vertical
Kink
C = Outside
Kink
D = Inside
Kink
A
Failure
Rate
A=
N/A
7317
Packaging
(C-Spec)
See
"Packaging
C-Spec
Ordering
Options
Table"
below
Capacitance Capacitance
Code (pF)
Tolerance
Two
significant
digits and
number of
zeroes
J = ±5%
K = ±10%
M = ±20%
Rated
Dielectric/
Design
Voltage Temp. Char.
Y=
X1 400
VAC/
Y2 250
VAC
S = SL
Y = Y5P
W = Y5U
V = Y5V
D=
Disc
Due to a high risk of arcing, "Inside Kink" lead configuration cannot be combined with the 5 mm lead spacing option. The "Inside Kink" option is only
available on capacitors with lead spacing of 7.5 mm or greater. A potential for arcing may exist when combining the "Inside Kink" lead configuration
with a 7.5 mm lead spacing option, especially in high humidity environments and/or when exposure to voltages and transients may impact creepage
and clearance requirements.
2
Capacitor body diameter will limit available lead spacing and packaging options. See "Dimensions" and "Product Ordering Codes and Ratings" sections
of this document to determine availability.
3
"Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact
KEMET.
4
Bulk packaging lead length availability is dependent upon "Lead Configuration" and "Lead Spacing." See "Dimensions" section of this document to
verify availability of a specific lead length option. For nonstandard lead length inquiries, please contact KEMET.
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)
Packaging C-Spec Ordering Options Table
Packaging Type
Ammo Pack
Lead Length
(mm)
2,3
20.0 +1.5/−1.0 (straight leads)
18.0 +2.0/−0 (preformed leads
1
)
3.0 ±1.0
3.5 ±1.0
4.0 ±1.0
4.5 ±1.0
5.0 ±1.0
20.0 minimum
4
Packaging
Ordering Code (C-Spec)
7317
WL30
WL35
WL40
WL45
WL50
WL20
Bulk Bag
Preformed (crimped) lead configurations include "Vertical Kink", "Outside Kink" and "Inside Kink". See "Lead Configurations" and "Ordering
Information" sections of this document for further details.
2
"Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact
KEMET.
3
For nonstandard lead length inquiries, please contact KEMET.
4
Lead length of 20.0 mm minimum only available for straight leads.
1
Benefits
•
•
•
•
•
•
•
•
•
•
•
•
Safety standard recognized (IEC 60384–14)
Reliable operation up to 125°C
Class X1/Y2
5.0 mm, 7.5 mm, and 10 mm lead spacing
Lead (Pb)-free and RoHS Compliant
Halogen-free
Capacitance offerings ranging from 10 pF up to 10 nF
Available capacitance tolerances of ±5%, ±10%, and ±20%
High reliability
Preformed (crimped) or straight lead configurations
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)
Table 1 – Product Ordering Codes and Ratings
Dimensions (mm)
Dielectric/
Temp. Char.
KEMET
Part Number
C90(1)U100JYSD(2)A(3)
C90(1)U120JYSD(2)A(3)
C90(1)U150JYSD(2)A(3)
C90(1)U180JYSD(2)A(3)
C90(1)U200JYSD(2)A(3)
C90(1)U220JYSD(2)A(3)
C90(1)U240JYSD(2)A(3)
C90(1)U270JYSD(2)A(3)
C90(1)U300JYSD(2)A(3)
C90(1)U330JYSD(2)A(3)
C90(1)U360JYSD(2)A(3)
C90(1)U390JYSD(2)A(3)
C90(1)U470JYSD(2)A(3)
C90(1)U500JYSD(2)A(3)
C90(1)U510JYSD(2)A(3)
C91(1)U560JYSD(2)A(3)
C91(1)U620JYSD(2)A(3)
C91(1)U680JYSD(2)A(3)
C91(1)U750JYSD(2)A(3)
C92(1)U820JYSD(2)A(3)
C93(1)U101JYSD(2)A(3)
C90(1)U101KYYD(2)A(3)
C90(1)U151KYYD(2)A(3)
C90(1)U221KYYD(2)A(3)
C90(1)U331KYYD(2)A(3)
C90(1)U471KYYD(2)A(3)
C91(1)U561KYYD(2)A(3)
C91(1)U681KYYD(2)A(3)
C92(1)U821KYYD(2)A(3)
C92(1)U102KYYD(2)A(3)
C90(1)U102MYWD(2)A(3)
C92(1)U152MYWD(2)A(3)
C92(1)U222MYWD(2)A(3)
C94(1)U332MYWD(2)A(3)
C96(1)U392MYWD(2)A(3)
C96(1)U472MYWD(2)A(3)
C90(1)U102MYVD(2)A(3)
C90(1)U152MYVD(2)A(3)
C90(1)U222MYVD(2)A(3)
C92(1)U332MYVD(2)A(3)
C94(1)U392MYVD(2)A(3)
C94(1)U472MYVD(2)A(3)
C96(1)U682MYVD(2)A(3)
C98(1)U103MYVD(2)A(3)
KEMET Part Number
Lead Spacing
Lead
Diameter
Bulk
Packaging
Ammo
Packaging
Capacitance
10 pF
12 pF
15 pF
18 pF
20 pF
22 pF
24 pF
27 pF
30 pF
33 pF
36 pF
39 pF
47 pF
50 pF
51 pF
56 pF
62 pF
68 pF
75 pF
82 pF
100 pF
100 pF
150 pF
220 pF
330 pF
470 pF
560 pF
680 pF
820 pF
1,000 pF
1,000 pF
1,500 pF
2,200 pF
3,300 pF
3,900 pF
4,700 pF
1,000 pF
1,500 pF
2,200 pF
3,300 pF
3,900 pF
4,700 pF
6,800 pF
10,000 pF
Capacitance
Capacitance
Tolerance
Body Diameter
(Maximum)
Body Thickness
(Maximum)
7.0
5 mm,
7.5 mm,
or
10 mm
SL
±5%
5.0
0.55 ±0.1
8.0
9.0
10.0
7.0
±10%
8.0
9.0
7.0
±20%
9.0
11.0
13.0
5.0
0.55 ±0.1
5.0
0.55 ±0.1
Y5P
5 mm,
7.5 mm,
or
10 mm
5 mm, 7.5 mm, or 10 mm
Y5U
7.5 mm or 10 mm
7.0
±20%
9.0
11.0
13.0
15.0
Capacitance Tolerance
Body Diameter
(Maximum)
Body Thickness
(Maximum)
Lead Diameter
5.0
0.55 ±0.1
5 mm, 7.5 mm, or 10 mm
Y5V
7.5 mm or 10 mm
Lead Spacing
(1) To properly complete ordering code, insert the one-digit numeric code to reflect required lead spacing: (Note that select capacitance values and packaging
options may limit lead spacing availability. See table above to verify availability.)
5 = 5.0 mm
7 = 7.5 mm
1 = 10.0 mm
(2) To properly complete ordering code, insert the one-digit character code to reflect the required lead configuration: (See "Lead Configuration" section of this
document, page 2, for further details.)
A = Straight
B = Vertical Kink
C = Outside Kink
D = Inside Kink (not available with 5 mm lead spacing option)
(3) To properly complete ordering code, enter the four-digit numeric or alphanumeric "Packaging C-Spec Ordering Code." See "Dimensions" section of this
Efficiency and accuracy are two major advantages, but implementing POL conversion requires careful attention to regulator design.Proximity to the source. This is one of the best ways to improve the vo...
[size=5][color=#000000][backcolor=lightblue]The designer of the London Underground steps may be a programmer... [/backcolor][/color][/size][backcolor=lightblue][font=Arial, "][size=5][color=#000000]So...
Sipeed LicheeRV 86 development board, why is it called 86:86 panel usually refers to the panel of household switches, sockets, information sockets, etc. Because the length and width are both 86 mm, th...
[size=4] When driving a motorcycle, it is often difficult to hear the ringing sound of the mobile phone because the vehicle itself and the surrounding environment are noisy, which is very inconvenient...
The smart building revolution is underway, delivering improved comfort and convenience to residences, lower operating costs and increased employee productivity in the commercial sector. The global mar...