General Purpose Relay
G7L
• Ideally suited for high-inrush fluid pump controls: pool/spa, water
processing, emergency, chemical industry, etc.
• High-capacity, high-withstand voltage relay with no contact chatter-
ing for momentary voltage drops up to 50% of rated voltage.
• UL Class B construction standard.
• Wide-range AC-activated coil that handles 100 to 120 VAC at either
50 or 60 Hz.
• Miniature hinge for maximum switching capacity, particularly for in-
ductive loads.
• Flame resistant materials (UL94V-0-qualifying) used for
all insulation material.
• Quick-connect, screw, and PCB terminals available.
• Standard models are UL, CSA, and TUV approved;
VDE/IEC 950 versions are now available. Meet pollution degree 3,
Material Group II & III.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
Type
E bracket (see note 1)
E bracket (see note 1)
(with test button)
Upper bracket
Upper bracket
(with test button)
PCB mounting
Contact form
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
Quick-connect terminal
G7L-1A-T-CB
G7L-2A-T-CB
G7L-1A-TJ-CB
G7L-2A-TJ-CB
G7L-1A-TUB-CB
G7L-2A-TUB-CB
G7L-1A-TUBJ-CB
G7L-2A-TUBJ-CB
—
—
Model
Screw terminal
G7L-1A-B-CB
G7L-2A-B-CB
G7L-1A-BJ-CB
G7L-2A-BJ-CB
G7L-1A-BUB-CB
G7L-2A-BUB-CB
G7L-1A-BUBJ-CB
G7L-2A-BUBJ-CB
—
—
PCB terminal
—
—
—
—
—
—
—
—
G7L-1A-P-CB
G7L-2A-P-CB
Note: 1.
E bracket or socket must be used for mounting (part number R99-07G7L). Refer to “Accessories” section for options and part numbers.
2.
For VDE approved versions, please consult OMRON.
3.
CE marking is provided only on non-PCB terminal versions.
General Purpose Relay
G7L
329
■
Model Number Legend
G7L-
❏ ❏
-
❏ ❏ ❏ ❏
1 2 3 4 5 6
1. Contact form
1A:SPST-NO
2A:DPST-NO
2. Terminal shape
T:Quick-connect terminals
P:PCB terminals
B:Screw terminals
3. Mounting construction
No symbol:E bracket type
UB:Upper bracket type
4. Special functions
No symbol:Without test button
J:With test button
5. 80: VDE approved version
(includes UL, CSA and TÜV)
6. CB: Class B insulation
7. Rated coil voltage
■
Accessories
Quick-connect Terminals
Description
SPST-NO
G7L-1A-TJ
Model
Contact form
G7L-1A-T
G7L-2A-T
DPST-NO
G7L-2A-TJ
Model
E-brackets
Track mounting adaptor
Front connecting socket
R99-07G7L
P7LF-D
P7LF-06
Note:
A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.
Screw Terminals
Description
SPST-NO
G7L-1A-BJ
Model
Contact form
G7L-1A-B
G7L-2A-B
DPST-NO
G7L-2A-BJ
Model
E-brackets
Track mounting adaptor
Terminal Cover
R99-07G7L
P7LF-D
P7LF-C
Note:
The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.
Specifications
■
Contact Data
G7L-1A-T, G7L-1A-B
G7L-2A-T, G7L-2A-B
Resistive load
Inductive load
Resistive load
Inductive load
(cosφ = 1)
(cosφ = 0.4)
(cosφ = 1)
(cosφ = 0.4)
Rated load
30 A, 220 VAC
25 A, 220 VAC
Contact material
AgSnIn
Carry current
30 A
25 A
Max. operating voltage
250 VAC
Max. operating current
30 A
25 A
Max. switching capacity
6,600 VA
5,500 VA
Min. permissible load
100 mA, 5 VDC (please inquire for lower minimum rating)
Note:
P level:
λ
60
= 0.1 x 10
-6
operation.
Load
G7L-1A-P, G7L-2A-P
Resistive load
Inductive load
(cosφ = 1)
(cosφ = 0.4)
20 A, 220 VAC
20 A
20 A
4,400 VA
■
Coil Internal Circuit
DC operating coil
AC operating coil
330
General Purpose Relay
G7L
■
Coil Data
AC
Rated voltage
(V)
6
12
24
50
100/120
200/240
Rated current
(mA)
283
142
71
34
17.00/20.40
8.50/10.20
Resistance
(Ω)
18.90
75
303
1,310
5,260
21,000
Must operate
75% max.
Must release
Max. voltage
% of rated voltage
15% min.
110% max.
Power
consumption
Approx.1.70
to 2.50 VA
75 volts
150 volts
18 volts
36 volts
132 volts
264 volts
DC
Rated voltage
(V)
6
12
24
48
100
Rated current
(mA)
317
158
79
40
19
Resistance
(Ω)
18.90
75
303
1,220
5,260
Must operate
75% max.
Must release
Max. voltage
% of rated voltage
15% min.
110% max.
Power
consumption
Approx.1.90 W
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for AC rated cur-
rent and
±15%
for DC coil resistance.
2.
Performance characteristic data are measured at a coil temperature of 23°C (73°F).
■
Characteristics
Contact resistance
Operate time
Release time
Max. operating
frequency
Insulation resistance
Dielectric strength
Mechanical
Electrical
50 mΩ max.
30 ms max.
30 ms max.
1,800 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts
2,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
Impulse withstand voltage
Vibration
Mechanical
durability
Malfunction
durability
Mechanical
durability
Malfunction
durability
Mechanical
Electrical
Ambient temperature
Humidity
Weight
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (DPST-NO type)
Between coil and contact: 10,000 V min./12,000 V typ. (impulse wave used: 1.20 x 50
μs)
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
1,000 m/s
2
(approx. 100 G)
100 m/s
2
(approx.10 G)
1,000,000 operations min. (at 1,800 operations/hour)
100,000 operations min. (at 1,800 operations/hour under rated load 250,000 ops typical)
-25° to 60°C (-13° to 140°F)
35% to 85% RH
Quick-connect terminal type: approx. 90 g (3.17 oz)
PCB terminal type: approx. 100 g (3.52 oz)
Screw terminal type: approx. 120 g (4.23 oz)
Shock
Life expectancy
Note:
Data shown are of initial value.
General Purpose Relay
G7L
331
■
Characteristic Data
Maximum switching capacity
Electrical service life
Service life (x 10
3
operations)
Switching current (A)
Switching voltage (V)
Switching current (A)
Dimensions
Unit: mm (inch)
■
Relays
G7L-1A-T
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-T
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
* E bracket must be ordered separately.
332
General Purpose Relay
G7L
G7L-1A-TJ
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-TJ
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-1A-TUB
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-TUB
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
*E bracket must be ordered separately.
General Purpose Relay
G7L
333