NH DIN Dual Indication Fuse Links
With Insulated Metal Gripping Lugs
Class of Operation gL/gG, 400V AC, 2 to 630 Amps
Sizes 000 to 3
Standards/
Approvals:
Description:
Packaging:
Technical Data:
Rated Voltage:
Rated Breaking Capcity:
Rated Frequency:
Operating Frequency:
Design -Insulator:
-Metal Parts:
Contact Blade:
Environmental:
Cooper Bussmann
®
Bussmann
®
NH
IEC 60269, VDE0636,
DIN 43 620 Part 1 to 4.
A square bodied range of industrial fuse
links for a wide variety of applications.
All fuse links are packed in 3’s.
400V AC
120kA
50Hz
45-62 Hz
Steatite
Corrosion-proof (aluminium)
Full contact blades,
Silver plated copper
100% recyclable
Cadmium & lead free for sizes 000 to 3
(2A to 630A)
CATALOGUE SYMBOL: (amp)NHG(Size)BI-400
HRC FUSE LINKS
CLASS OF OPERATION gL/gG
400V AC
2 to 630 AMPS
SIZES 000 to 3
Dimensional Data
Size
a
000
00
01
1
02
2
03
3
a1
78.5 ± 1.5
78.5 ± 1.5
135 ± 2.5
135 ± 2.5
150 ± 2.5
150 ± 2.5
150 ± 2.5
150 ± 2.5
a2
(max)
54
54
75
75
75
75
75
75
a3
45 ± 1.5
45 ± 1.5
62 ± 2.5
62 ± 2.5
62 ± 2.5
62 ± 2.5
62 ± 2.5
62 ± 2.5
a4
49 ± 1.5
49 ± 1.5
68 ± 2.5
68 ± 2.5
68 ± 2.5
68 ± 2.5
68 ± 2.5
68 ± 2.5
b
(nom)
15
15
15
20
20
25
25
32
c1(± 8)
35
35
40
40
48
48
60
60
c2
(nom)
10
10
11
11
11
11
11
11
D
(nom)
2 ± 0.5
2 ± 0.5
2.5 ± 0.5
2.5 ± 0.5
2.5 ± 0.5
2.5 ± 0.5
2.5 ± 0.5
3 ± 0.5
e1 (max)
41
48
48
53
53
61
61
76
e2
(max)
21
30
30
52
52
60
60
75
e3
(max)
21
25
25
25
25
25
25
25
e4
(nom)
6
6
6
6
6
6
6
6
f
(max)
8
15
15
15
15
15
15
18
Form No. NH
Page 1 of 7
Data sheet 720097
NH DIN Dual Indication Fuse Links
Time Current Characteristics for Size 000
Cooper Bussmann
®
Bussmann
®
Class of Operation gL/gG, 400V AC, 2 to 100 Amps
Sizes 000
NH
Size 000 Details:
Standards/Approvals:
Rated Currents:
Part
Number
2NHG000B-400
4NHG000B-400
6NHG000B-400
10NHG000B-400
16NHG000B-400
20NHG000B-400
25NHG000B-400
32NHG000B-400
35NHG000B-400
40NHG000B-400
50NHG000B-400
63NHG000B-400
80NHG000B-400
100NHG000B-400
Amp
Rating
2
4
6
10
16
20
25
32
35
40
50
63
80
100
IEC60269, DIN 43 620, VDE0636
2, 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80 & 100 Amps
Minimum
Pre-arcing
4
6
14
58
234
584
1000
2400
2900
4000
4000
6000
9900
18100
I
2
t(Ampere
2
seconds)
I1 120kA
@ 400Vac
6
12
21
174
800
1800
2800
7200
8500
12300
13600
20400
35700
39800
Watts
Loss
3.9
1.4
2.2
1.5
2.3
2.2
3.1
2.8
2.8
3.0
3.4
4.5
4.7
5.3
Net weight
per fuse
Rated
Voltage
Form No. NH
Page 2 of 7
Data sheet 720099
NH DIN Dual Indication Fuse Links
Time Current Characteristics for Size 00
Cooper Bussmann
®
Bussmann
®
Class of Operation gL/gG, 400V AC, 125 & 160 Amps
Sizes 00
NH
Size 00 Details:
Standards/Approvals:
Rated Currents:
IEC60269, DIN 43 620, VDE0636
125 & 160 Amps
Part
Number
125NHG00B-400
160NHG00B-400
Amp
Rating
125
160
Minimum
Pre-arcing
25000
60000
I
2
t(Ampere
2
seconds)
I1 120kA
@ 400Vac
126000
80000
Watts
Loss
8.0
7.8
Net weight
per fuse
0.185 kg
Rated
Voltage
400Vac
Form No. NH
Page 3 of 7
Data sheet 720099
NH DIN Dual Indication Fuse Links
Time Current Characteristics for Size 01 & 1
Cooper Bussmann
®
Bussmann
®
Class of Operation gL/gG, 400V AC, 35 to 250 Amps
Sizes 01 & 1
NH
Size 01 & 1 Details:
Standards/Approvals:
Rated Currents:
IEC60269, DIN 43 620, VDE0636
35, 40, 50, 63, 80, 100, 125, 160, 200, 224 & 250 amps
Part
Number
35NHG01B-400
40NHG01B-400
50NHG01B-400
63NHG01B-400
80NHG01B-400
100NHG01B-400
125NHG01B-400
160NHG01B-400
200NHG1B-400
224NHG1B-400
250NHG1B-400
Amp
Rating
35
40
50
63
80
100
125
160
200
224
250
I
2
t(Ampere
2
seconds)
Minimum
I1 120kA
Pre-arcing
@ 400Vac
2400
3300
4200
6600
9600
16000
24000
53000
89000
119000
171000
7600
10600
10400
16300
33600
56000
86400
111300
232000
322000
479000
Watts
Loss
4.9
5.0
4.7
5.6
5.6
6.8
8.8
8.9
12.0
12.0
14.0
Net weight
per fuse
Rated
Voltage
0.269kg
400Vac
0.387kg
Form No. NH
Page 4 of 7
Data sheet 720099
NH DIN Dual Indication Fuse Links
Time Current Characteristics for Size 02 & 2
Cooper Bussmann
®
Bussmann
®
Class of Operation gL/gG, 400V AC, 35 to 400 Amps
Sizes 02 & 2
NH
Size 02 &2 Details:
Standards/Approvals:
Rated Currents:
IEC60269, DIN 43 620, VDE0636
35, 40, 50, 63, 80, 100, 125, 160, 200,
224, 250, 315, 355 and 400 Amps
Amp
Rating
35
40
50
63
80
100
125
160
200
224
250
315
355
400
I
2
t(Ampere
2
seconds)
Watts
Loss
4.4
5.0
6.5
5.5
5.5
6.6
8.7
10.0
12.0
12.0
14.0
19.0
22.0
24.0
Net weight
per fuse
Rated
Voltage
Part
Number
35NHG02B-400
40NHG02B-400
50NHG02B-400
63NHG02B-400
80NHG02B-400
100NHG02B-400
125NHG02B-400
160NHG02B-400
200NHG02B-400
224NHG02B-400
250NHG02B-400
315NHG2B-400
355NHG2B-400
400NHG2B-400
Minimum
Pre-arcing
2400
3300
4200
6600
10000
16000
24000
50000
89000
119000
171000
280000
350000
504000
I1 120kA
@ 400Vac
7600
10600
10400
16300
34800
56000
86400
185000
232000
322000
479000
924000
1155000
1673100
0.402kg
400Vac
0.630kg
Form No. NH
Page 5 of 7
Data sheet 720099