Packaging
Specification
General Cable Assembly Label or Print Specification
1.
SCOPE
107-93008
21/Feb/2013 Rev.D
This specification covers the supplier’s requirements and indications for TE Connectivity
(Enterprise Networks), Copper cable assemblies product mark.
2.
APPLICABLE DOCUMENTS
Product drawing indications shall take precedence.
3.
MATERIALS
Label Type “A” (PN 3-161183-4) or other TE Connectivity approved label.
Label Type “B” (PN 1-1768834-3) or other TE Connectivity approved label.
Label Type “C” or other TE Connectivity approved label.
4.
LABELLING AND PRINTING CONDITIONS
A label is always required, as at least one of the following conditions is met:
The cable already contains a printing from the cable manufacturer (to avoid overlapping).
On 1 pair cable (due to reduced cable diameter).
On unprinted multi-pair cable, a label is not required, and then proceeds to CABLE PRINT per fig.2.
“Pre-printed cable assembly label” or “cable print” with the same specification should be positioned
with the text in longitudinal direction (parallel with cable length) according to figures 1 and 2. It has to
be clear and readable.
Fig.1
“PRE-PRINTED CABLE
ASSEMBLY LABEL”
Fig. 2
“CABLE PRINT”
For cable assemblies < 300mm the label or print will be placed in the middle of the cable.
©2013 TE Connectivity.
Kessel-Lo (Belgium)
All International Rights Reserved
* Trademark
| Indicates change
*AMP NETCONNECT,TE Connectivity, TE Connectivity (logo) and TE (Logo) are
trademarks. Other logos, product and/or company names may be trademarks of their
respective owners.
1 of 4
LOC
107-93008
5.
“LABEL TYPE” & “CABLE PRINTING”: CONTENT AND LAYOUT
Label types:
RELATED PRODUCT FAMILY
“Cable assembly”
(shown on
table 1)
MRJ21 “cable assembly”
“AMP SIGMA-Link Classic” and “Jack Cable
assembly” (Shown on
table 2)
SKETCH SHOWN ON
Fig.3
Fig.4
Fig.5
“LABEL TYPE”
A
B
C
In case that additional labels are needed due to new specific requirements, new letters for
label type will be assigned.
“Label
Type”
Sketch for reference only
(example of zone AxB )
1-0346925-2
(1)
Figure for reference only (example
of printable zone AxB )
View* for ref. only
(Dim. AxBxC)
A
PC Cat 5e 12,5m
(2)
CE Mark
(4)
0529 - 416936 – Rev. X
(3)
Fig.3
*Dimensions AxBxC could be according to PN 3-161183-4 (as shown) or other approved by TE Connectivity.
Meaning of fields:
TE Connectivity material number (X-XXXXXXX-X)
(1)
Short material description according to
table 1
(2)
Batch – MI – Rev. X
(3)
“CE” Mark
(4)
Detailed comments:
> Batch: It is the manufacturing date code. Format YYWW: (according to Spec 102-60).
> MI (Manufacturing identity): It is the SAP vendor code.
> Rev. X: where X is the part revision number as defined in the PN Rev. per Production Order.
> “CE” marking: According to RoHS 2 Directive (2011/65/EU and reg. EC Nº 765/2008, Art. 30.
Annex II. CE Marking, at least 5 mm high).
Font: Arial Narrow 7, Bold (Font high ≈ 2mm) or other approved by Engineering, except the CE marking.
“Label Type”
Sketch for reference only
(example)
“COMPANY NAME”
(1)
CE Mark
(4)
“PN-[ ]”
(2)
“Length” (MTS)
(3)
“DATE CODE” & “MI” (5)
“SERIAL NUMBER”
(6)
“MADE IN____”
(7)
Figure for reference only
(example)
B
Fig.4
Meaning of the fields:
Company Name (TE
Connectivity) (1)
TE Connectivity material number (Part Number).(X-XXXXXXX-X)
(2)
Length (MTS)
(3)
“CE” Mark
(4)
Date Code and MI
(5)
Serial Number
(6)
Made in _ _ _ (7)
2 of 4
KLO-107
Rev D
107-93008
Detailed comments:
> Batch: It is the manufacturing date code. Format YYWW: (according to Spec 102-60).
> MI (Manufacturing identity): It is the SAP vendor code.
> Serial Number: Unique Serial number per assy. defined by vendor.
> “CE” marking: According to RoHS 2 Directive (2011/65/EU and reg. EC Nº 765/2008, Art. 30.
Annex II. CE Marking, at least 5 mm high).
> Made in (it is the manufacturing location –Country- for Final Good).
Font: Arial Narrow 7, Bold (Font high ≈ 2mm) or other approved by Engineering, except the CE marking.
“Label Type”
Sketch for reference only
(example)
“TE PN”
(1)
“Material Description & Length”
(2)
Date code - MI – Rev. X
(3)
“SERIAL NUMBER” (5) CE Mark
(4)
Figure for reference only
(example)
C
Fig.5
Meaning of the fields:
TE Connectivity material number (Part Number).(X-XXXXXXX-X)
(1)
Short material desc. according to
table 2
(only for reference) and Length in meters (m.)
(2)
Date Code – MI – Rev. X
(3)
“CE” Mark
(4).
Serial Number
(5)
Detailed comments:
> Batch: It is the manufacturing date code. Format YYWW: (according to Spec 102-60).
> MI (Manufacturing identity): It is the SAP vendor code.
> Serial Number: Unique Serial number per assy. defined by vendor.
> “CE” marking: According to RoHS 2 Directive (2011/65/EU and reg. EC Nº 765/2008, Art. 30.
Annex II. CE Marking, at least 5 mm high).
Font: Arial Narrow 7, Bold (Font high ≈ 2mm) or other approved by Engineering, except the CE marking.
Cable Print:
Same criteria than label Type “A”, as shown on figures 1 and 2.(Sketch shown on fig. 6 is for reference
only).
1-0346925-2
(1)
PC Cat 5e 12,5m
(2)
0529 – 416936 – Rev. X
(3)
CE
(4)
Fig. 6
case that “CE” mark is printed over the cable jacket (dot matrix printer format), the
acceptance criteria is as follow. (Views shown for reference only).
(4)
In
Rev D
3 of 4
KLO-107
107-93008
6.
SHORT MATERIAL DESCRIPTION
The short materials descript. is indicated on and must be according to production drawing.
Table 1
is
for reference only.
Cable assy. type
Perform. level
Cat 5
Cat 5e
Construction
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Shielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Shielded
Shielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Shielded
Shielded
Short mat. Description
(ZZ. m; length in meters)
PC Cat 5e Z.Zm
Patch Cord
Cat 6
Class E
A
Cat 6
A
Cat 7
A
Cat 5e
PC Cat 6 Z.Zm
PC Cat.6 Z.Zm
PC Cat 6
A
Z.Zm
PC Cat 7
A
Z.Zm
SE PC Cat 5e Z.Zm
SE PC Cat 6 Z.Zm
SE PC Class E
A
Z.Zm
SE PC Cat 6
A
Z.Zm
SE PC Cat 7
A
Z.Zm
CPT Class D Z.Zm
CPT Class E Z.Zm
CPT Class E
A
Z.Zm
CPT Class F
A
Z.Zm
Single Ende
Patch Cord
Cat 6
Class E
A
Cat 6
A
Cat 7
A
Class D
Consolidation
Point Transition
Class E
Class E
A
Class F
A
Table 1
Cable assy. type
Perform. level
Class E
Construction
Unshielded
Short mat. Description
(ZZ. m; length in meters)
S-Link UTP Class E / C to C Z.Z m
S-Link UTP Class E / C to J Z.Z m
S-Link UTP Class E / C to E Z.Z m
S-Link STP Class EA / C to C Z.Z m
Sigma Link
Classic
Cable assy.
Class EA
Shielded
S-Link STP Class EA / C to J Z.Z m
S-Link STP Class EA / C to E Z.Z m
S-Link STP Class EA / C to C Z.Z m
Class FA
Class EA
Shielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Shielded
Shielded
S-Link STP Class EA / C to J Z.Z m
S-Link STP Class EA / C to E Z.Z m
S-Link STP Class EA / C to P Z.Z m
Jack Cable Assy.
(Link)
Class D
Class E
Class E
A
Class F
A
JC/A Class D Z.Zm
JC/A Class E Z.Zm
JC/A Class E
A
Z.Zm
JC/A Class F
A
Z.Zm
Table 2
7.
REVISION SUMMARY
Rev. D: Document fully updated according to new TE Logos. In addition; material, method and label
types (Paragraph §3, 4, 5 and 6) have been also updated, including the “CE” marking requirement.
(RoHS 2 Directive).
Rev D
4 of 4
KLO-107