Features
●
●
●
●
●
●
●
●
2:1 Wide Input Voltage Range
60 Watts Output Power
1.6kVDC Isolation
Fixed Operating Frequency
Six-Sided Continuous Shield
Design Meet Safety Standard
Standard 100.2 x70.0x19.0mm Package
Efficiency to 90%
POWERLINE
DC/DC-Converter
RP60-
S_DE
Series
60 Watt
Single, Dual
&
Positive Dual
Output
Selection Guide
12V, 24V and 48V Input Types
Part Number
Input
Range
VDC
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
9-18
9-18
9-18
18-36
18-36
18-36
36-75
36-75
36-75
9-18
18-36
36-75
Output
Voltage
VDC
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
±5
±12
±15
±5
±12
±15
±5
±12
±15
3.3 / 5
3.3 / 5
3.3 / 5
Output
Current
mA
15000
12000
5000
4000
15000
12000
5000
4000
15000
12000
5000
4000
±2500
±2000
±2500
±2000
±2500
±2000
6000 / 6000
6000 / 6000
6000 / 6000
Input
(4)
Current
mA
5430
6330
6250
6250
2750
3090
2980
2940
1310
1520
1470
1450
6250
6250
3050
3010
1450
1450
5770
2700
1310
Efficiency
(5)
%
80
83
84
84
79
85
88
89
83
86
89
90
81
84
84
84
86
87
85
90
90
Capacitive
(6)
Load max.
µF
38700
20400
3550
2300
38700
20400
3550
2300
38700
20400
3550
2300
17000 / 3400
±900
±600
12000 / 1700
±900
±600
12000 / 1700
±900
±600
RP60-123.3SE
RP60-1205SE
RP60-1212SE
RP60-1215SE
RP60-243.3SE
RP60-2405SE
RP60-2412SE
RP60-2415SE
RP60-483.3SE
RP60-4805SE
RP60-4812SE
RP60-4815SE
RP60-1205DE
RP60-1212DE
RP60-1215DE
RP60-2405DE
RP60-2412DE
RP60-2415DE
RP60-4805DE
RP60-4812DE
RP60-4815DE
RP60-123.305DE
RP60-243.305DE
RP60-483.305DE
+10000 / -2000 6500
+10000 / -2000 3130
+10000 / -2000 1540
76 16000 / 10200
81 16000 / 10200
83 16000 / 10200
258
April-2005
www.recom-international.com
POWERLINE
DC/DC-Converter
RP60-S_DE
Series
125
100
75
Output Power (%)
50
25
0
-25
0
25 35 50 60
70 80 90 100
Derating-Graph
(Ambient Temperature)
Natural Convection
Ambient Temperature Range (°C)
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at info@recom-development.at
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
12V Input
24V Input
48V Input
9-18VDC
18-36VDC
36-75VDC
Pi Type
36VDC
50VDC
100VDC
40mAp-p
DC-DC ON
DC-DC OFF
Nominal input
25ms typ.
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
30mA
60W max.
±2%
RP60-xx3.305DE 3.3V Output
others
±10%
800mA min.
10% of FL
±0.5%
±0.5%
±5%
1%/p-p of Vout max.
±0.02%/°C, max.
3.3V
5V
12V
15V
500µS
3.9V
6.2V
15V
18V
Hiccup, automatic recovery
see „Selection Guide“ table
continued on next page
www.recom-international.com
April-2005
259
Input Filter
Input Surge Voltage (100 ms max.)
Input Reflected Ripple (nominal Vin and full load)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 7)
Remote OFF input current
Output Power
Output Voltage Accuracy (full Load and nominal Vin)
Voltage Adjustability
Minimum Load
Line Regulation (LL-HL at full load)
Load Regulation (25% to 100% FL)
Cross Regulation (Note 8)
Ripple and Noise (20MHz bandwith)
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
Short Circuit Protection
Efficiency
POWERLINE
DC/DC-Converter
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Operating Frequency
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance
Thermal Shock
Vibration
Relative Humidity
Case Material
Base Material
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Weight
Dimensions
MTBF (see note 2)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Natural convection
RP60-S_DE
Series
1.600VDC min.
10
9
Ω
min.
1000pF max.
200kHz typ.
-25°C to +71°C(with derating)
+95°C
-25°C to +105°C
5.2°C/Watt
MIL-STD-810D
10-55Hz, 2G, 30 Min. along X, Y and Z
5% to 95% RH
Nickel-Coated copper
Non-conductive black plastic FR4
Epoxy (UL94-V0)
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
48g
100.2 x 70.0 x 19.0mm
1.533 x 10
6
Hours
Notes :
1. The RP60 series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage
these devices, however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load.
8. See application notes for EMI-filtering.
260
April-2005
www.recom-international.com
POWERLINE
DC/DC-Converter
Package Style and Pinning (mm)
RP60-S_DE
Series
3rd angle
projection
100.20
19.0
1.3
8.0
70.00
Monting inserts: #4-40
25.40
25.00
10.00
10.00
10.00
15.00
10.00
82.60
1
Pin Connections
Pin #
Single
1
+Vin
2
-Vin
3
CTRL
4
Trim
5
+Vout
6
+Vout
7
-Vout
8
-Vout
9
No Pin
10
No Pin
NC = No Connection
Dual
+Vin
-Vin
CTRL
Trim
+Vout
+Vout
Com
Com
-Vout
-Vout
3.3V / 5V
+Vin
-Vin
CTRL
Trim
3.3V
3.3V
Com
Com
+5V
+5V
25.40
4
5
10.00
10.00
10.00
10.00
10.00
10.00
7.60
25.40
Bottom View
6
7
8
9
10
2
3
25.40
Pin Pitch Tolerance ±0.35 mm
External Output Trimming
Output can be externally trimmed by using the method
shown below.
( ) for dual output trim
[ ] for RP60-xx3.305DE only trim 3.3V
7(9) [7]
Trim Up
R
U
4(4) [4]
Trim Down
R
D
4(4) [4]
6(6) [6]
www.recom-international.com
April-2005
261