Issue: 02
Date: 2009-09-22
Specification
AXE20
Oscillator type : Crystal Oscillator in double-sealed DIL14 package
Parameter
Frequency range
Standard frequencies
Frequency stability
Overall stability (Note 2)
min.
1
1
typ.
max.
150
133
Unit
MHz
MHz
Condition
V
S
= 5 V
V
S
= 3.3 V
operating temperature range (Note 3)
0
-20
-40
-55
-55
long term (aging)
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Start-up time
Supply voltage V
S
Current consumption
(steady state)
Note 4
Operable temperature range
Storage temperature range
Enclosure (see drawing) LxWxH
Weight
Packing
ESD Sensitivity
Handling and Testing
Processing
Notes:
1.
2.
3.
4.
± 100
± 50
± 25
+70
+70
+85
+105
+125
±2
HCMOS
15
ppm
ppm
ppm
°C
°C
°C
°C
°C
ppm/year
Option I = “100”
Option I = “50”
Option I = “25”
Option II = “A”
Option II = “B”
Option II = “C”
Option II = “D”
Option II = “E”
@ 40°C
5
40
60
10
3.15
3.3
3.45
4.75
5.0
5.25
45
mA
25
mA
-45
+90
°C
-55
+125
°C
20.7x13.1x7.5 max.
mm
5
gram
Palette or tube
1500
V
In accordance with AXAN-011
In accordance with AXAN-012
pF
ns
%
ms
V
@ V
S
/2
Option III = “33”
Option III = ”50”
Option III = “33”
Option III = ”50”
IEC 60679-3 CO-02
IEC 60286-3
HBM, IEC 61000-4-2
www.axtal.com
www.axtal.com
Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Other stabilities on request
Other operating temperature ranges on request
Current consumption depending on frequency
Ordering Code:
Model (Specification) Option I Option II
AXE20
100
A
Option III Frequency [MHz]
50
12.345678
TYPE
AXE20
DATE
22/09/2009
Enclosure drawing
Pin connections
Pin # Symbol
1
N.C.
7
GND
8
RF OUT
14
Vs
Function
Not connected
Ground
RF Output
Supply Voltage
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60068
Part ...
2-17
2-20
2-58
2-27
IEC 60679-1
clause ...
4.6.2
4.6.3
Test conditions
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235
±
5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
4.6.8
4.6.7
Vibration, sinusoidal* 2-6
Endurance tests
- ageing
- extended aging
4.7.1
4.7.2
Other environmental conditions on request
TYPE
AXE20
DATE
22/09/2009