Functions of switching output MF1 PNP/MF1 NPN: position, speed, control mark Q00 (off), Q01 (on), illumination on/off, service [prefailure (dirt/LED life time), no
bar code tape, over/under temperature, out of range 0 km > position > 10 km, internal error].
Conformance Class B, PN specification V2.25.
Mechanics/electronics
Supply voltage V
s
1)
2)
3)
DC 18 V ... 30 V
1)
Limit values, reverse-polarity protected.
May not exceed or fall below U
v
tolerances.
Switching outputs MF1 short-circuit protected.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-05-02 22:08:07
Subject to change without notice
LINEAR MEASUREMENT SENSORS
Ripple
Power consumption
Initialization time
Housing material
Weight
Output current I
A
1)
2)
3)
OLM200-1009 | OLM200
≤ 5 V
pp
2)
< 5.5 W
10 s
Magnesium
Zinc
Approx. 291 g
≤ 100 mA
3)
Limit values, reverse-polarity protected.
May not exceed or fall below U
v
tolerances.
Switching outputs MF1 short-circuit protected.
Ambient data
Enclosure rating
Protection class
Electromagnetic compatibility (EMC)
Ambient temperature
Typ. Ambient light immunity
Vibration resistance
Shock resistance
1)
2)
3)
IP 65 (EN 60 529)
III
EN 61000-6-2
EN 61000-6-4
Operation: –30 °C ... +60 °C
1)
Storage: –40 °C ... +75 °C
2)
≤ 30,000 lx
3)
DIN/EN 60068-2-6, DIN/EN 60068-2-64
DIN/EN 60068-2-27
Temperatures < –20 °C with 5 min warm up time.
Max. 95 % humidity, non-condensing.
Typ. value at +25 °C ambient temperature.
2016-05-02 22:08:07 | Online data sheet
Subject to change without notice
DISTANCE SENSORS | SICK
3
OLM200-1009 | OLM200
LINEAR MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Dimensional drawing
(Dimensions in mm (inch))
OLM200, PROFINET, Ethernet, EtherCat
64.6
(2.54)
Ø
(Ø
0.2
5 .5
2)
1
2
31.9
(1.26)
8
51.8
(2.04)
8
8
3
4
5
22.2
(0.87)
6
22.2
(0.87)
7
22.2
(0.87)
24
(0.94)
89.8
(3.54)
74.4
(2.93
)
5.5
(0.22)
2
(0.08)
13.8
(0.54)
22
(0.87)
9
3
9
3.3
(0.13)
51.5
(2.03)
① Reference
axis position measurement
② Mounting
holes
③ Status
LED [status]
④ Ethernet
port 1, M12 female connector, 4-pin
⑤ EtherNet
port 2, socket M12, 4-pin
⑥ Not
assigned
⑦ Connector
M12, 5-pin
⑧ Adjustment
aid (slot)
⑨ T-slot
4
DISTANCE SENSORS | SICK
42
(1.65)
63.4
(2.50)
110.3
(4.34)
Online data sheet | 2016-05-02 22:08:07
Subject to change without notice
LINEAR MEASUREMENT SENSORS
Connection type
Connection type
OLM200-1009 | OLM200
1
2
3
4
Port 1
Port 2
① Ethernet
port 1, M12 female connector, 4-pin
② EtherNet
port 2, socket M12, 4-pin
③ Not
assigned
④ Connector
M12, 5-pin
Connection diagram
1/2
3
not connected
4
L+ (18 ... 30 V)
MF1
NPN
M (0 V)
MF1
PNP
MF2
① Ethernet,
M12 female connector, 4-pin
② Ethernet,
M12 female connector, 4-pin
③ Not
assigned
④ Connector
M12, 5-pin
Recommended accessories
Other models and accessories
www.sick.com/OLM200
Brief description
Type
Part no.
Other mounting accessories
4 pieces, Sliding nut set, M5, 4x, Included in delivery
Sliding nuts
2017550
Plug connectors and cables
Head A: male connector, M12, 4-pin, straight, D-coded
Head B: cable
Cable: PROFINET, PVC, shielded, 2 m
Head A: male connector, M12, 4-pin, angled, D-coded
Head B: cable
Cable: PROFINET, PVC, shielded, 5 m
Head A: male connector, M12, 4-pin, angled, D-coded
Head B: male connector, M12, 4-pin, straight
Cable: PROFINET, PVC, shielded, 5 m
Head A: male connector, M12, 4-pin, straight, D-coded