AC DC
65 Watts
MCS Series
•
•
•
•
•
•
•
Rugged Desktop Design
65 W
Convection Cooled
xppower.com
IP67 Ingress Protection
Wide Operating Temp. Range 40°C to +70°C
MIL STD EMC, Shock & Vibration
<0.5 W No Load Input Power
3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush
Current
•
•
•
•
90-264 VAC
47-440 Hz
1.1/0.7 A typical at 115/230 VAC
60 A typical at 230 VAC,
cold start at 25 ˚C
EN61000-3-2, class A compliant
<0.5 W
260 µA at 264 VAC/60 Hz max, 0.7/1.5 mA
typical 115/230 VAC 400 Hz.
Internal T3.15/250 V fuse in line and
neutral
General
Efficiency
Isolation
Switching Frequency
MTBF
• Up to 88% model dependent
• 4000 VAC Input to Output, 1500 VAC Input
to Ground, 500 VDC Output to Ground,
• 65 KHz typical
• 1057 kHrs, to MIL-HDBK-217F at 25 ˚C, GB
Power Factor
•
No Load Input Power
•
Earth Leakage Current
•
Input Protection
•
Environmental
Operating Temperature
• -40 ˚C to +70 ˚C derate linearly from +50 ˚C
at 2.5%/˚C to 50% load at +70 ˚C. See
derating curves.
Cooling
• Convection-cooled (see tables)
Operating Humidity
• 95% RH, non-condensing
Storage Temperature
• -40 ˚C to +85 ˚C
Operating Altitude
• 3048 m
Shock
• MIL-STD-810F, Method 516, Procedure 1
40g, 3 shocks, 6 axis, total 18 shocks,
operational
Vibration
• MIL-STD-810F, Method 514, Procedure 1
(fig 514.5C-3 composite wheeled vehicle)
5 - 500Hz, 3 axis, operational.
Ingress Protection
• IP67
Output
Output Voltage
Output Voltage Trim
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Total Regulation
Transient Response
•
•
•
•
•
•
•
•
•
12-28 VDC (see table)
No user adjustment
No minimum load required
1 s typical
50 ms
16 ms typ. at 115 VAC
±0.2% after 20 min warm up
See table
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
1% pk-pk, 20 MHz bandwidth
(1)
115-140% Vnom, recycle input to reset
110-160%
Continuous trip and restart (hiccup mode)
0.05%/˚C
EMC & Safety
Emissions
• MIL-STD-461F - Ground Army, CE102.
MIL-STD-461F - Ground Army, RE102.
Figure RE102-3 fixed wing external 2MHz -
18GHz. EN55011/22 level B conducted
EN55011/22 level A radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, class 3
Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, Class 3
• MIL-STD-461F - Ground Army, CS101,
Conducted Susceptibility, Power Leads, 30 Hz
to 150 kHz. - CS101-1 Curve #1 CS114,
Conducted Susceptibility, Bulk Cable Injection,
10 kHz to 200 MHz CS114-1 Curve #2,
CS115, Conducted Susceptibility, Bulk
Cable Injection, Impulse Excitation. CS116,
Conducted Susceptibility, Damped
Sinusoidal Transients, Cables and Power
RS103, Radiated Susceptibility, Electric Field,
2 MHz to 40 GHz. Table VII - Ground Limits
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Other Immunity
Notes
1. Measured at the end of the output cable with 10 µF electrolytic and 0.1 µF
ceramic capacitor.