350W Single Output Switching Power Supply
LRS-350
series
R33100
RoHS
(
Note.9)
■
Features
AC input range selectable by switch
Withstand 300VAC surge input for 5 second
Protections: Short circuit / Overload / Over voltage /
Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
1U low profile
Withstand 5G vibration test
LED indicator for power on
No load power consumption<0.75W
100% full load burn-in test
High operating temperature up to 70℃
O
perating
altitude up to 5000 meters
(
Note
.
8
)
■
Applications
Industrial automation machinery
Industrial control system
Mechanical and electrical equipment
Electronic instruments, equipments or
apparatus
High efficiency, long life and high reliability
3 years warranty
■
Description
LRS-350 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting
the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V,
4.2V, 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350 can work under -25~
+70
℃
with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allows
the end system to easily meet the worldwide energy requirement. LRS-350 has the complete protection
functions and 5G anti-vibration capability; it is complied with the international safety regulations such as
UL60950-1. LRS-350 series serves as a high price-to-performance power supply solution for various
industrial applications.
■
Model Encoding
LRS - 350 - 3.3
Output voltage
Output power
Series name
File Name:LRS-350-SPEC 2018-08-16
350W Single Output Switching Power Supply
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LRS-350-3.3
3.3V
60A
0 ~ 60A
198W
2.97 ~ 3.6V
LRS-350-4.2 LRS-350-5
4.2V
60A
0 ~ 60A
252W
150mVp-p
3.6 ~ 4.4V
±4.0%
±0.5%
±2.5%
5V
60A
0 ~ 60A
300W
150mVp-p
4.5 ~ 5.5V
±3.0%
±0.5%
±2.0%
LRS-350-12
12V
29A
0 ~ 29A
348W
150mVp-p
±1.5%
±0.5%
±1.0%
LRS-350
15V
23.2A
0 ~ 23.2A
348W
150mVp-p
±1.0%
±0.5%
±0.5%
24V
14.6A
0 ~ 14.6A
350.4W
150mVp-p
±1.0%
±0.5%
±0.5%
36V
9.7A
0 ~ 9.7A
349.2W
200mVp-p
±1.0%
±0.5%
±0.5%
series
LRS-350-15 LRS-350-24 LRS-350-36
LRS-350-48
48V
7.3A
0 ~ 7.3A
350.4W
200mVp-p
±1.0%
±0.5%
±0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
VOLTAGE TOLERANCE
Note.3
±4.0%
LINE REGULATION
Note.4
±0.5%
LOAD REGULATION
Note.5
±2.5%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
FAN ON/OFF CONTROL
FUNCTION (Typ.)
WORKING TEMP.
WORKING HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
NOTE
10.2 ~ 13.8V 13.5 ~ 18V
21.6 ~ 28.8V 32.4 ~ 39.6V
43.2 ~ 52.8V
1300ms, 50ms/230VAC
16ms/230VAC
47 ~ 63Hz
79.5%
6.8A/115VAC
60A/115VAC
<2mA / 240VAC
81.5%
1300ms,50ms/115VAC at full load
240 ~ 370VDC
85%
(switch on 230VAC)
88%
88.5%
89%
12ms/115VAC at full load
90 ~ 132VAC / 180 ~ 264VAC by switch
83.5%
86%
3.4A/230VAC
60A/230VAC
110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
4.6 ~ 5.4V
5.75 ~ 6.75V 13.8 ~ 16.2V 18 ~ 21V
28.8 ~ 33.6V 41.4 ~ 46.8V 55.2 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
RTH3
≧
50
℃
FAN ON,
≦
40
℃
FAN OFF
-25 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, BSMI CNS14336-1, EAC TP TC 004 approved
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +85
℃
, 10 ~ 95% RH
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25
℃
/ 70% RH
Compliance to BSMI CNS13438, EAC TP TC 020
Compliance to EAC TP TC 020
327.9K hrs min.
MIL-HDBK-217F (25
℃
)
215*115*30mm (L*W*H)
0.76Kg; 15pcs/12.4Kg/0.78CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7.The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak load is delivered
for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).
8. The ambient temperature derating of 5
/
1000m is needed for operating altitude greater than 2000m
(
6500ft
).
9. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply
under the following conditions:
a) the end-devices is used within the European Union, and
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
c) the power supply is:
- installed in end-devices with average or continuous input power greater than 75W, or
- belong to part of a lighting system
Exception:
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W;
b) symmetrically controlled heating elements with a rated power less than or equal to 200W
File Name:LRS-350-SPEC 2018-08-16