PCN: V11-016-E47540-MA
Product Change Notice
Issue Date: July 29, 2011
Change Type:
Receivers
- Change to improved mold compound
- Change to alternate photo diode source
- Change of Lead frame base material
- Change to improved mold compound
Transmitters
Description and Extent of Change:
1. Qualify improved mold compound to achieve better moisture sensitivity level (from MSL 4 to MSL 3)
Parts Affected:
HFBR-1505AFZ
HFBR-1505AZ
HFBR-1505CFZ
HFBR-1505CZ
HFBR-1506AFZ
HFBR-1506AMZ
HFBR-1515BFZ
HFBR-1515BZ
HFBR-1517Z
HFBR-1520Z
HFBR-1521Z
HFBR-1522Z
HFBR-1523Z
HFBR-1524Z
HFBR-1525EZ
HFBR-1526Z
HFBR-1527Z
HFBR-1528Z
HFBR-1531Z
HFBR-1532Z
HFBR-1533Z
HFBR-1537Z
QFBR-1548Z
QFBR-1549Z
QFBR-1551Z
QFBR-1561Z
QFBR-1570Z
QFBR-1573Z
QFBR-1585Z
QFBR-T081Z
QFBR-T501Z
QFBR-T515EZ
QFBR-T518Z
QFBR-T519Z
QFBR-T521Z
QFBR-T531Z
QFBR-TT02Z
QFBR-TT03Z
QFBR-TT06Z
QFBR-TT09Z
QFBR-521TZ
QFBR-T631Z
2. Qualify improved mold compound to achieve better moisture sensitivity level (from MSL 4 to MSL 3)
and
3. Qualify new leadframe base material to improve matching of coefficient of thermal expansion
Parts Affected:
HFBR-2505CFZ
HFBR-2505CZ
HFBR-2521Z
HFBR-2522Z
HFBR-2523Z
HFBR-2523Z-00A
HFBR-2524Z
HFBR-2531Z
HFBR-2532Z
HFBR-2533Z
HFBR-2541Z
QFBR-2548Z
QFBR-2551Z
QFBR-2573Z
QFBR-521RZ
QFBR-R521Z
QFBR-R531Z
QFBR-TR04Z
QFBR-TR05Z
QFBR-TR10Z
QFBR-5591Z
QFBR-5592Z
QFBR-5594Z
QFBR-5595Z
4. Qualify alternate photo diode supplier and improved mold compound:
Parts Affected:
QFBR-R518Z
HFBR-2510Z
HFBR-2526Z
HFBR-2536Z
Reasons for Changes:
1. Improved mold compound:
to improve moisture sensitivity level from MSL 4 to MSL 3 and to harmonize the mold compound in use.
The improved mold compound has been qualified and used in other Avago products since 2007.
2. New leadframe base material:
to improve the matching of coefficient-of-thermal-expansion. Lead frame layout remains unchanged. All
other 650nm transmitters from Avago have been qualified and shipped with this lead frame material for
more than 15 years.
3. New photodiode:
to qualify alternative photo diode supplier. The alternate supplier and its photo diode is already qualified
and used in other Avago products since 2007.
Effect of Change on Fit, Form, Function, Quality or Reliability:
Reliability qualifications have been performed to ensure product reliability before the implementation date.
Detailed product characterizations were performed to ensure product compliance to datasheet.
Effective Date of Change:
The approximate dates for sample availability, qualification completion and effective date of change for the
above changes are shown in the table below. Timing of shipment, on or after the Target Date of the changed
part will vary by part number depending on customer demand, and inventory levels.
Sample
availability
Samples are available
Qualification
completion
WW1130
Target Date
of change
WW1145
Qualification Plan:
HFBR‐1521Z
HFBR‐1527Z
HFBR‐2521Z
HFBR‐2526Z
Test
Reference
Condition
Test Points
Result
Assessment
Result
Assessment
Result
Assessment
Result
Assessment
MSL‐3
Moisture Level
Definition (MLD)
MSL – 3
JEDEC 020D.1
Moisture Level
Definition (MLD)
MSL – 4
24hrs bake @125°C,
192 +5/‐0 hrs soak at 30°C
/60%RH,
1x wavesolder 260°C/+
5°C, 10s
0/11
SAM: check
Delamination @ 0hrs and
after solder
Pass
0/11
Pass
0/11
Pass
MSL‐4
24hrs bake @125°C,
96 +5/‐0 hrs soak at 30°C
/60%RH,
1x wavesolder 260°C/+
5°C, 10s
0/11
Pass
TMCL
Temperature
Cycling
(TMCL)
MIL‐STD‐883
Method 1010
Ta = ‐40°C to +100°C
200cyc, 500cyc, and
1000cyc @ 25°C
0/33
Pass
0/33
Pass
0/33
Pass
0/33
Pass
uB85/85
TX: Unbiased
Damp Heat
(UB85/85)
MIL‐STD‐202
Method 103
RX: Biased Damp
Heat (B85/85)
Ta= 85°C, RH=85%
Vcc=5,25V,
168hrs, 500hrs and
1000hrs @ 25°C
0/22
Pass
0/22
Pass
B85/85
0/22
Pass
0/22
Pass
HTOL
High Temperature
Section 5.18 (GR‐
Operating Life
468‐CORE)
(HTOL)
Ta = 85°C, Vcc=5,25V
168hrs, 500hrs and
1000hrs @ 25°C
0/22
Pass
0/22
Pass
0/22
Pass
0/22
Pass
Mechanical Shock
(MS)
1
MIL‐STD‐883
Method 2002B
1500g (peak), 0.5ms,
5 pulses/surface, 6
surfaces
Post MS/MV
20 – 2000HZ, 20 G
4min/cycle, 4cycle/axis,
3 axis
0/11
Pass
0/11
Pass
0/11
Pass
0/11
Pass
MS/MV
Mechanical
Vibration (MV)
1
MIL‐STD‐883
Method 2007A
0/11
Pass
0/11
Pass
0/11
Pass
0/11
Pass
___________________________________________________________________________________________
These changes have been reviewed and approved by Avago Technologies engineers and managers per Avago
Technologies procedure: Change Control and Customer Notification, A-5962-6052-80.
Please contact your Avago Technologies field sales engineer or Contact Center (http://www.avagotech.com/contact/ ) for
any questions or support requirements. Please return any response as soon as possible, but not to exceed 30 days.