double-conversion UPS support for server, network and telecommunications equipment. Maintains
battery-derived AC output during blackouts with active, full-time power conditioning. Fault-tolerant auto-bypass
prevents unexpected service interruptions during overload or internal fault conditions. Single all-in-one housing
installs in 4 rack spaces (4U). Upright tower and two post rackmount installation supported with optional
accessories. Maintains full-time sine wave output within 3% of selectable 208/120 or 240/120V AC. Corrects
brownouts and overvoltages from 65V to 140V (L-N). Expandable runtime with optional external battery packs.
Converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC output with
enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems
not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat
L6-20R, 5-15/20R & Hardwire
outputs
Package Includes
SU8000RT4U Smart Online UPS
SUPDM8K Detachable PDU with
Manual Bypass Switch
PowerAlert software and
complete cabling
4 post rackmount installation
brackets
output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include combination DB9 RS-232 enabled and dry
contact serial port, enhanced USB port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto
shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions
via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Supports Emergency Power Off (EPO) via built-in interface. Front
panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions. LED/LCD display panel easily rotates for viewing in
rackmount or tower configurations. Split phase 4 conductor hardwire input. UPS supported outlets include two L6-30R, two L6-20R and 4 low voltage
5-15/20R. Hardwire output is also supported. Hardwire connections and outlets are mounted on a detachable backplate with manual bypass switch to enable
hot-swappable UPS replacement without powering off connected equipment. Internal batteries and optional external battery packs are field replaceable and
hot swappable. Attractive all-black color scheme. $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).
Features
True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
8000VA/5600 watt output power capacity with dual voltage output of 208/120 or 240/120V
1/6
4U all-in-one high power density housing supports rackmount installation in only 4 rack spaces
Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic
distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Hardwire input/output connections and output receptacles are mounted on a detachable backplate with manual bypass switch to enable hot-swappable
UPS replacement without powering off connected equipment
Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical
servers, networking and telecommunications equipment
Maintains output within 3% of selected 208/120 or 240/120V nominal voltage during brownouts and overvoltages
Supports connected equipment during blackouts for 12/5 minutes at half/full load levels, runtime is further expandable with optional external battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232 and dry contact
messaging. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number
of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control
Built-in Emergency Power Off (EPO) interface with cable
Includes hardwire output and 8 output receptacles (2 L6-30R, 2 L6-20R, 4 NEMA 5-15/20R), all of which are available for simultaneous use
Split phase, 4 conductor hardwire connection (featured on included detachable PDU).
Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions
Front panel switches enable power on/off control, self-test and alarm cancel functions
Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures
Optional 2-9USTAND set of tower stands supports upright tower installation
Optional 2POSTRMKITHD accessory enables 2 post rackmount installation
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Specifications
OUTPUT
8,000VA / 5600W (240V), 7200VA / 5600W (208V); Supports up to 105% load continuously in double conversion
mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode
operation to support equipment directly from mains power; Double conversion mode is automatically restored as
the overload is cleared
8000
8
5600
5.6
0.7
3:1
120V; 208V; 240V
Output Capacity Details
Output Volt Amp Capacity (VA)
Output kVA Capacity (kVA)
Output Watt Capacity (Watts)
Output kW Capacity (kW)
Power Factor
Crest Factor
Nominal Output Voltage(s)
Supported
2/6
Nominal Voltage Details
Frequency Compatibility
Frequency Compatibility Details
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
Output Receptacle Details
Output Circuit Breakers
Output AC Waveform (AC Mode)
Output AC Waveform (Battery Mode)
240/120V or 208/120V split phase output
60 Hz
Output frequency regulation +/- 0.05Hz (free running)
+/- 3%
+/- 10%
+/- 3%
(4) 5-15/20R; (2) L6-20R; (2) L6-30R; Hardwire
Supports 208/120V or 240/120V hardwire output (L1, L2, N, G)
20A branch rated breakers (x4) protect 1 5-15/20R outlet each, 20A double pole breakers (x2) protect one L6-20R
each, L6-30R outlets are unbreakered
Pure Sine wave
Pure Sine wave
INPUT
Rated input current (Maximum Load)
Nominal Input Voltage(s) Supported
UPS Input Connection Type
UPS Input Connection Description
Recommended Electrical Service
Input Phase
34A
208V AC / 120V AC (4 wire split single phase); 240V AC /120V AC (4 wire split single phase)
Hardwire
4 wire split-phase input (L1, L2, N, G)
40A 208/120V or 240/120V Split Phase
Single-Phase
BATTERY
Full Load Runtime (min.)
Half Load Runtime (min.)
Expandable Battery Runtime
External Battery Pack Compatibility
DC System Voltage (VDC)
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery Access
Battery Replacement Description
5 min. (5600w)
12 min. (2800w)
Supports extended runtime with optional external battery packs
BP192V1037C-1PH
;
BP192V12-3U
;
BP192V1407C-1PH
;
BP192V557C-1PH
;
BP192V787C-1PH
;
BP192V5RT2U
(limit 1)
192
Less than 6 hours from 10% to 80% (typical, full load discharge)
RBC9-192
Front panel battery access door
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
3/6
Voltage Regulation Description
Overvoltage Correction
Undervoltage Correction
Online, double-conversion power conditioning
Corrects overvoltages to 140 (measured L1-N : L2-N)
Corrects undervoltages to 65 (measured L1-N : L2-N)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats
Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass
switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without
disrupting output power
Alarm cancel switch
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options
Switches
Alarm Cancel Operation
Audible Alarm
LED Indicators
SURGE / NOISE SUPPRESSION
UPS AC Suppression Response
Time
EMI / RFI AC Noise Suppression
AC Suppression Response Time
Instantaneous
Yes
Instantaneous
PHYSICAL
Included Mounting Accessory
Description
Installation Form Factors Supported
with Optional Accessories
Primary Form Factor
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
Installed Whole System Maximum
Rack Depth (in.)
Installed Whole System Maximum
Rack Depth (cm)
Rack Height (U Spaces)
UPS Power Module Weight (lbs.)
UPS Power Module Weight (kg)
UPS Dimensions Details
UPS Shipping Dimensions (hwd / in.)
4 post rackmount installation accessories included
2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
Rackmount
7 x 17.5 x 32.6
17.8 x 44.4 x 82.7
32.6
82.7
4
177
80.4
Installed Whole System Maximum Rack Depth refers to the installed depth with the included Bypass PDU attached
to the UPS power module
13 x 23 x 37
4/6
UPS Shipping Dimensions (hwd /
cm)
Shipping Weight (lbs.)
Shipping Weight (kg)
Cooling Method
UPS Housing Material
33 x 58.4 x 94
212
96.2
Fans
Steel
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
AC Mode Efficiency Rating (100%
Load)
Operating Elevation (ft.)
Audible Noise
Operating Elevation (m)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
2353.3
89%
0-3000m (0 to 10,000 ft.)
60 dBA at front side 1 meter
0-3000 m
COMMUNICATIONS
Communications Interface
Network Monitoring Port Description
PowerAlert Software
Communications Cable
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
RS232 and contact closure communications are supported on one DB9 port
Included
USB and DB9 cabling included
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
No transfer time (0 ms.) in online, double-conversion mode
65V (L1-N:L2-N)
140V (L1-N:L2-N)
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS Features
Green Energy-Saving Features
Cold-start operation supported
Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module;
Hot swappable batteries
High efficiency economy mode operation; Schedulable daily hours of economy mode operation