AC/DC Converter
LD03-10BxxR2 Series
3W, AC-DC converter
FEATURES
Universal input range:85~264VAC/100~370VDC
Excellent ripple and noise performance:
LD03-10BxxR2 ---- a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC input
voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, EMC and Safety
specifications meet the international IEC61000, UL60950 and EN60950 standards, and widely used in medical treatment, industrial,
electricity, instruments, telecommunication and civil applications. For harsh EMC environment, the application circuit in the datasheet is
strongly recommended.
CB
50mV (Typ.)
Compact size, high power density
Protection of output over-voltage, output short
circuit, over-current
Meets
IEC60950,
UL60950, EN60950 standards
RoHS
Selection Guide
Certification
Model
LD03-10B03R2
LD03-10B05R2
UL/CE
LD03-10B09R2
LD03-10B12R2
LD03-10B15R2
LD03-10B24R2
3W
Output Power
2.3W
Nominal Output Voltage
and Current (Vo/Io)
3.3V/700mA
5V/600mA
9V/330mA
12V/250mA
15V/200mA
24V/125mA
Efficiency
(230VAC/%,Typ.)
66
74
75
77
77
78
Max. Capacitive Load
(uF)
6000
6000
1500
1500
1000
330
Input Specifications
Item
Input Voltage Range
Input frequency
Input current
Inrush current
Leakage current
Recommended External Input Fuse
Hot Plug
110VAC
230VAC
110VAC
230VAC
Operating Conditions
AC input
DC input
Min.
85
100
47
--
--
--
--
Typ.
--
--
--
65
30
10
20
Max.
264
370
63
--
--
--
--
Unit
VAC
VDC
Hz
mA
A
0.1mA RMS typ. 230VAC/50Hz
1A/250V, slow fusing
Unavailable
Output Specifications
Item
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise*
Temperature Drift Coefficient
Stand-by Power Consumption
Short Circuit Protection
Over-current Protection
Over-voltage Protection
3.3/5VDC output
9VDC output
Operating Conditions
3.3V output
Others
Full load
10%-100% load
20MHz bandwidth (peak-peak value)
Min.
--
--
--
--
--
--
--
Typ.
±3
±2
±0.5
±1
50
±0.02
0.3
Max.
--
--
--
--
100
--
--
mV
%/°C
W
%
Unit
Continuous, self-recovery
≥110%Io
self-recovery
≤7.5VDC
≤12VDC
2015.04.17-A/1
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
Over-voltage Protection
Min. Load
Power-off Holding Time
230VAC input
12/15VDC output
24VDC output
1
--
--
50
≤20VDC
≤30VDC
--
--
%
ms
Note: *Parallel line test method is adopted to test the ripple and noise, please see
AC-DC Converter Application Notes
for specific operation methods.
General Specifications
Item
Isolation Voltage
Operating Temperature
Storage Temperature
Case Temperature
Storage Humidity
Welding Temperature
Switching Frequency
Power Derating
Safety Standard
Safety-regulated Certification
Safety Class
MTBF
+55℃~+70℃
Wave-soldering
Manual-welding
--
2.0
EN60950/UL60950
CLASS
Ⅱ
MIL-HDBK-217F@25°C > 300,000 h
Input-output
Operating Conditions
Test time: 1min
Min.
3000
-25
-25
--
--
Typ.
--
--
--
--
--
Max.
--
+70
+105
+95
95
%RH
°C
Unit
VAC
260±5℃; time:5~10s
360±10℃; time:3~5s
115
--
--
--
kHz
%/°C
IEC60950,EN60950,UL60950
Physical Specifications
Casing Material
Package Dimensions
Weight
Cooling method
Black flame-retardant and heat-resistant plastic (UL94-V0)
37.00*24.50*18.00 mm
25g(Typ.)
Free convection
EMC Specifications
CE
EMI
RE
ESD
RS
EFT
EMS
Surge
CS
PFM
Voltage dips, short interruptions
and voltage variations immunity
CISPR22/EN55022, CLASS A
CISPR22/EN55022, CLASS B (See Fig. 2 for recommended circuit)
CISPR22/EN55022, CLASS A
CISPR22/EN55022, CLASS B (See Fig. 2 for recommended circuit)
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
IEC/EN61000-4-4
IEC/EN61000-4-5
IEC/EN61000-4-5
IEC/EN61000-4-6
IEC/EN61000-4-8
IEC/EN61000-4-11
Contact ±6 kV / Air ±8 kV
10V/m
± 2kV (See Fig. 1 for typical application circuit)
± 4kV (See Fig. 2 for recommended circuit)
±1 kV (See Fig. 1 for typical application circuit)
±2 kV /±4 kV(See Fig. 2 for recommended circuit)
10 Vr.m.s
10A/m
0%-70%
perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria A
perf. Criteria A
perf. Criteria B
2015.04.17-A/1
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
Product Characteristic Curve
Output Power Percent(%)
Output Power Percent(%)
Temperature Derating Cur ve
100
70
50
20
-25
55
70
Ambi ent temperature .(
℃
)
Input voltage
:
100~240VAC
120~340VDC
Input Voltage Derating Cur ve
100
80
76
50
20
85
100
100
240 264
120
340 370
Input Voltage
VAC
VDC
Ambient temperatu re:2 5℃
Note:
①Input
voltage should be derated based on temperature derating when it is 85~100VAC/240~264VAC/100~120VDC/340~370VDC;
②This
product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
Efficiency Vs Input Voltage(Full Load)
90
85
90
85
80
Efficiency Vs Output Load(Vin=230VAC)
LD03-10B24R2
LD03-10B12R2
LD03-10B05R2
Efficiency(%)
75
70
65
60
85
110
220
240
LD03-10B24R2
LD03-10B12R2
LD03-10B05R2
Efficiency(%)
80
75
70
65
60
55
50
45
264
40
10
20
30
40
50
60
70
80
90
100
Input Voltage(VAC)
Output Power Percentage(%)
Design Reference
1. Typical application circuit
AC (L)
FUS E
AC (L)
MOV1
+Vo
C1
C2
TVS
RL
AC/DC
AC ( N)
-Vo
+
AC (N )
Fig. 1: Typical application circuit
Model
LD03-10B03R2
LD03-10B05R2
LD03-10B09R2
LD03-10B12R2
LD03-10B15R2
LD03-10B24R2
C1(μF)
1
C2(μF)
150
150
120
120
120
68
TVS tube
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
Note:
Output filtering capacitor C2 is electrolytic capacitor, it is recommended to apply electrolytic capacitor with high frequency and low resistance. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitance withstand voltage derating should be 80% or above. C1 is
ceramic capacitor, which is used to filter high-frequency noise. External input MOV1 is recommended to use S14K350. TVS is a recommended component to
protect post-circuits if converter fails.
2. EMC solution-recommended circuit
Can use MORNSUN’s FC-LX1D
FUSE
A C(L)
CY1
MOV 1
CX
CY2
L DM
L CM
A C(L)
+Vo
C1
C2
TVS1
RL
+
AC/DC
-Vo
A C(N )
A C(N )
Fig 2: EMC application circuit with higher requirements
2015.04.17-A/1
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
Fig 3: Recommended EMC circuit-PCB layout
Suggestions for safety regulation and wiring width: wire width
≥3mm,
distance between wires
≥6mm,
and distance between wire and
ground
≥6mm
Element model
MOV1
CX
LDM
LCM
CY1
CY2
FUSE
FC-LX1D
Recommended value
S14K350
0.1μF/275VAC
4.7uH/2.0A
10mH ~30mH,recommended to use MORNSUN’s FL2D-Z5-103
1nF/400VAC
1nF/400VAC
1A/250V, slow fusing, necessary
2KV/4KV EMC filter
3. For more information please find the application note on
www.mornsun-power.com
Dimensions and Recommended Layout
THIRDANGLEPROJECTION
16
FrontView
14
18.00[0.709]
1
3
13
4.10[0.161]
30.48[1.200]
5.08[0.200]
0.60[0.024]
∅
1.10[
∅
0.043]
Note:Grid2.54*2.54mm
1
3
BottomView
16
13
Pin-Out
24.50[0.965]
17.78[0.700]
14
Pin
1
3
13
Function
AC(L)
AC(N)
NC
-Vo
+Vo
5.08[0.200]
37.00[1.457]
Note:
Unit:mm[inch]
Pindiametertolerances:±0.10[±0.004]
Generaltolerances:±0.50[±0.020]
14
16
1104007201-A0
2015.04.17-A/1
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LD03-10BxxR2 Series
Note:
1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58200055;
2. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting
nominal voltage and outputting rated load;
3.
4.
5.
6.
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technician for specific information;
We can provide product customization service;
The product specification may be changed at any time without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2015.04.17-A/1
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation