MODEL TL-5930
International size reference: D, ER32L615
TECHNICAL DATA
(Typical values @+ 25ºC for batteries stored for one year or less)
Nominal capacity @ 4 mA, to 2 V
19 Ah
Rated voltage
3.6 V
Maximum recommended continuous current
230 mA
Maximum pulse current capability
500 mA
Weight
93 g (3.28 oz)
Volume
51 cc
Operating temperature range
-55 ºC to +85 ºC
Li metal content
approx. 5 g
U.L. Component Recognition, MH 12193
Volts
4.0
DISCHARGE CHARACTERISTICS @ +25ºC
3.5
3.0
2.5
2.0
33
Ω
~100 mA
(9.0 Ah)
56
Ω
~60 mA
(13.1 Ah)
180
Ω
330
Ω
910
Ω
~20 mA ~10 mA
~4 mA
(16.9 Ah) (18.2 Ah) (19.0 Ah)
18 kΩ
~200
µA
(15.4 Ah)
1.5
TERMINATIONS & ORDERING NO.
SUFFIX- /S STANDARD
15-5930-21500
15-5930-31500
SUFFIX- /T SOLDER TABS
1.0
1
10
100
1000
10000
100000
Hours
Volts
3.7
3.5
3.3
3.1
2.9
2.7
2.5
2.3
-50
50
µ
A
VOLTAGE VS. TEMPERATURE
Ah
20.0
18.0
0 °C
25 °C
CAPACITY VS. CURRENT
100
µ
A
0.5 mA
2 mA
20 mA
16.0
14.0
12.0
10.0
8.0
55 °C
72 °C
100 mA
6.0
4.0
2.0
-30
-10
10
30
50
70
90
ºC
0.1
1
10
-30 °C
100
mA
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
Rev. B 01/06
Page 1 of 2
TL-5930
CELL FEATURES
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
Low self discharge rate
10 years shelf life
Bobbin construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
Restricted for transportation (Class 9 worldwide)
Non-restricted within the US
Volts
3.4
MAIN APPLICATIONS
Utility meters (elect., water & gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power (ULP) devices
Others
VOLTAGE RESPONSE AFTER STORAGE
After 2 years
After 1 year
After 5 years
3.2
After 8 years
3.0
After 10 years
STORAGE CONDITIONS
Cells should be stored in a clean
& dry (less than 30 % RH) area
Temp. should not exceed +30 ºC
2.8
Pulse applied: 60 mA for 1 sec
Storage: RT
Background current: None
2.6
2.4
0
200
400
600
800
1000
1200
msec
For updated information please visit
our website
www.tadiranbat.com
Volts
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
0
20
VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
Volts
3.6
3.4
3.2
3.0
After 8 years
After 10 years
VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
2.8
2.6
2.4
2.2
Pulse applied: 60 mA for 100 msec
Temperature: RT
Background current: 100
µA
0
20
40
60
80
After 8 years
Pulse applied: 60 mA for 100 msec
Temperature: RT
Background current: 50
µA
40
60
80
100
120
msec
100
120
msec
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
Rev. B 01/06
Page 2 of 2