300W ~ 400W AC-DC ACTIVE PFC SWITCHING POWER SUPPLY
PRL1201D DUAL OUTPUT SERIES
FEATURES:
◆
400W convection cooling with 1U height
◆
Design meets IEC/EN/UL60950-1 Latest Edition
◆
Power Factor Corrected to EN61000-3-2 class D
◆
High Quality & Reliable Component Usage
◆
5/ 12/ 24V Dual Output Optional Combinations
◆
Full Range AC Input
U Type (U-Chassis only):
5(W) x 8(L )x 1.6(H) inches.
PRODUCT SPECIFICATIONS:
Input Voltage:
90 ~ 264Vac full range, 47 ~ 63Hz.
Input Current:
6A at 90VAC full load.
Inrush Current:
70A peak maximum.(Measuring at 230VAC and full
load cold start.)
Power Factor Correction:
Pass EN61000-3-2 class D
Transient Response:
Returns to within 1% in less than 2.5mS for a
50% load change and the peak transient does not excess 5%.
Overshoot:
Turn-on & turn-off not exceed 5% over nominal voltage.
Efficiency:
80% minimum (Measuring at 115V and full load)
Turn On Delay:
2 second maximum at 115 VAC.
Hold Up Time:
16 m sec. minimum at 115VAC and 75% of rated
maximum load.
Adjustability:
Output user adjustable +/-5% minimum.
Remote On-Off:
Designated as
RSW
on the CN3, requires a low
signal to inhibit output.
Power Supply On:
When the Bi-color LED emit green light that
indicates the supply is operating. When any protection is occurred or
RSW is applied a low signal, the Bi-color LED will emit orange light.
Power Good:
Designated as PG on CN3. This signal will go high
100-500 Msec after the output reaches the regulation limit. It goes
low at least 1 Msec before loss of regulation and has ability to sink
100mA.
Input Circuit Protection (primary):
One T6.3A/250V fuse inserted.
Input Voltage Protection:
Power shut down under 80 +/-10Vac, and
recovered over 90 Vac.
Over-Power Protection:
110~140% of the rated output current and
recovers automatically.
Over-Voltage Protection:
Latching down will occur when output
voltage exceed 130% max., and recycle AC input to reset.
Over Temp. Protection:
Protected at ambient 110 +/- 5
℃;
Auto-
recovery.
Short Circuit Protection:
Trip without damage and auto-recovery.
Operating Temperature:
0℃ to +50℃
Switching Frequency:
PFC 60K Hz; PWM 27K Hz.
Storage Temperature:
-20 to +85 degrees C.
Operating Humidity:
5% to 90% RH, Non-condensing.
Storage Humidity:
5% to 95% RH, Non-condensing.
Vibration:
Frequency 5 to 50 Hz, acceleration +/-7.35 M/(SxS) on
X,Y and Z Axis.
EMC:
EN55022 class B conducted / radiated, EN61000-3-2,
EN61000-3-3; EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-
4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-11).
Safety:
Approved UL60950-1, CSA C22.2 No. 950-95, EN60950 and
CB certificate available
Leakage Current:
< 500uA at 240Vac
HI-POT Test:
1500 VAC between input line and chassis (10mA AC
cut off current); 3000VAC between primary and secondary windings;
Primary to core 1500VAC. All for 3 sec.
Grounding Test:
Apply 25 A from ground pin to the earthed
connection point. Maximum allowable resistance is 0.1ohm.
Warranty:
2 years.
MTBF:
100000 Hrs (according to MIL-HBK-217F) at 30℃.
Burn in:
45 +/- 5 degree C for 1 hour @230Vac with full load.
Weight:
1KG
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.
ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw
Tel:+886-2-29180118
Fax:+886-2-29181465
We Supply the Power Customers Need
ISO9001
OUTPUT VOLTAGE / CURRENT RATING CHART:
Measured at output power connector.
Model Number
PRL1201D-0512
PRL1201D-0524
PRL1201D-1224
Output Voltage
V1: +5V
V2: +12V
V1: +5V
V2: +24V
V1: +12V
V2: +24V
Output Current
Max. Load Convection
35A
16.67A
35A
8.33A
25A
12.5A
Total Regulation
+/- 5%
+/- 5%
+/- 5%
+/- 5%
+/- 5%
+/- 5%
Ripple & Noise
+/-1%
+/-1%
+/-1%
+/-1%
+/-1%
+/-1%
NOTE:
* PRL1201D series are designated as PRL1201D-y where y can be 0512,0524,1224
* 10% minimum load is required for all outputs to maintain the ripple and regulation Output is fully isolated
* Total combined power of V1 and V2:
400W Max. for PRL1201D-1224 convection cooling.
300W Max. for other models convection cooling.
* Ripple and noise is measured from 10KHZ to 20MHz bandwidth at output terminals with parallel 0.1µF ceramic and
22µF electrolytic capacitors.
OUTLINE DRAWING:
PRL1201DU Series (U-Chassis Type): 8(L) x 5(W) x 1.6(H)inches; Weight: 1KG
C
B
C
B
CN3
RSW
RTN
PG
B: MOUNTING HOLE 8 PLACE
6-32 UNC(Zn-plated)
SCALE 4:1
B
C
B
C
CN3
OPTIONAL CONNECTOR
MOLEX PART NO.
09-50-3141 (14 PINS)
V2
CN1
RTN
RTN
V2
MOLEX PART NO.
09-50-3071
(7 PINS, 5 USED)
PIN NO.3,6 NC
CN2
V1
C
B
C
B
TERMINAL BLOCK
3PINS 9.5mm CENTER
TERMINAL BLOCK
6PINS 9.5mm CENTER
B
C
B
C
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.
V1
N
L
C:MOUNTING HOLE 8 PLACE
M4X0.7 (BRASS)
SCALE 4:1
ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw
Tel:+886-2-29180118
Fax:+886-2-29181465
We Supply the Power Customers Need
ISO9001
I/O Connector pin assignment:
AC Input Connector(CN1):
Mating Molex Part No. 09-50-3071 or equivalent (7 pin,5 used)
Howder Terminal block Part No. HD-121-3P
Output Connector (CN2):
Howder Terminal block Part No. HD-121-6P
Mating Molex Part No. 09-50-3141 (14 pin)
Output Pin Assignment: (See below table).
Logic signal connectors (CN3):
Mating JST XHP-3 or equivalent (CHYAO SHIUNN JS-1001-03)
Mating Pins: JST SXH-002T-P0.6 FOR AWG 30 TO 26
PIN1: PG PIN2: RTN PIN3: RSW
Mounting Inserts:
6-32, M4 4Places individually with
maximum penetration 0.15” on bottom side and 0.25” on
both side
V1+
MOLEX
HOWDER
PINS 1-5
PINS 1-2
V0-
PINS 6-11
PINS 3-5
V2+
PINS 12-14
PINS 6
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.