EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS011S26WD30CY

Description
SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.6mm, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size229KB,4 Pages
ManufacturerC&K Components
Environmental Compliance  
Download Datasheet Parametric View All

LCS011S26WD30CY Overview

SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.6mm, PANEL MOUNT, ROHS COMPLIANT

LCS011S26WD30CY Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K Components
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke5.6 mm
Actuator typeSIMULATED LEVER
body width6.4 mm
body height15.95 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load.1A@250VAC
Maximum contact current (AC)0.1 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Manufacturer's serial numberLCS
Installation featuresPANEL MOUNT
Maximum operating force1.47 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel4.6 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 125/250 V AC
and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE: –40ºC to +125ºC without wire
–40ºC to +85ºC with wires
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Models Available
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 125/250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
0.45 mm short lever
T05
5.05 mm short lever
T07
7.05 mm short lever
T13
13.15 mm lever
T19
20.95 mm lever
T28
28.35 mm lever
T43
43.55 mm lever
S26
6.25 mm simulated lever
A05
4.85 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
Why do we write =0 when assigning a variable a value of 0, but write =0xffffffffu when assigning it a value of 0xffffffff?
Why is it that when assigning a variable a value of 0, we can just write *ram = 0, but when assigning it a value of 0xffffffff, we need to write *ram = 0xffffffffu? The following is the specific code/...
深圳小花 MCU
Learning PCB
There are many professionals. I have learned a lot....
novemberman PCB Design
TMDSLCDK138 board about PRU part program
I can't find any PRU routines in the RTOS and BIOS_SDK provided by TI. I found the URL http://www.ti.com/tool/pru-swpkg, but the information there is no longer available. Where can I find official inf...
alasijia DSP and ARM Processors
NI Taobao brand store, Double Eleven hot items return
NI Taobao Brand Store Authentic products in stock, Double Eleven hot items are back Hot deals, breaking the bottom price Copy the Taobao password and enter the store immediately 5(Gx6gXDJJrZu)/NI year...
eric_wang Integrated technical exchanges
ESP32-S2-Kaluga-1 Kit v1.3
Note: This is V1.3 Earlier versions: ESP32-S2-Kaluga-1 kit v1.2 ESP32-S2-Kaluga-1 Kit v1.3ESP32-S2-Kaluga-1 v1.3 is a development kit from Espressif that can be used for the following purposes:Demonst...
火辣西米秀 Domestic Chip Exchange
Solution to MotionFX getting stuck when executing MotionFX_initialize(); function
I was recently using the MotionFX sensor data integration library and a project generated by STM32CubeMX. During testing, the code stopped executing at MotionFX_initialize();. Later I found that it wa...
littleshrimp MEMS sensors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号